Auraexcel Private Limited (AuraXL)
Pune, Maharashtra, India
+91 91721 53223Unit B201, Second Floor, Tower B, Terminal ONE, Phase 1, Rajiv Gandhi Infotech Park, Hinjawadi, Pune, Maharashtra, 411057, India
About
AuraXL, the trading name of Auraexcel Private Limited, is an automotive-focused EMI/EMC testing and consultancy business operating from Terminal ONE in the Rajiv Gandhi Infotech Park at Hinjawadi, Pune - placing it inside the engineering corridor that serves India's western automotive cluster. The company states its ambition as building a world-class EMI/EMC facility in India meeting the highest global standards, and its published service set is full compliance testing on automotive components: radiated and conducted emissions, radiated and conducted immunity, electrostatic discharge and surge immunity, measured against the CISPR 25 and ISO 11452 families that automotive tier suppliers work to. It pairs that with consultancy and training, which is how a substantial part of its customer base - automotive OEMs and their suppliers - engages it: design review and failure diagnosis as much as certification. Customers describe calibrated equipment and experienced engineers. An ISO 9001:2008 quality system is published but no NABL accreditation was found, so the laboratory is recorded here without an accreditation entry. Note that the company's own websites could not be retrieved during research - both auraxl.in and auraxl.com refused automated access - so the capability detail here is drawn from directory listings and verified business records rather than from AuraXL's own pages, and the scope may be broader than shown. Specialisations are automotive component EMI/EMC, EMC consultancy and training for automotive OEMs and tier suppliers, and pre-compliance diagnosis.
Testing Services
| Test Type | Applicable Standards |
|---|---|
| Radiated Emissions | CISPR 25, CISPR 12, CISPR 32, EN 55032, IEC 61000-6-3, IEC 61000-6-4, AIS 004 (Part 3) |
| Conducted Emissions | CISPR 25, CISPR 32, EN 55032, IEC 61000-6-3, IEC 61000-6-4 |
| Radiated Immunity | IEC 61000-4-3, EN 61000-4-3, ISO 11452-2, ISO 11452-11, AIS 004 (Part 3) |
| Conducted Immunity | IEC 61000-4-6, EN 61000-4-6, ISO 11452-4 |
| Radiated Susceptibility | ISO 11452-2, ISO 11452-3, ISO 11452-11 |
| Conducted Susceptibility | ISO 11452-4, ISO 7637-2, ISO 7637-3 |
| ESD | ISO 10605, IEC 61000-4-2, EN 61000-4-2 |
| Surge Immunity | IEC 61000-4-5, EN 61000-4-5 |
| Bulk Current Injection (BCI) | ISO 11452-4 |
| Pre-Compliance Testing | CISPR 25, ISO 11452-2, ISO 11452-4, AIS 004 (Part 3) |
| Automotive Component EMC | CISPR 25, ISO 11452-1, ISO 11452-2, ISO 11452-4, ISO 11452-11, ISO 7637-2, ISO 7637-3, ISO 10605, AIS 004 (Part 3) |
| Automotive OEM Specifications | CISPR 25, ISO 11452 series, AIS 004 (Part 3), UN-ECE R10 |
Certifications / Marks
| Certification |
|---|
| CE |
| AIS / CMVR compliance |
Industries Served
| Industry |
|---|
| Automotive |
| Industrial Equipment |
| Consumer Electronics |
Major Equipment
| Equipment |
|---|
| EMI/EMC test chamber |
| Shielded enclosure |
| EMI receiver |
| Spectrum analyser |
| LISN and artificial networks |
| CDN |
| BCI injection probes |
| ESD simulator to ISO 10605 |
| Surge generator |
| Automotive transient generator (ISO 7637) |
| RF immunity amplifiers and antennas |
| Automotive load simulation bench |