EMC Latest
← Back to Labs Directory
Element Materials Technology - Rockford

Element Materials Technology - Rockford

Part of Element Materials Technology

More labs in this area: EMC testing in Illinois

Rockford, Illinois, United States

+1 815-315-9250

3761 S. Central Avenue, Rockford, Illinois, 61102, United States

About

Element's Rockford laboratory occupies an 83,000 square foot facility on South Central Avenue in Rockford, Illinois, and holds the highest field-strength capability of any laboratory in this directory: a high-field reverberation chamber generating in excess of 22,000 V/m to MIL-STD-464 levels, an order of magnitude beyond the 200 to 600 V/m that most high-intensity facilities reach. Conventional capability is correspondingly deep - radiated susceptibility to MIL-STD-461 RS103 above 200 V/m across 10 kHz to 40 GHz, reverberation chambers qualified for RTCA DO-160 Category L from 100 MHz to 40 GHz, and a 10 metre EMC measurement chamber covering 26 MHz to 40 GHz. Its indirect lightning effects facility runs DO-160 multiple burst and multiple stroke waveforms to Level 5, the most severe category, which together with the HIRF capability makes the site a one-stop route for civil aircraft electrical and electronic equipment qualification. Accreditation is held from A2LA to ISO/IEC 17025 under certificate 214-28 for electrical testing and 214-54 for mechanical, and Element as a group is a Notified Body for the European EMC Directive, an Approved Body for the UK EMC regulations and a Conformity Assessment Body for the FCC. Beyond electromagnetics the site runs environmental simulation across temperature, humidity and altitude in walk-in and bench chambers, structural dynamics including electrodynamic shakers, sine-on-random and classical vibration and pyrotechnic shock, salt spray corrosion testing, power systems testing to 300 kVA, and four-quadrant drive stands rated 500 and 150 horsepower. Specialisations are aerospace HIRF and indirect lightning qualification, MIL-STD-461 and MIL-STD-464 defence programmes, high-field reverberation testing, and combined EMC with dynamics and environmental qualification.

Accreditations

Accreditation
ISO/IEC 17025
A2LA
FCC Listed
ISED (Canada)
EMC Directive 2014/30/EU

Testing Services

Test TypeApplicable Standards
Radiated EmissionsMIL-STD-461G RE101, MIL-STD-461G RE102, MIL-STD-461G RE103, RTCA DO-160G Section 21, CISPR 11, EN 55011, CISPR 32, EN 55032, CISPR 25, CISPR 12, FCC Part 15B, FCC Part 15C, FCC Part 18, EN 61000-6-3, EN 61000-6-4, EN 50121-3-2
Conducted EmissionsMIL-STD-461G CE101, MIL-STD-461G CE102, MIL-STD-461G CE106, RTCA DO-160G Section 21, CISPR 11, EN 55011, CISPR 32, EN 55032, CISPR 25, FCC Part 15B, FCC Part 18, EN 61000-6-3, EN 61000-6-4
Radiated ImmunityMIL-STD-461G RS103, MIL-STD-464, RTCA DO-160G Section 20, IEC 61000-4-3, EN 61000-4-3, EN 55035, EN 61000-6-1, EN 61000-6-2, ISO 11452-2
Conducted ImmunityMIL-STD-461G CS114, MIL-STD-461G CS115, MIL-STD-461G CS116, RTCA DO-160G Section 20, IEC 61000-4-6, EN 61000-4-6, EN 55035, EN 61000-6-1, EN 61000-6-2
Radiated SusceptibilityMIL-STD-461G RS101, MIL-STD-461G RS103, MIL-STD-461G RS105, MIL-STD-464, RTCA DO-160G Section 20, DEF STAN 59-411
Conducted SusceptibilityMIL-STD-461G CS101, MIL-STD-461G CS103, MIL-STD-461G CS104, MIL-STD-461G CS105, MIL-STD-461G CS114, MIL-STD-461G CS115, MIL-STD-461G CS116, MIL-STD-461G CS117, MIL-STD-461G CS118, ISO 7637-2
ESDIEC 61000-4-2, EN 61000-4-2, MIL-STD-461G CS118, RTCA DO-160G Section 25, ISO 10605
EFT/BurstIEC 61000-4-4, EN 61000-4-4
Surge ImmunityIEC 61000-4-5, EN 61000-4-5, RTCA DO-160G Section 22, MIL-STD-461G CS117, IEC 61000-4-12, IEC 61000-4-18
Harmonics & FlickerIEC 61000-3-2, EN 61000-3-2, IEC 61000-3-3, EN 61000-3-3
Voltage Dips/InterruptsIEC 61000-4-11, EN 61000-4-11, IEC 61000-4-29
Power Frequency Magnetic FieldIEC 61000-4-8, EN 61000-4-8, MIL-STD-461G RE101, MIL-STD-461G RS101, RTCA DO-160G Section 15
Bulk Current Injection (BCI)MIL-STD-461G CS114, RTCA DO-160G Section 20, ISO 11452-4
Pre-Compliance TestingMIL-STD-461G, RTCA DO-160G, CISPR 32, IEC 61000-4-3, MIL-STD-464
Military EMCMIL-STD-461G, MIL-STD-461F, MIL-STD-464, DEF STAN 59-411
MIL-STD-461MIL-STD-461F, MIL-STD-461G
Military Power QualityMIL-STD-704F, MIL-STD-1275, MIL-STD-464
Commercial Aviation EMCRTCA DO-160G Section 15, RTCA DO-160G Section 16, RTCA DO-160G Section 17, RTCA DO-160G Section 18, RTCA DO-160G Section 19, RTCA DO-160G Section 20, RTCA DO-160G Section 21, RTCA DO-160G Section 22, RTCA DO-160G Section 23, RTCA DO-160G Section 25
Automotive Component EMCCISPR 25, ISO 11452-2, ISO 11452-4, ISO 11452-5, ISO 7637-2, ISO 10605
Railway EMCEN 50121-1, EN 50121-3-1, EN 50121-3-2, EN 50121-4, EN 50155
Medical Device EMCEN 60601-1-2, IEC 60601-1-2, IEC 61326-2-6
Radio Equipment TestingETSI EN 301 489-1, ETSI EN 301 489-3, ETSI EN 301 489-17, FCC Part 15.247, RSS-247
Product SafetyIEC 62368-1, EN 62368-1, IEC 61010-1, EN 60601-1
Environmental TestingMIL-STD-810H, RTCA DO-160G Section 4, RTCA DO-160G Section 5, RTCA DO-160G Section 6, RTCA DO-160G Section 10, RTCA DO-160G Section 11, RTCA DO-160G Section 14, IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-30, ASTM B117
Mechanical TestingMIL-STD-810H, RTCA DO-160G Section 7, RTCA DO-160G Section 8, IEC 60068-2-6, IEC 60068-2-27, IEC 60068-2-64

Certifications / Marks

Certification
CE
UKCA
FCC
ISED
MIL-STD qualification
DO-160 qualification

Industries Served

Industry
Aerospace & Defense
Military
Automotive
Telecommunications
Medical Devices
Consumer Electronics
Energy & Power
Industrial Equipment
Railway

Major Equipment

Equipment
High-field reverberation chamber generating over 22,000 V/m (MIL-STD-464 levels)
Reverberation chambers qualified for DO-160 Category L, 100 MHz - 40 GHz
10 m EMC measurement chamber, 26 MHz - 40 GHz
RS103 radiated susceptibility above 200 V/m, 10 kHz - 40 GHz
DO-160 indirect lightning effects system, multiple burst and stroke to Level 5
EMI receiver
Spectrum and signal analysers to 40 GHz
LISN
CDN
BCI injection probes
ESD simulator
EFT/burst generator
Surge and damped oscillatory generators
Harmonics and flicker analyser
Power systems test capability to 300 kVA
Four-quadrant drive stands rated 500 HP and 150 HP
MIL-STD-704 / MIL-STD-1275 power quality simulator
Walk-in and bench environmental chambers (temperature, humidity, altitude)
Electrodynamic shaker systems
Pyrotechnic shock test facility
Salt spray corrosion chambers
On-site instrumentation and spectral analysis
83,000 sq ft facility