
INTEK S.p.A.
More labs in this area: EMC testing in Italy · EMC testing in Lombardy
About
INTEK has operated as an accredited test laboratory since 1994 from Via Mazzini at Rezzato, east of Brescia in Lombardy, and its recognition set is one of the broader ones held by an Italian independent laboratory. It is ACCREDIA accredited under number 00855, holds UL recognition as a Third Party Test Data Program participant under reference DA928, is recognised by ACAE and LOVAG under IK01, is an IECEE CB Testing Laboratory, and holds UNECE recognition for vehicle regulation work. That combination lets it serve the Low Voltage, EMC, ATEX and Radio Equipment Directives and route results into the CB Scheme and North American markets from one engagement. The EMC and radio practice sits alongside an unusually heavy electrical and safety capability for a commercial laboratory, including ATEX explosion protection and short-circuit testing, and a deep environmental and mechanical estate covering salt spray, IP ingress protection, climatic and vibration testing, heat resistance of plastics and Arizona dust ingress. Electromagnetic field measurement is offered within the same area as the EMC and radio work. The company emphasises metrology discipline, measurement uncertainty calculation and impartiality, and provides regulatory support across the full product compliance cycle. Sectors served span domestic products, industrial systems, marine, automotive and railway, with sensor and automation equipment called out specifically. Specialisations are ATEX and explosion-protected equipment, short-circuit and high-current testing, marine and railway equipment, automotive approval under UNECE recognition, and CB Scheme routing.
Accreditations
| Accreditation |
|---|
| ISO/IEC 17025 |
| IECEE CB Scheme |
| EMC Directive 2014/30/EU |
| Radio Equipment Directive (RED) 2014/53/EU |
Testing Services
| Test Type | Applicable Standards |
|---|---|
| Radiated Emissions | CISPR 11, EN 55011, CISPR 14-1, EN 55014-1, CISPR 15, EN 55015, CISPR 32, EN 55032, CISPR 25, EN 60945, EN 50121-3-2, UN-ECE R10, EN 61000-6-3, EN 61000-6-4 |
| Conducted Emissions | CISPR 11, EN 55011, CISPR 14-1, EN 55014-1, CISPR 15, EN 55015, CISPR 32, EN 55032, CISPR 25, EN 60945, EN 61000-6-3, EN 61000-6-4 |
| Radiated Immunity | IEC 61000-4-3, EN 61000-4-3, EN 55035, EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 60945, EN 50121-3-2, ISO 11452-2, UN-ECE R10 |
| Conducted Immunity | IEC 61000-4-6, EN 61000-4-6, EN 55035, EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 60945, ISO 11452-4 |
| Conducted Susceptibility | ISO 7637-2, ISO 11452-4, IEC 61000-4-6 |
| ESD | IEC 61000-4-2, EN 61000-4-2, ISO 10605 |
| EFT/Burst | IEC 61000-4-4, EN 61000-4-4 |
| Surge Immunity | IEC 61000-4-5, EN 61000-4-5, IEC 61000-4-12 |
| Harmonics & Flicker | IEC 61000-3-2, EN 61000-3-2, IEC 61000-3-3, EN 61000-3-3, IEC 61000-3-11, IEC 61000-3-12 |
| Voltage Dips/Interrupts | IEC 61000-4-11, EN 61000-4-11, IEC 61000-4-29, IEC 61000-4-34 |
| Power Frequency Magnetic Field | IEC 61000-4-8, EN 61000-4-8, IEC 61000-4-9 |
| Pre-Compliance Testing | CISPR 11, CISPR 32, IEC 61000-4-3, CISPR 25, UN-ECE R10 |
| Radio Equipment Testing | ETSI EN 301 489-1, ETSI EN 301 489-3, ETSI EN 301 489-17, ETSI EN 300 328, ETSI EN 300 220, ETSI EN 300 330 |
| Automotive Component EMC | UN-ECE R10, CISPR 25, ISO 11452-2, ISO 11452-4, ISO 7637-2, ISO 10605 |
| Automotive OEM Specifications | UN-ECE R10, CISPR 25, ISO 11452 series |
| Railway EMC | EN 50121-3-2, EN 50121-4, EN 50155 |
| Product Safety | EN 60335-1, EN 62368-1, EN 61010-1, EN 60598-1, EN 61439-1, EN 60947-1, IEC 60079-0, IEC 60079-1, IEC 60079-11, IEC 60529 |
| Environmental Testing | IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-11, IEC 60068-2-14, IEC 60068-2-30, IEC 60068-2-68, IEC 60068-2-78, IEC 60529 |
| Mechanical Testing | IEC 60068-2-6, IEC 60068-2-27, IEC 60068-2-31, IEC 60068-2-75 |
Certifications / Marks
| Certification |
|---|
| CE |
| IECEE CB Certificate |
| ATEX |
| UN-ECE E-mark |
| UL Third Party Test Data Program (DA928) |
| ACAE / LOVAG (IK01) |
Industries Served
| Industry |
|---|
| Household Appliances |
| Industrial Equipment |
| Energy & Power |
| Automotive |
| Railway |
| Consumer Electronics |
| Lighting Products |
| Information Technology |
| Radio & Wireless |
Major Equipment
| Equipment |
|---|
| EMC test chamber |
| Shielded enclosures |
| EMI receiver |
| Spectrum analyser |
| LISN |
| CDN |
| ESD simulator |
| EFT/burst generator |
| Surge and ring wave generators |
| Automotive transient generator (ISO 7637) |
| Harmonics and flicker analyser |
| RF immunity amplifiers and antennas |
| Electromagnetic field measurement probes |
| Short-circuit and high-current test facility |
| ATEX explosion protection test facilities |
| Salt spray and corrosion chambers |
| IP ingress protection test rigs |
| Arizona dust ingress test chamber |
| Climatic and vibration test facilities |
| Heat resistance of plastics test equipment |
| Metrology and measurement uncertainty laboratory |





