EMC Converter Tools for Engineers
Focused EMC converter tools for the unit changes that show up on every chamber plot: conducted dBm ↔ dBµV, radiated dBµV/m ↔ V/m, antenna factor, distance, and a quick CISPR / FCC margin check. Pick the calculator that matches the measurement — each tool does one job clearly.
Conducted emissions
dBm ↔ dBµV
ConverterConvert between dBm and dBµV at any system impedance (50 Ω, 75 Ω, or custom).
Open calculator →
Conducted units
ConverterConvert conducted emission units between dBµV, dBµA, dBm, and dBmA at a LISN impedance.
Open calculator →
RF power
ConverterConvert RF power between dBm, watts, dBW, and conducted voltage (dBµV) at a given impedance.
Open calculator →
RF voltage
ConverterConvert RF voltage between dBµV and linear units (µV, mV, V), plus peak, RMS, and peak-to-peak for sine waves.
Open calculator →
Radiated field
dBµV/m ↔ V/m
ConverterConvert electric field strength with a dBµV/m to V/m converter — and the reverse — for radiated EMC plots and immunity levels.
Open calculator →
E-field units
ConverterConvert radiated electric field strength between logarithmic (dBµV/m) and linear units (V/m, mV/m, µV/m).
Open calculator →
E ↔ H field
ConverterConvert between electric field (E) and magnetic field (H) strength under plane-wave far-field conditions.
Open calculator →
Power density
ConverterConvert electric field strength to power density (W/m² or mW/cm²) for far-field radiated emissions.
Open calculator →
H-field units
ConverterConvert magnetic field strength between dBµA/m, A/m, Tesla, Gauss, and pT.
Open calculator →
Distance extrapolation
ConverterExtrapolate radiated field strength between measurement distances using the 20 dB/decade free-space rule.
Open calculator →
Receiver + AF → Field
WorkflowConvert receiver readings to field strength using antenna factor, cable loss, and system impedance.
Open calculator →
Limits & margin
RF reference
What an EMC converter is for
An EMC converter is a unit translator for the four languages that show up on a typical test bench: conducted voltage (dBµV), analyzer power (dBm), linear field strength (V/m), and logarithmic field strength (dBµV/m). The physics is the same disturbance; the instrument, the LISN, and the limit table each picked a different reference.
Engineers use these tools when a customer spec mixed units, when a pre-scan plot is in dBµV/m and an immunity level is in V/m, or when a spectrum-analyzer marker in dBm has to be compared with a CISPR conducted limit in dBµV. The pages that rank—and the ones that stay bookmarked—are the ones that show the formula next to the calculator, not a blank widget.
How to pick the right tool
Start with the measurement you already have. Conducted LISN or analyzer readings belong in the dBm ↔ dBµV and conducted-emissions converters. Radiated receiver readings that still need antenna factor belong in the radiated field calculator. If you already have field strength and only need dBµV/m to V/m (or the reverse), use that dedicated converter. Distance mismatches between 3 m and 10 m limits go to the extrapolation tool. A finished dBµV/m number can be dropped into the emission limit checker for a simplified CISPR 32 or FCC Part 15B margin.
None of these calculators replace an accredited test report. They exist so you can catch a unit error before you book chamber time—or explain a plot to a designer who lives in volts, not decibels.
Frequently asked questions
Quick answers about using this calculator