TUV SUD America - New Brighton, MN
Part of TÜV SÜD
More labs in this area: EMC testing in Minnesota
New Brighton, Minnesota, United States
+1 978-573-2500141 14th Street NW, New Brighton, Minnesota, 55112, United States
About
TUV SUD America's New Brighton site on 14th Street NW, in the northern Twin Cities suburbs of Minnesota, is the group's primary medical device and battery testing hub for the Americas and exceeds 55,000 square feet - a 36,000 square foot test facility extended in 2022 by a 20,000 square foot laboratory wing built for biological, chemical and MRI safety work. For EMC the central asset is a 10-metre chamber placed at ground-floor level behind an oversized doorway, so vehicles and large industrial equipment roll in rather than needing a lift, and it is paired with a full vehicle dynamometer and a Mauro TT5.0-7t turntable of 5 metres diameter rated for 7 tonnes - a combination that puts complete vehicle-level EMC within reach, not only component testing. That automotive line runs to CISPR 25, the ISO 11452 series and UN-ECE Regulation 10, and to the OEM specifications that matter in North America including GM's GMW3097 and GMW3172 and Ford's FMC1278, serving GM, Ford, Stellantis and JLR directly. The site has offered battery and battery charger testing in North America since 2009, covering electrical safety, performance, reliability and environmental durability. Its medical practice is unusually complete: electrical safety and EMC to IEC 60601-1 and 60601-1-2, an A2LA-accredited MRI safety laboratory added in 2022 that tests at both 1.5 T and 3 T for RF-induced heating, magnetically induced force and torque and image artifact and produces the resulting device labelling, biocompatibility across the full ISO 10993 range, sterilization validation by vaporized hydrogen peroxide, ethylene oxide and steam, reusable device cleaning and disinfection validation, sterile packaging and transport simulation, and cybersecurity and risk assessment. Accreditations and recognitions are OSHA NRTL, A2LA to ISO/IEC 17025 for both testing and calibration, IECEE CB Testing Laboratory status, FDA ASCA participation, and FCC-recognised Telecommunication Certification Body designation US1148. Specialisations are vehicle-level and component automotive EMC, MRI safety, medical device EMC with biocompatibility and sterilization under one roof, and battery and charger testing.
Accreditations
| Accreditation |
|---|
| ISO/IEC 17025 |
| A2LA |
| IECEE CB Scheme |
| FCC Listed |
| FCC Certified |
Testing Services
| Test Type | Applicable Standards |
|---|---|
| Radiated Emissions | CISPR 11, CISPR 32, CISPR 25, CISPR 14-1, FCC Part 15B, FCC Part 15C, ANSI C63.4, EN 55011, EN 55032, EN 60601-1-2, UN-ECE R10 |
| Conducted Emissions | CISPR 11, CISPR 32, CISPR 25, CISPR 14-1, FCC Part 15B, FCC Part 68, ANSI C63.4, EN 55011, EN 55032, EN 60601-1-2 |
| Radiated Immunity | IEC 61000-4-3, EN 61000-4-3, EN 55035, IEC 60601-1-2, ISO 11452-2, UN-ECE R10, GMW3097, FMC1278 |
| Conducted Immunity | IEC 61000-4-6, EN 61000-4-6, EN 55035, IEC 60601-1-2, ISO 11452-4, GMW3097, FMC1278 |
| Conducted Susceptibility | ISO 7637-2, ISO 7637-3, ISO 11452-4, IEC 61000-4-6, GMW3097 |
| ESD | IEC 61000-4-2, EN 61000-4-2, IEC 60601-1-2, ISO 10605, GMW3097 |
| EFT/Burst | IEC 61000-4-4, EN 61000-4-4, IEC 60601-1-2 |
| Surge Immunity | IEC 61000-4-5, EN 61000-4-5, IEC 60601-1-2 |
| Harmonics & Flicker | IEC 61000-3-2, EN 61000-3-2, IEC 61000-3-3, EN 61000-3-3 |
| Voltage Dips/Interrupts | IEC 61000-4-11, EN 61000-4-11, IEC 60601-1-2, IEC 61000-4-29 |
| Power Frequency Magnetic Field | IEC 61000-4-8, EN 61000-4-8, IEC 60601-1-2 |
| Bulk Current Injection (BCI) | ISO 11452-4, GMW3097, FMC1278 |
| Pre-Compliance Testing | CISPR 25, CISPR 32, IEC 61000-4-3, IEC 60601-1-2, ANSI C63.4 |
| Radio Equipment Testing | FCC Part 15.247, FCC Part 15.407, FCC Part 68, ETSI EN 301 489-1, ETSI EN 301 489-17, ETSI EN 300 328, ANSI C63.10 |
| Medical Device EMC | IEC 60601-1-2, EN 60601-1-2, IEC 60601-1-11, IEC 61326-2-6 |
| Medical Device Regulatory | IEC 60601-1, ISO 10993-1, ISO 10993-5, ISO 10993-10, ISO 10993-18, ISO 11135, ISO 17665, ISO 11607, ISO 14971, ASTM F2052, ASTM F2182, ASTM F2213, ASTM F2119, Regulation (EU) 2017/745 (MDR) |
| Automotive Component EMC | CISPR 25, ISO 11452-2, ISO 11452-4, ISO 11452-5, ISO 7637-2, ISO 10605, UN-ECE R10 |
| Automotive Vehicle-Level EMC | CISPR 12, ISO 11451-1, ISO 11451-2, ISO 11451-4, UN-ECE R10, SAE J551-1 |
| Automotive OEM Specifications | GMW3097, GMW3172, FMC1278, CISPR 25, ISO 11452 series |
| Environmental Testing | IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-14, IEC 60068-2-30, IEC 60068-2-78, IEC 60529, GMW3172, ISO 16750-4, UN 38.3 |
| Mechanical Testing | IEC 60068-2-6, IEC 60068-2-27, IEC 60068-2-64, ISO 16750-3, GMW3172, ISO 11607 |
| Product Safety | IEC 60601-1, UL 60601-1, IEC 62368-1, UL 62368-1, IEC 61010-1, UL 61010-1, IEC 60335-1, UL 60335-1, IEC 62133-2, UL 2054, UL 1642, IEC 61508, ISO 10218, IEC 61131-2, IEC 60598-1, ISO 3691-4 |
Certifications / Marks
| Certification |
|---|
| FCC |
| CE |
| UKCA |
| IECEE CB Certificate |
| OSHA NRTL mark |
| FDA ASCA |
| UN-ECE E-mark |
| RoHS |
| FCC TCB designation US1148 |
Industries Served
| Industry |
|---|
| Medical Devices |
| Automotive |
| Energy & Power |
| Industrial Equipment |
| Information Technology |
| Consumer Electronics |
| Household Appliances |
| Lighting Products |
| Radio & Wireless |
Major Equipment
| Equipment |
|---|
| 10 m EMC chamber at ground-floor level with oversized equipment doorway |
| Full vehicle dynamometer |
| Mauro TT5.0-7t turntable, 5 m diameter, 7 tonne capacity |
| EMI receiver |
| Spectrum analyser |
| LISN |
| CDN |
| BCI injection probes |
| ESD simulator |
| EFT/burst generator |
| Surge generator |
| Automotive transient generator (ISO 7637) |
| Harmonics and flicker analyser |
| RF power amplifiers and immunity antennas |
| MRI safety laboratory at 1.5 T and 3 T (RF-induced heating, force, torque, image artifact) |
| Biological and chemical testing laboratory (20,000 sq ft, 2022) |
| Biocompatibility laboratory (full ISO 10993 range) |
| Sterilization validation: vaporized hydrogen peroxide, ethylene oxide, steam |
| Reusable device cleaning and disinfection validation facility |
| Sterile packaging and transportation simulation facility |
| Battery and battery charger test facility |
| Environmental and durability chambers |
| Electrical safety laboratory |
| A2LA-accredited calibration laboratory |