Kiwa Electrical Compliance (formerly RN Electronics)
Brentwood, Essex, United Kingdom
+44 1277 352219Arnolds Court, Arnolds Farm Lane, Mountnessing, Brentwood, Essex, CM13 1UT, United Kingdom
About
Kiwa Electrical Compliance (KEC), formerly RN Electronics, is an EMC, radio and electrical safety test house at Arnolds Court, Mountnessing, near Brentwood, Essex, with more than 30 years of experience. After Kiwa bought it, RN Electronics became part of Kiwa Ltd, now trading as Kiwa Electrical Compliance. It holds UKAS testing accreditation 2360 to ISO/IEC 17025. It is an FCC- and ISED-recognised lab under the US and Canadian MRAs, a UK Approved Body and Northern Ireland Notified Body for EMC, a CB Scheme member, and a VCA Type Approval Partner for UN ECE R10 e-marking. The site has 13 screened rooms and semi- and fully-anechoic chambers, plus open-area test sites from 3 m to 30 m. The accredited EMC scope covers radiated emissions from 9 kHz to 40 GHz, conducted emissions including signal lines, harmonics, flicker and disturbance power. Immunity covers ESD to 15 kV, radiated immunity from 80 MHz to 6 GHz, EFT to 4 kV, surge to 4.4 kV, conducted RF up to 10 V, magnetic fields to 100 A/m, and dips and variations. Product standards include EN 55035, EN 61326, EN 61000-6, EN 60601-1-2, EN 60945, OIML R 51-1 and the EN 301 489 series. Automotive work covers UN R10 revisions 4 to 6, radiated immunity at 30 V/m, BCI and ISO 7637-2 transients. Radio testing covers ETSI short-range, Wi-Fi 6E/7 RLAN (5925-7125 MHz), PMR, 57-71 GHz multi-gigabit and 40-231 GHz short-range devices, plus FCC (ANSI C63.10/C63.26) and ISED RSS. KEC also offers LVD safety, IP testing, 5G and mmWave testing, and CAI cable testing.
Accreditations
| Accreditation |
|---|
| UKAS |
| ISO/IEC 17025 |
| FCC Listed |
| ISED (Canada) |
| IECEE CB Scheme |
| EMC Directive 2014/30/EU |
Testing Services
| Test Type | Applicable Standards |
|---|---|
| Radiated Emissions | EN 55032, EN 55011, EN 55014-1, FCC Part 15, ICES-003 |
| Conducted Emissions | EN 55032, EN 55011, EN 55014-1, FCC Part 15 |
| Radiated Immunity | EN 61000-4-3 |
| Conducted Immunity | EN 61000-4-6 |
| ESD | EN 61000-4-2 |
| EFT/Burst | EN 61000-4-4 |
| Surge Immunity | EN 61000-4-5 |
| Harmonics & Flicker | EN 61000-3-2, EN 61000-3-3 |
| Voltage Dips/Interrupts | EN 61000-4-11, EN 61000-4-29 |
| Power Frequency Magnetic Field | EN 61000-4-8 |
| Medical Device EMC | EN 60601-1-2 |
| Automotive Component EMC | UN ECE R10 Rev 4/5/6, ISO 11452-4 (BCI), ISO 7637-2 |
| Bulk Current Injection (BCI) | ISO 11452-4 |
| Radio Equipment Testing | EN 300 220, EN 300 328, EN 300 330, EN 300 440, EN 301 357, EN 301 893, EN 303 413, EN 302 567, EN 303 722, EN 305 550, EN 301 489 series, ANSI C63.10, ANSI C63.26, RSS-247, RSS-248 |
| Product Safety | Low Voltage Directive 2014/35/EU, IEC 60529 (IP) |
Certifications / Marks
| Certification |
|---|
| CE |
| UKCA |
| UKNI |
| FCC |
| ISED |
| VCCI |
| E-Mark |
| CB Scheme |
Industries Served
| Industry |
|---|
| Radio & Wireless |
| Telecommunications |
| Information Technology |
| Multimedia |
| Industrial Equipment |
| Household Appliances |
| Medical Devices |
| Automotive |
| Consumer Electronics |
Major Equipment
| Equipment |
|---|
| 13 screened rooms and semi/fully anechoic chambers |
| Open area test sites (3 m to 30 m) |
| Radiated emissions to 40 GHz |
| mmWave test systems (57-71 GHz and 40-231 GHz) |
| Automotive radiated immunity 30 V/m (400 MHz-2 GHz) |
| BCI and ISO 7637 transient systems |