EMC Latest

EMC Testing Labs in Georgia – Accredited Facilities

Georgia is the Southeast booking hub when a team does not want to fly to Florida or the Carolinas. Atlanta-area accredited EMC testing laboratory sites handle commercial FCC/CE work, industrial controls, and an increasing mix of EV and aerospace hardware.

2

Listed labs

2

Labs with listed accreditations

6

Metro areas

Accredited EMC labs in Georgia

2 listed facilities, 2 with accreditations on file.

Intertek

Duluth, Georgia, United States

Intertek's Duluth laboratory is a major multi-discipline EMC, product safety, and wireless testing facility located at 1950 Evergreen Blvd in Duluth, Georgia, in the greater Atlanta metropolitan area. The lab holds A2LA accreditation to ISO/IEC 17025:2017 (Certificate 1455.01, valid through March 2028) and is recognized for FCC testing under the equipment authorization program. The facility's EMC emissions capabilities are exceptionally broad, covering radiated and conducted emissions to FCC Part 15B and Part 18, ICES-001/003, CISPR 11, CISPR 14-1, CISPR 32, EN 55032, EN 55014-1, VCCI-CISPR 32, and numerous regional equivalents including Korean (KS C 9811/9832), South African (SANS), Israeli (SI 961), Hong Kong (HKTA), Taiwanese (CNS), and Australian/New Zealand standards. Current harmonics and voltage flicker testing to the IEC 61000-3-2 and 61000-3-3 series is also accredited. The immunity testing scope covers the full IEC 61000-4 suite — ESD (4-2), radiated RF immunity (4-3), EFT/burst (4-4), surge (4-5), conducted immunity (4-6), power frequency magnetic field (4-8), voltage dips and interruptions (4-11), and close-proximity radiated fields (4-39). Product-specific and generic EMC standards accreditation spans medical devices (IEC 60601-1-2 Editions 2 through 4+Am1), laboratory equipment (IEC 61326 series), ITE/telecom (CISPR 24, EN 55024), multimedia (CISPR 35, EN 55035), household appliances (CISPR 14-1/14-2, EN 55014), lighting (CISPR 15, EN 55015), alarm systems (EN 50130-4), vehicles (CISPR 12), home building automation (IEC 63044-5), professional A/V (EN 55103), and generic light and heavy industrial standards (IEC 61000-6-1 through 6-4) — along with their Korean, South African, and other regional equivalents. Wireless and RF testing capabilities extend to 40 GHz (excluding SAR), supporting FCC Parts 15C/E/F and licensed radio services under Parts 22, 24, 25, 27, 90, 95, 97, and 101, as well as a comprehensive list of ETSI EN standards for European radio approvals, ISED Canada RSS standards, Korean KS X standards, and Asia-Pacific standards for Hong Kong (HKCA), Thailand (NBTC/NTCB), Singapore (IMDA), and Japan (ARIB). Product safety accreditation at Duluth is equally extensive, covering ITE/telecom (IEC/UL/CSA 62368-1, IEC 60950 series), medical devices (IEC 60601-1 and over 30 particular standards in the 60601-2 and 80601-2 series), laboratory equipment (IEC 61010-1 and nine -2 particular standards), audio/video (IEC 60065), and household appliances (IEC 60335-1 and numerous -2 particular standards). This makes Duluth a true one-stop facility for combined EMC and safety certification under a single roof.

Accreditations

ISO/IEC 17025A2LA

Testing Services

Radiated EmissionsConducted EmissionsRadiated ImmunityConducted Immunity+6 more
Alpharetta, Georgia, United States

US Tech is a NIST NVLAP-accredited EMC and product compliance testing laboratory with over 30 years of experience in the industry. The lab supports a broad range of regulatory compliance disciplines including EMC, product safety, telecom, military, avionics, and environmental testing, for both domestic and international markets. On-site testing infrastructure includes a G-TEM cell, a compact semi-anechoic chamber, a 3-meter semi-anechoic chamber, and both 3-meter and 10-meter Open Area Test Sites (OATS). The facility is also equipped with environmental chambers, EMC immunity test systems, and a sound chamber, enabling a wide variety of emissions, immunity, and environmental tests under one roof.

Accreditations

NVLAP

Testing Services

Radiated EmissionsConducted EmissionsRadiated ImmunityConducted Immunity+1 more

All labs worldwide

If you are a supplier shipping into the port or building product in the suburbs, a local pre-scan plus an accredited report can be faster than sending every board spin to a national chain’s distant chamber.

Major metro areas

Listed facilities in Georgia are concentrated around these cities and suburbs.

  • Alpharetta
  • Duluth
  • Atlanta
  • Marietta
  • Norcross
  • Savannah

Common test types requested in Georgia

Drawn from listed lab capabilities and the work teams in this region typically book.

  • Conducted Emissions
  • Conducted Immunity
  • ESD
  • Radiated Emissions
  • Radiated Immunity
  • EFT/Burst
  • Medical Device EMC
  • Power Frequency Magnetic Field

Atlanta’s commercial and industrial mix

Consumer electronics, building controls, and telecom hardware still dominate weekday chamber schedules. Automotive and EV suppliers add CISPR 25 questions as Georgia’s assembly footprint grows. Aerospace work appears when a program wants a Southeast alternative to Huntsville or Florida. Surge and EFT remain the quiet killers on industrial power supplies designed overseas and boxed in Atlanta.

How to book in Georgia

Confirm 3 m versus 10 m radiated capability if your limit set assumes 10 m. Ask whether the lab can run FCC and CISPR in one setup. For vehicle modules, verify a stripline or ALSE rather than a makeshift bench. If you only need debug, say so—accredited report time is priced differently from engineering hours.

Frequently asked questions

Quick answers about EMC testing in Georgia

Is Atlanta enough for FCC certification testing?
For many unintentional radiators, yes. Check that the lab is listed for the FCC rule part you need and that the report format matches your TCB’s expectations.
Do Georgia labs run automotive EMC?
Some do CISPR 25 and related immunity. Vehicle-level work may still go to a Michigan or dedicated automotive site—ask before you crate a mule.