EMC Latest

EMC Testing Labs in New York – Accredited Facilities

New York is not one EMC market. Downstate teams look for an accredited EMC testing laboratory near New York City for commercial, medical, and telecom hardware. Upstate programs in Rochester, Buffalo, and the Capital Region look more industrial and sometimes defense.

3

Listed labs

3

Labs with listed accreditations

8

Metro areas

Accredited EMC labs in New York

3 listed facilities, 3 with accreditations on file.

Bohemia, New York, United States+1 location

Dayton T. Brown, Inc. (DTB) is a US-owned and operated testing, engineering, and technical services company founded in 1950, with primary facilities in Bohemia, New York and Hollywood, Maryland. The company is A2LA-accredited (Cert. No. 0767.02) and NVLAP-accredited (Lab Code 200422-0) for EMI/EMC and RTCA/DO-160 testing, and holds NSA certification under the TEMPEST Test Services Program with in-house Certified TEMPEST Professionals (CTPs). DTB is a Department of Defense preferred provider with deep roots in military, aerospace, and defense testing. EMI/EMC capabilities span the full spectrum of military and aerospace requirements: conducted and radiated emissions, conducted and radiated susceptibility, RTCA/DO-160 (all sections, emissions and susceptibility up to 40 GHz, radiated fields exceeding 200 V/m), MIL-STD-461 (revisions A through G), ESD, EMP testing (RS105 radiated and CS116 conducted), lightning testing (single-stroke, multi-stroke, and multi-burst per RTCA/DO-160 Section 22, MIL-STD-461G CS117, and SAE ARP5412), shipboard electrical testing (MIL-STD-1399, MIL-STD-461D/E/F), and shielding effectiveness (IEEE 299, MIL-STD-285, IEC 61726). The facility includes large semi-anechoic chambers, a reverberation/stirred-mode chamber built in collaboration with the US Navy for large armament system testing, and the largest RS105 EMP simulator in any US non-government facility. A dedicated Positive Train Control (PTC) lab supports railroad system compliance with FRA regulations. Power quality testing covers MIL-STD-704, MIL-STD-1399, RTCA/DO-160, and commercial aviation specifications including high power AC (480 V, 3-phase, 600 A) and DC (300 V, 150 A) capabilities. Industries served include military and defense, aerospace and aviation, space, rail and transit, maritime, automotive, medical, heavy equipment, and electric propulsion. DTB has performed testing for programs involving the Astrobotic Peregrine Lunar Lander and is a trusted partner to organizations such as Lockheed Martin, Boeing, Northrop Grumman, and BAE Systems.

Accreditations

A2LAISO/IEC 17025NVLAP

Testing Services

Radiated EmissionsConducted EmissionsRadiated ImmunityConducted Immunity+5 more

Intertek

Skaneateles Falls, New York, United States

Intertek's Skaneateles Falls laboratory is the company's largest electrical testing facility in North America, located at 4341 State Street in Skaneateles Falls, New York, in the Finger Lakes region of central New York. The lab holds A2LA accreditation to ISO/IEC 17025:2017 (Certificate 1350.04, valid through June 2026) and is recognized for FCC testing of unintentional radiators and ISM equipment up to 40 GHz. A defining strength of this facility is its deep medical device testing expertise. The lab holds product safety accreditation for IEC 60601-1 across Editions 2 and 3 (including amendments), the U.S. national deviation (ANSI/AAMI ES60601-1), and Canadian CSA C22.2 No. 60601-1, along with over a dozen particular standards in the 60601-2 and 80601-2 series covering electrocardiographs, monitoring equipment, blood pressure devices, operating tables, multifunction patient monitors, clinical thermometers, and patient hoists. Software lifecycle (IEC 62304), usability (IEC 62366/60601-1-6), alarm systems (60601-1-8), and home healthcare (60601-1-11) are also in scope. Beyond medical, the lab is accredited for IEC/UL 62368-1 for ITE/audio-visual equipment safety. On the EMC side, emissions testing covers radiated and conducted emissions to FCC Part 15B, ICES-001/003, CISPR 11, CISPR 22, CISPR 32, EN 55011, EN 55032, and regional variants including AS/NZS, Korean (KS C), Israeli (SI 961), and VCCI standards. Medical EMC testing to IEC 60601-1-2 is accredited across Editions 2 through 4+Am1, including the Australian AIM 7351731 standard. Current harmonics and voltage flicker testing to the IEC 61000-3-2 and 3-3 series is also covered. The full IEC 61000-4 immunity suite is accredited — ESD (4-2), radiated RF immunity (4-3), EFT/burst (4-4), surge (4-5), conducted immunity (4-6), power frequency magnetic field (4-8), and voltage dips and interruptions (4-11). Product-specific EMC accreditations cover laboratory equipment (the full IEC 61326 series including parts 2-1 through 2-6), wireless coexistence (ANSI C63.27), and ISM equipment emissions to FCC Part 18. The lab also holds mechanical testing accreditation for IP ingress protection testing to IEC 60529 and vibration and shock testing to IEC 60068-2-64 and IEC 60068-2-27 — capabilities that complement the electrical testing scope for products requiring combined environmental and EMC qualification.

Accreditations

ISO/IEC 17025A2LA

Testing Services

Radiated EmissionsConducted EmissionsRadiated ImmunityConducted Immunity+6 more
Ronkonkoma, New York, United States+2 locations

Retlif Testing Laboratories is an ISO/IEC 17025-accredited EMC testing organization with three facilities across the northeastern US, operating since 1978. The lab holds one of the largest ranges of EMC accreditations of any independent lab in North America, with over 140 accredited test methods covering military, aerospace, commercial aviation, rail, maritime, industrial, and commercial wireless applications. Retlif is accredited by ANAB/NAVAIR and recognized by NAVAIR for all aspects of military EMC testing, with results accepted by major airframe manufacturers, shipyards, and military agencies worldwide. EMC testing capabilities span virtually every domestic and international standard, including MIL-STD-461 (all revisions), MIL-STD-285, MIL-STD-704, MIL-STD-1399, MIL-E-6051, MIL-STD-220, NSA 65-5/6, DO-160, the full IEC 61000 series, FCC Parts 2, 15, 18, 74, 90, and 95, and lightning testing (multiple stroke/burst). Testing is available both in-lab and on-site. Retlif is also a Designated Conformity Assessment Body under the European EMC and R&TTE Directives, with accreditations covering Canadian, Japanese VCCI, Australian ACMA, and EU CE requirements. Specific capabilities include emissions and immunity testing, ESD, shielding effectiveness, EMP, high-level radiated susceptibility, power line simulation, and transient testing.

Accreditations

ISO/IEC 17025VCCI (Japan)ISED (Canada)iNARTE

Testing Services

Radiated EmissionsConducted EmissionsRadiated ImmunityConducted Immunity+4 more

All labs worldwide

Search this page by the metro you can actually drive a prototype to. A Long Island slot does not help a Buffalo cabinet.

Major metro areas

Listed facilities in New York are concentrated around these cities and suburbs.

  • Bohemia
  • Ronkonkoma
  • Skaneateles Falls
  • New York
  • Rochester
  • Buffalo
  • Albany
  • Long Island

Common test types requested in New York

Drawn from listed lab capabilities and the work teams in this region typically book.

  • Conducted Emissions
  • Conducted Immunity
  • ESD
  • Radiated Emissions
  • Radiated Immunity
  • MIL-STD-461
  • Military EMC
  • Railway EMC

Two different New Yorks

NYC-adjacent work is consumer, medical, and finance-adjacent electronics that need FCC, ISED, and CE on a launch calendar. Upstate industrial, imaging, and defense suppliers need cabinets, motor drives, and sometimes MIL-STD. Lighting and building products still fail conducted emissions after a driver change. Ask the lab which of those worlds they lived in last month.

How to choose a New York lab

Pick by method and door size, then by borough or upstate city. Confirm 17025 scope. If you need a 10 m chamber or vehicle EMC, you may still leave the state. For medical, ask 60601 questions even if the lab also does FCC. Budget escort time in downstate traffic the same way you budget chamber hours.

Frequently asked questions

Quick answers about EMC testing in New York

Are there EMC labs in New York City?
Some listings are in the metro rather than Manhattan. Read the address. Many teams use New Jersey or Long Island chambers and keep a city office for meetings.
Should upstate companies use a NYC lab?
Only if the method and slot are better. Rochester and Buffalo-area industrial labs are often a better fixture match for cabinets and drives.