GB METECC (UK) Ltd
Littlehampton, West Sussex, United Kingdom
+44 1903 942297Unit 2, Minster Court, Courtwick Lane, Wick, Littlehampton, West Sussex, BN17 7RN, United Kingdom
About
GB METECC is an EMC test, consultancy and training company at Minster Court, Courtwick Lane, Wick, near Littlehampton, West Sussex. Peter and Sharon Metcalfe founded it in 2005 as METECC, an EMC consultancy focused on education, regulatory compliance and practical problem-solving. It became GB METECC (UK) Ltd in 2024 and is part of a group with GB Electronics (UK) Ltd, an electronics design and manufacturing firm founded in 1988, and software house GB Logical. The Littlehampton lab covers radiated emissions from 9 kHz to 18 GHz and radiated immunity up to 6 GHz. It also tests conducted emissions, harmonics, flicker and magnetic-field emissions. Immunity tests cover radiated E-field, magnetic field, common-mode RF, EFT, ESD, surge, and dips and interruptions, plus DC-port dips to IEC 61000-4-29. Standards include CISPR 11/EN 55011, CISPR 32/EN 55032, EN 55035, EN IEC 61000-3-2/-3-3, the EN 61000-6 generic series, EN 61326 and FCC Part 15. Testing can also be done on site at customer premises (OATS), and its shielded room can be hired for production or development testing. The company says its testing is UKAS-aligned and follows ISO/IEC 17025 practice, but it does not claim formal accreditation. Its consultancy covers design-for-EMC reviews (PCB layout, shielding, grounding), compliance strategy and CE/UKCA technical files under the EMC, RED, LVD, Machinery, Medical Device and RoHS/WEEE regimes.
Testing Services
| Test Type | Applicable Standards |
|---|---|
| Radiated Emissions | CISPR 11, EN 55011, CISPR 32, EN 55032, EN IEC 61000-6-3, EN IEC 61000-6-4, FCC Part 15 |
| Conducted Emissions | CISPR 11, EN 55011, CISPR 32, EN 55032, FCC Part 15 |
| Radiated Immunity | EN IEC 61000-4-3 |
| Conducted Immunity | EN IEC 61000-4-6 |
| ESD | EN IEC 61000-4-2 |
| EFT/Burst | EN IEC 61000-4-4 |
| Surge Immunity | EN IEC 61000-4-5 |
| Harmonics & Flicker | EN IEC 61000-3-2, EN IEC 61000-3-3 |
| Voltage Dips/Interrupts | EN IEC 61000-4-11, EN IEC 61000-4-29 |
| Power Frequency Magnetic Field | EN IEC 61000-4-8 |
| Pre-Compliance Testing | EN 55035, EN 61000-6-1, EN 61000-6-2, EN 61326 |
| Product Safety | Low Voltage Directive 2014/35/EU (technical file review) |
Certifications / Marks
| Certification |
|---|
| UKCA |
| CE |
| FCC |
Industries Served
| Industry |
|---|
| Industrial Equipment |
| Information Technology |
| Multimedia |
| Consumer Electronics |
| Energy & Power |
Major Equipment
| Equipment |
|---|
| Radiated emissions system 9 kHz-18 GHz |
| Radiated immunity system to 6 GHz |
| Shielded room (available for hire) |
| On-site / OATS test kit |