About

Compliance Engineering International is, by its own account and by its accreditation record, the only ISO/IEC 17025 accredited electrical test laboratory in Ireland - accredited by INAB under scope 088T - operating from a deliberately rural site at Clonross near Dunshaughlin in County Meath chosen for its very low background electrical noise, with a second office at Randalstown in County Antrim, Northern Ireland. It runs four EMC chambers, and the specification is substantial for a national laboratory: a semi-anechoic chamber measuring 18 by 13 metres fully compliant with CISPR 16 and configured for the 10 metre measurement distance, with a purpose-built turntable taking equipment up to 5 metres long and 5 tonnes - enough for complete vehicles; a fully anechoic room of 9 by 6.7 metres qualified at the 3 metre range for radio testing and emissions above 1 GHz; and a dedicated radiated immunity chamber conforming to EN 61000-4-3. The regulatory designations are what make it a single route to multiple markets: FCC recognition across Part 15 Subparts B, C and F and Part 18, Industry Canada listing for ten RSS standards including RSS-102, RSS-210, RSS-247 and the UWB and millimetre-wave standards, Australian Conformity Assessment Body status, participation in the EU-Korea mutual recognition agreement, registration as an Automotive Technical Service with Ireland's NSAI, accreditation as a Sigfox test house for IoT products, and ILAC MRA membership. Its accredited scope spans EMC, electrical safety, radio and human exposure, with flexible scope available. Specialisations are Irish and UK market access, vehicle-level and large-equipment EMC, radio and IoT certification, medical devices, and multi-jurisdiction certification from one campaign.

Accreditations

Accreditation
ISO/IEC 17025
FCC Listed
ISED (Canada)
KCC (Korea)
APEC MRA
EMC Directive 2014/30/EU
Radio Equipment Directive (RED) 2014/53/EU
UK Radio Equipment Regulations (SI 2017/1206)

Testing Services

Test TypeApplicable Standards
Radiated EmissionsCISPR 16-1-4, CISPR 16-2-3, CISPR 11, EN 55011, CISPR 32, EN 55032, CISPR 14-1, EN 55014-1, CISPR 25, CISPR 12, FCC Part 15B, FCC Part 15C, FCC Part 18, ICES-003, EN 61000-6-3, EN 61000-6-4, UN-ECE R10
Conducted EmissionsCISPR 16-1-2, CISPR 16-2-1, CISPR 11, EN 55011, CISPR 32, EN 55032, CISPR 14-1, EN 55014-1, CISPR 25, FCC Part 15B, FCC Part 18, ICES-003, EN 61000-6-3, EN 61000-6-4
Radiated ImmunityIEC 61000-4-3, EN 61000-4-3, EN 55035, EN 55014-2, EN 61000-6-1, EN 61000-6-2, ISO 11452-2, UN-ECE R10
Conducted ImmunityIEC 61000-4-6, EN 61000-4-6, EN 55035, EN 55014-2, EN 61000-6-1, EN 61000-6-2, ISO 11452-4
Radiated SusceptibilityISO 11452-2, ISO 11452-3, IEC 61000-4-3
Conducted SusceptibilityISO 11452-4, ISO 7637-2, IEC 61000-4-6
ESDIEC 61000-4-2, EN 61000-4-2, ISO 10605
EFT/BurstIEC 61000-4-4, EN 61000-4-4
Surge ImmunityIEC 61000-4-5, EN 61000-4-5
Harmonics & FlickerIEC 61000-3-2, EN 61000-3-2, IEC 61000-3-3, EN 61000-3-3, IEC 61000-3-11, IEC 61000-3-12
Voltage Dips/InterruptsIEC 61000-4-11, EN 61000-4-11, IEC 61000-4-29
Power Frequency Magnetic FieldIEC 61000-4-8, EN 61000-4-8
Bulk Current Injection (BCI)ISO 11452-4
Pre-Compliance TestingCISPR 16, CISPR 32, IEC 61000-4-3, ETSI EN 300 328, FCC Part 15C
Radio Equipment TestingETSI EN 300 328, ETSI EN 300 220, ETSI EN 300 330, ETSI EN 301 893, ETSI EN 302 065, ETSI EN 301 489-1, ETSI EN 301 489-3, ETSI EN 301 489-17, FCC Part 15.247, FCC Part 15.517, RSS-247, RSS-210, RSS-220, RSS-243, RSS-GEN
SAR TestingEN 62479, EN 62311, EN 50566, IEC 62209-2, RSS-102
Medical Device EMCEN 60601-1-2, IEC 60601-1-2
Automotive Component EMCCISPR 25, ISO 11452-2, ISO 11452-4, ISO 7637-2, ISO 10605, UN-ECE R10
Automotive Vehicle-Level EMCUN-ECE R10, CISPR 12, ISO 11451-2
Automotive OEM SpecificationsUN-ECE R10, CISPR 25, ISO 11452 series
Product SafetyEN 62368-1, EN 61010-1, EN 60335-1, EN 60601-1

Certifications / Marks

Certification
CE
UKCA
FCC
ISED
RCM
KC
UN-ECE E-mark
Sigfox Verified

Industries Served

Industry
Medical Devices
Automotive
Industrial Equipment
Energy & Power
Radio & Wireless
Telecommunications
Information Technology
Consumer Electronics
Household Appliances
Railway

Major Equipment

Equipment
Semi-anechoic chamber 18 x 13 m, CISPR 16 compliant, 10 m measurement range
Purpose-built turntable for equipment to 5 m long and 5 tonnes
Fully anechoic room 9 x 6.7 m, 3 m range, qualified above 1 GHz
Dedicated radiated immunity chamber to EN 61000-4-3
Fourth EMC test chamber
Rural low-ambient-noise open area test site
EMI receiver
Spectrum analyser
LISN
CDN
BCI injection probes
ESD simulator
EFT/burst generator
Surge generator
Harmonics and flicker analyser
RF power amplifiers and immunity antennas
Radio and OTA measurement systems
SAR measurement system
Electrical safety test benches