CEI - Compliance Engineering International
Dunshaughlin, County Meath, Ireland
+353 1 801 7000Clonross, Dunshaughlin, Dunshaughlin, County Meath, A85 XN59, Ireland
Additional locations (1)
About
Compliance Engineering International is, by its own account and by its accreditation record, the only ISO/IEC 17025 accredited electrical test laboratory in Ireland - accredited by INAB under scope 088T - operating from a deliberately rural site at Clonross near Dunshaughlin in County Meath chosen for its very low background electrical noise, with a second office at Randalstown in County Antrim, Northern Ireland. It runs four EMC chambers, and the specification is substantial for a national laboratory: a semi-anechoic chamber measuring 18 by 13 metres fully compliant with CISPR 16 and configured for the 10 metre measurement distance, with a purpose-built turntable taking equipment up to 5 metres long and 5 tonnes - enough for complete vehicles; a fully anechoic room of 9 by 6.7 metres qualified at the 3 metre range for radio testing and emissions above 1 GHz; and a dedicated radiated immunity chamber conforming to EN 61000-4-3. The regulatory designations are what make it a single route to multiple markets: FCC recognition across Part 15 Subparts B, C and F and Part 18, Industry Canada listing for ten RSS standards including RSS-102, RSS-210, RSS-247 and the UWB and millimetre-wave standards, Australian Conformity Assessment Body status, participation in the EU-Korea mutual recognition agreement, registration as an Automotive Technical Service with Ireland's NSAI, accreditation as a Sigfox test house for IoT products, and ILAC MRA membership. Its accredited scope spans EMC, electrical safety, radio and human exposure, with flexible scope available. Specialisations are Irish and UK market access, vehicle-level and large-equipment EMC, radio and IoT certification, medical devices, and multi-jurisdiction certification from one campaign.
Accreditations
| Accreditation |
|---|
| ISO/IEC 17025 |
| FCC Listed |
| ISED (Canada) |
| KCC (Korea) |
| APEC MRA |
| EMC Directive 2014/30/EU |
| Radio Equipment Directive (RED) 2014/53/EU |
| UK Radio Equipment Regulations (SI 2017/1206) |
Testing Services
| Test Type | Applicable Standards |
|---|---|
| Radiated Emissions | CISPR 16-1-4, CISPR 16-2-3, CISPR 11, EN 55011, CISPR 32, EN 55032, CISPR 14-1, EN 55014-1, CISPR 25, CISPR 12, FCC Part 15B, FCC Part 15C, FCC Part 18, ICES-003, EN 61000-6-3, EN 61000-6-4, UN-ECE R10 |
| Conducted Emissions | CISPR 16-1-2, CISPR 16-2-1, CISPR 11, EN 55011, CISPR 32, EN 55032, CISPR 14-1, EN 55014-1, CISPR 25, FCC Part 15B, FCC Part 18, ICES-003, EN 61000-6-3, EN 61000-6-4 |
| Radiated Immunity | IEC 61000-4-3, EN 61000-4-3, EN 55035, EN 55014-2, EN 61000-6-1, EN 61000-6-2, ISO 11452-2, UN-ECE R10 |
| Conducted Immunity | IEC 61000-4-6, EN 61000-4-6, EN 55035, EN 55014-2, EN 61000-6-1, EN 61000-6-2, ISO 11452-4 |
| Radiated Susceptibility | ISO 11452-2, ISO 11452-3, IEC 61000-4-3 |
| Conducted Susceptibility | ISO 11452-4, ISO 7637-2, IEC 61000-4-6 |
| ESD | IEC 61000-4-2, EN 61000-4-2, ISO 10605 |
| EFT/Burst | IEC 61000-4-4, EN 61000-4-4 |
| Surge Immunity | IEC 61000-4-5, EN 61000-4-5 |
| Harmonics & Flicker | IEC 61000-3-2, EN 61000-3-2, IEC 61000-3-3, EN 61000-3-3, IEC 61000-3-11, IEC 61000-3-12 |
| Voltage Dips/Interrupts | IEC 61000-4-11, EN 61000-4-11, IEC 61000-4-29 |
| Power Frequency Magnetic Field | IEC 61000-4-8, EN 61000-4-8 |
| Bulk Current Injection (BCI) | ISO 11452-4 |
| Pre-Compliance Testing | CISPR 16, CISPR 32, IEC 61000-4-3, ETSI EN 300 328, FCC Part 15C |
| Radio Equipment Testing | ETSI EN 300 328, ETSI EN 300 220, ETSI EN 300 330, ETSI EN 301 893, ETSI EN 302 065, ETSI EN 301 489-1, ETSI EN 301 489-3, ETSI EN 301 489-17, FCC Part 15.247, FCC Part 15.517, RSS-247, RSS-210, RSS-220, RSS-243, RSS-GEN |
| SAR Testing | EN 62479, EN 62311, EN 50566, IEC 62209-2, RSS-102 |
| Medical Device EMC | EN 60601-1-2, IEC 60601-1-2 |
| Automotive Component EMC | CISPR 25, ISO 11452-2, ISO 11452-4, ISO 7637-2, ISO 10605, UN-ECE R10 |
| Automotive Vehicle-Level EMC | UN-ECE R10, CISPR 12, ISO 11451-2 |
| Automotive OEM Specifications | UN-ECE R10, CISPR 25, ISO 11452 series |
| Product Safety | EN 62368-1, EN 61010-1, EN 60335-1, EN 60601-1 |
Certifications / Marks
| Certification |
|---|
| CE |
| UKCA |
| FCC |
| ISED |
| RCM |
| KC |
| UN-ECE E-mark |
| Sigfox Verified |
Industries Served
| Industry |
|---|
| Medical Devices |
| Automotive |
| Industrial Equipment |
| Energy & Power |
| Radio & Wireless |
| Telecommunications |
| Information Technology |
| Consumer Electronics |
| Household Appliances |
| Railway |
Major Equipment
| Equipment |
|---|
| Semi-anechoic chamber 18 x 13 m, CISPR 16 compliant, 10 m measurement range |
| Purpose-built turntable for equipment to 5 m long and 5 tonnes |
| Fully anechoic room 9 x 6.7 m, 3 m range, qualified above 1 GHz |
| Dedicated radiated immunity chamber to EN 61000-4-3 |
| Fourth EMC test chamber |
| Rural low-ambient-noise open area test site |
| EMI receiver |
| Spectrum analyser |
| LISN |
| CDN |
| BCI injection probes |
| ESD simulator |
| EFT/burst generator |
| Surge generator |
| Harmonics and flicker analyser |
| RF power amplifiers and immunity antennas |
| Radio and OTA measurement systems |
| SAR measurement system |
| Electrical safety test benches |