About
EMC S.r.l., trading as EMC Lab, operates from Via Greto di Cornigliano in the western industrial belt of Genoa, and publishes a chamber specification in more detail than almost any laboratory in this directory. Its semi-anechoic shielded chamber measures 8.5 metres long by 6.1 wide by 5.8 high internally, covers 26 MHz to 6 GHz, and is qualified to figures the company states openly: shielding effectiveness above 120 dB, normalised site attenuation within plus or minus 4 dB, and field uniformity of minus zero to plus 6 dB across 75 per cent of the measurement points - the three numbers that actually determine whether a chamber's results are defensible. The usable quiet zone is 2 metres in diameter and 2 metres high, served by a turntable and antenna mast, and the main door is a 2 by 2 metre automatic sliding type with a synchronised access ramp, so wheeled and palletised equipment can be rolled straight in rather than lifted. Alongside electromagnetic compatibility measurement on both apparatus and complete systems, the laboratory performs environmental electromagnetic field measurement - assessing emission levels in occupied environments rather than from products, a distinct service line - plus electrical safety, climatic and mechanical testing. It publishes an ACCREDIA accreditation page and an ISO 9001 certification but does not state its accreditation number, so confirm the accredited scope before booking. Specialisations are large and palletised equipment EMC, environmental electromagnetic field surveys, and combined EMC with electrical safety, climatic and mechanical testing for the Ligurian industrial base.
Accreditations
| Accreditation |
|---|
| ISO/IEC 17025 |
| EMC Directive 2014/30/EU |
Testing Services
| Test Type | Applicable Standards |
|---|---|
| Radiated Emissions | CISPR 11, EN 55011, CISPR 32, EN 55032, CISPR 14-1, EN 55014-1, CISPR 16-1-4, CISPR 16-2-3, EN 61000-6-3, EN 61000-6-4 |
| Conducted Emissions | CISPR 11, EN 55011, CISPR 32, EN 55032, CISPR 14-1, EN 55014-1, CISPR 16-1-2, CISPR 16-2-1, EN 61000-6-3, EN 61000-6-4 |
| Radiated Immunity | IEC 61000-4-3, EN 61000-4-3, EN 55035, EN 55014-2, EN 61000-6-1, EN 61000-6-2 |
| Conducted Immunity | IEC 61000-4-6, EN 61000-4-6, EN 55035, EN 55014-2, EN 61000-6-1, EN 61000-6-2 |
| ESD | IEC 61000-4-2, EN 61000-4-2 |
| EFT/Burst | IEC 61000-4-4, EN 61000-4-4 |
| Surge Immunity | IEC 61000-4-5, EN 61000-4-5 |
| Harmonics & Flicker | IEC 61000-3-2, EN 61000-3-2, IEC 61000-3-3, EN 61000-3-3, IEC 61000-3-11, IEC 61000-3-12 |
| Voltage Dips/Interrupts | IEC 61000-4-11, EN 61000-4-11, IEC 61000-4-29 |
| Power Frequency Magnetic Field | IEC 61000-4-8, EN 61000-4-8 |
| Pre-Compliance Testing | CISPR 11, CISPR 32, IEC 61000-4-3, EN 61000-6-2 |
| Product Safety | EN 62368-1, EN 60335-1, EN 61010-1, EN 60204-1 |
| Environmental Testing | IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-14, IEC 60068-2-30, IEC 60068-2-78, IEC 60529 |
| Mechanical Testing | IEC 60068-2-6, IEC 60068-2-27, IEC 60068-2-31 |
Certifications / Marks
| Certification |
|---|
| CE |
| ISO 9001 |
Industries Served
| Industry |
|---|
| Industrial Equipment |
| Energy & Power |
| Consumer Electronics |
| Household Appliances |
| Information Technology |
| Medical Devices |
Major Equipment
| Equipment |
|---|
| Semi-anechoic shielded chamber 8.5 x 6.1 x 5.8 m internal, 26 MHz - 6 GHz |
| Shielding effectiveness above 120 dB |
| Normalised site attenuation within +/-4 dB |
| Field uniformity -0/+6 dB across 75% of points |
| Quiet zone 2.0 m diameter x 2.0 m high |
| 2.0 x 2.0 m automatic sliding door with synchronised access ramp |
| Turntable and antenna mast |
| EMI receiver |
| Spectrum analyser |
| LISN |
| CDN |
| ESD simulator |
| EFT/burst generator |
| Surge generator |
| Harmonics and flicker analyser |
| RF immunity amplifier and antennas |
| Environmental electromagnetic field survey probes |
| Electrical safety test equipment |
| Climatic and mechanical test facilities |