TUV SUD America - San Diego, CA
Part of TÜV SÜD
More labs in this area: EMC testing in California
San Diego, California, United States
+1 978-573-250016936 Via Del Campo, San Diego, California, 92127, United States
Additional locations (1)
About
TUV SUD America's San Diego operation is the group's West Coast EMC and product safety base and runs across two sites: the Rancho Bernardo laboratory on Via Del Campo in the north of the city, and a second facility on Mesa Rim Road in the Sorrento Valley technology corridor, which is the address that appears on the company's FCC equipment authorisation filings. The EMC estate comprises both a 3-metre and a 10-metre semi-anechoic chamber, so radiated emissions can be measured at the full 10-metre distance specified by ANSI C63.4 and CISPR rather than inferred from a 3-metre extrapolation - a real distinction for borderline products and for the Class B limits that consumer and IT equipment must meet. Alongside EMC and EMI the laboratory offers radio frequency testing, electrical safety with a dedicated safety lab and wet room, environmental testing, laser product testing to IEC 60825-1, and - unusually for a commercial West Coast site - a defence testing line pointing to MIL-STD-461. It also performs EMC testing at customer sites, which matters for installed systems and equipment too large or too fixed to bring to a chamber. The site operates as an NRTL and CB laboratory, so a single engagement can yield an OSHA NRTL listing for the United States and an IECEE CB certificate for onward national approvals, and TUV SUD America's global market access practice routes results into other jurisdictions from there. Note that the company's United Kingdom approved body recognitions for the Electromagnetic Compatibility Regulations 2016 and the Radio Equipment Regulations 2017, under UK body number 1929, are shown as archived on the UK register as of May 2025, so confirm UKCA routing directly before relying on it. Specialisations are 10-metre chamber emissions measurement, defence and MIL-STD EMC, on-site and field EMC testing, laser product safety, and combined NRTL and CB certification for telecommunications and consumer equipment.
Accreditations
| Accreditation |
|---|
| ISO/IEC 17025 |
| A2LA |
| IECEE CB Scheme |
| FCC Listed |
Testing Services
| Test Type | Applicable Standards |
|---|---|
| Radiated Emissions | CISPR 11, CISPR 32, CISPR 14-1, CISPR 15, FCC Part 15B, FCC Part 15C, ANSI C63.4, EN 55011, EN 55032, MIL-STD-461G RE102 |
| Conducted Emissions | CISPR 11, CISPR 32, CISPR 14-1, CISPR 15, FCC Part 15B, ANSI C63.4, EN 55011, EN 55032, MIL-STD-461G CE101, MIL-STD-461G CE102 |
| Radiated Immunity | IEC 61000-4-3, EN 61000-4-3, EN 55035, EN 61000-6-1, EN 61000-6-2, MIL-STD-461G RS103 |
| Conducted Immunity | IEC 61000-4-6, EN 61000-4-6, EN 55035, EN 61000-6-1, EN 61000-6-2, MIL-STD-461G CS114 |
| Radiated Susceptibility | MIL-STD-461G RS101, MIL-STD-461G RS103, MIL-STD-461G RS105 |
| Conducted Susceptibility | MIL-STD-461G CS101, MIL-STD-461G CS114, MIL-STD-461G CS115, MIL-STD-461G CS116 |
| ESD | IEC 61000-4-2, EN 61000-4-2, ANSI C63.16 |
| EFT/Burst | IEC 61000-4-4, EN 61000-4-4 |
| Surge Immunity | IEC 61000-4-5, EN 61000-4-5 |
| Harmonics & Flicker | IEC 61000-3-2, EN 61000-3-2, IEC 61000-3-3, EN 61000-3-3 |
| Voltage Dips/Interrupts | IEC 61000-4-11, EN 61000-4-11, IEC 61000-4-29 |
| Power Frequency Magnetic Field | IEC 61000-4-8, EN 61000-4-8, MIL-STD-461G RS101 |
| Pre-Compliance Testing | ANSI C63.4, CISPR 32, IEC 61000-4-3, MIL-STD-461G, FCC Part 15B |
| Military EMC | MIL-STD-461F, MIL-STD-461G |
| MIL-STD-461 | MIL-STD-461F, MIL-STD-461G |
| Radio Equipment Testing | FCC Part 15.247, FCC Part 15.407, FCC Part 22, FCC Part 24, ETSI EN 301 489-1, ETSI EN 301 489-17, ETSI EN 300 328, ANSI C63.10 |
| Medical Device EMC | IEC 60601-1-2, EN 60601-1-2 |
| Environmental Testing | IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-14, IEC 60068-2-30, IEC 60068-2-78, IEC 60529 |
| Product Safety | IEC 62368-1, UL 62368-1, IEC 61010-1, UL 61010-1, IEC 60335-1, UL 60335-1, IEC 60598-1, UL 1598, IEC 60825-1, IEC 60601-1, IEC 60947-1, ISO 12100 |
Certifications / Marks
| Certification |
|---|
| FCC |
| CE |
| IECEE CB Certificate |
| OSHA NRTL mark |
| GS mark |
| RoHS |
Industries Served
| Industry |
|---|
| Telecommunications |
| Consumer Electronics |
| Aerospace & Defense |
| Military |
| Medical Devices |
| Automotive |
| Industrial Equipment |
| Household Appliances |
| Information Technology |
| Multimedia |
| Lighting Products |
Major Equipment
| Equipment |
|---|
| 10 m semi-anechoic chamber |
| 3 m semi-anechoic chamber |
| EMI receiver |
| Spectrum analyser |
| LISN |
| CDN |
| ESD simulator |
| EFT/burst generator |
| Surge generator |
| Harmonics and flicker analyser |
| RF power amplifiers and immunity antennas |
| Portable EMC measurement kit for customer-site and field testing |
| Electrical safety laboratory with wet room |
| Laser product test equipment (IEC 60825-1) |
| Environmental test chambers |