| Part Number | 9010F |
| Manufacturer | Narda Safety Test Solutions |
| Description | CISPR 16-1-1 Compliant FFT EMI Receiver from 10 Hz to 30 MHz |
General Parameters
| Input Power Level | 97 to 137 dBuV |
| Resolution | 0.1 Hz |
| Amplitude Accuracy | ±0.8 to 1 dB |
| Attenuator Step | 5 dB |
| Connectors | N Type, N Type - Female |
| IF Bandwidth | 1, 3, 10, 30, 100, 300 kHz, 10, 100 Hz |
| Impedance | 50 Ohms |
| Interface | RS-232, USB |
| Measure & Detection Method | Peak, Quasi-Peak, Average, RMS, RMS-Avarage, C-Avarage, APD |
| Operating Temperature | -5 to 45 Degree C |
| Preamplifier Gain | 20 dB |
| Real Time | Yes |
| Spurious Response | -7 to 3 dBuV |
| Weight | 4.3 kg |
| Attenuation | 0 to 35 dB |
| Dynamic Range | 80 to 200 dB |
Technical Documents
Technical Articles
EMC Testing Workflow: From Prototype to Certified ProductUnderstanding RTCA/DO-160 Sections for EMC and Environmental TestingEMC Standards and Frequencies at a GlanceTSE Mark - Turkish Standards Institution CertificationBSMI Mark - Bureau of Standards, Metrology and Inspection (Taiwan)CH Mark - Swiss Conformity MarkVCCI Mark
View More >>