ERC-6
Frankonia Germany EMC Solutions GmbH

Product Specifications
Product Details
| Part Number | ERC-6 |
| Manufacturer | Frankonia Germany EMC Solutions GmbH |
| Description | FFT-Based CISPR 16-1 EMI Receiver from 9 kHz to 6 GHz |
General Parameters
| EMC Standards | CISPR 16-1-1 |
| Input Power Level | 97 to 137 dBuV |
| Resolution | 0.1 to 100 Hz |
| Amplitude Accuracy | ±1 to 2 dB |
| Attenuator Step | 5 dB |
| Connectors | BNC, BNC - Female, N Type, N Type - Female |
| Frequency Stability | 1 to 2 ppm |
| IF Bandwidth | 1 kHz, 3 kHz, 9 kHz, 10 kHz, 30 kHz, 100 kHz, 120 kHz, 300 kHz, 1 MHz |
| Impedance | 50 Ohms |
| Interface | USB 2.0, RS-232 |
| Measure & Detection Method | Peak, Quasi-peak, Average, RMS, CISPR-Average |
| Operating Temperature | 0 to 40 Degree C |
| Preamplifier Gain | 15 to 20 dB |
| Preselector | 9 kHz to 6 GHz |
| Real Time | No |
| Spurious Response | -10 to 15 dBuV |
| Weight | 7 kg |
| Attenuation | 0 to 55 dB |
| Supply Voltage | 100 to 240 VAC |
Technical Documents
Technical Articles
EMC Testing Workflow: From Prototype to Certified ProductUnderstanding RTCA/DO-160 Sections for EMC and Environmental TestingEMC Standards and Frequencies at a GlanceTSE Mark - Turkish Standards Institution CertificationBSMI Mark - Bureau of Standards, Metrology and Inspection (Taiwan)CH Mark - Swiss Conformity MarkVCCI Mark