cetecom advanced GmbH
Essen, North Rhine-Westphalia, Germany
+49 2054 9519-0Im Teelbruch 116, Essen, North Rhine-Westphalia, 45219, Germany
Additional locations (1)
About
cetecom advanced operates EMC laboratories at Essen-Kettwig and Saarbruecken, both accredited by DAkkS to DIN EN ISO/IEC 17025:2018, with a sister laboratory in the United States carrying A2LA accreditation - so European and North American testing is performed inside the same organisation. Its automotive designations are unusually layered: it is a designated KBA Technical Service operating under the German E1 approval mark for UN-R 10 amendments 05 and 06, an accredited technical service to the Luxembourg authority SNCH under the E13 mark, and a technical service to Ireland's NSAI for eCall and EMC under the relevant EU regulations and UN regulations - meaning a manufacturer can choose which approval authority issues the certificate without changing laboratory. Test programmes run to the Radio Equipment Directive, the EMC Directive, the Machinery Directive and the medical device rules including IEC 60601-1-2 fourth edition, with railway work to EN 50121 and EN 50155 and shielding attenuation measurement to IEEE 299. Market coverage extends to CE, FCC for the United States, ISED for Canada and MIC for Japan. The laboratories are set up for iterative work rather than pass-fail reporting: customers may attend their own tests, an on-site workshop allows device modifications - filters, shielding materials and specialised connectors - to be fitted and retested within the same session, and the company supports development-phase measurement, modification testing and mass-production quality assurance, with on-site measurement available for plant and machinery. Specialisations are automotive EMC and eCall approval, wireless and multi-radio products, medical technology, railway equipment, and machinery and plant engineering.
Accreditations
| Accreditation |
|---|
| ISO/IEC 17025 |
| DAkkS |
| A2LA |
| FCC Listed |
| ISED (Canada) |
| MIC (Japan) |
| EMC Directive 2014/30/EU |
| Radio Equipment Directive (RED) 2014/53/EU |
Testing Services
| Test Type | Applicable Standards |
|---|---|
| Radiated Emissions | CISPR 32, EN 55032, CISPR 11, EN 55011, CISPR 25, EN 61000-6-3, EN 61000-6-4, EN 50121-3-2, FCC Part 15B, FCC Part 15C, ICES-003, UN-ECE R10 |
| Conducted Emissions | CISPR 32, EN 55032, CISPR 11, EN 55011, CISPR 25, EN 61000-6-3, EN 61000-6-4, FCC Part 15B, ICES-003 |
| Radiated Immunity | IEC 61000-4-3, EN 61000-4-3, EN 55035, EN 61000-6-1, EN 61000-6-2, ISO 11452-2, EN 50121-3-2, UN-ECE R10 |
| Conducted Immunity | IEC 61000-4-6, EN 61000-4-6, EN 55035, EN 61000-6-1, EN 61000-6-2, ISO 11452-4 |
| Radiated Susceptibility | ISO 11452-2, ISO 11452-3, ISO 11452-11, IEC 61000-4-3 |
| Conducted Susceptibility | ISO 11452-4, ISO 7637-2, ISO 7637-3, IEC 61000-4-6 |
| ESD | IEC 61000-4-2, EN 61000-4-2, ISO 10605 |
| EFT/Burst | IEC 61000-4-4, EN 61000-4-4 |
| Surge Immunity | IEC 61000-4-5, EN 61000-4-5 |
| Harmonics & Flicker | IEC 61000-3-2, EN 61000-3-2, IEC 61000-3-3, EN 61000-3-3, IEC 61000-3-11, IEC 61000-3-12 |
| Voltage Dips/Interrupts | IEC 61000-4-11, EN 61000-4-11, IEC 61000-4-29 |
| Power Frequency Magnetic Field | IEC 61000-4-8, EN 61000-4-8 |
| Bulk Current Injection (BCI) | ISO 11452-4 |
| Pre-Compliance Testing | CISPR 25, CISPR 32, IEC 61000-4-3, UN-ECE R10, ETSI EN 301 489-1 |
| Radio Equipment Testing | ETSI EN 301 489-1, ETSI EN 301 489-3, ETSI EN 301 489-17, ETSI EN 301 489-19, ETSI EN 301 489-52, ETSI EN 300 328, ETSI EN 300 220, ETSI EN 301 511, ETSI EN 301 908, FCC Part 15.247, RSS-247 |
| Medical Device EMC | EN 60601-1-2, IEC 60601-1-2 Edition 4, IEC 61326-2-6 |
| Automotive Component EMC | CISPR 25, ISO 11452-1, ISO 11452-2, ISO 11452-4, ISO 11452-5, ISO 11452-11, ISO 7637-2, ISO 7637-3, ISO 10605, UN-ECE R10 |
| Automotive Vehicle-Level EMC | UN-ECE R10 amendment 05, UN-ECE R10 amendment 06, CISPR 12, ISO 11451-2 |
| Automotive OEM Specifications | UN-ECE R10, UN-ECE R144 (eCall), Regulation (EU) 2015/758, CISPR 25, ISO 11452 series |
| Railway EMC | EN 50121-1, EN 50121-2, EN 50121-3-1, EN 50121-3-2, EN 50121-4, EN 50155 |
| Product Safety | EN 62368-1, EN 61010-1, EN 60335-1, EN 60601-1, EN ISO 12100, EN 60204-1 |
Certifications / Marks
| Certification |
|---|
| CE |
| UKCA |
| FCC |
| ISED |
| MIC (Giteki) |
| UN-ECE E1 mark |
| UN-ECE E13 mark |
| eCall type approval |
Industries Served
| Industry |
|---|
| Automotive |
| Medical Devices |
| Railway |
| Industrial Equipment |
| Radio & Wireless |
| Telecommunications |
| Consumer Electronics |
| Information Technology |
Major Equipment
| Equipment |
|---|
| Shielded EMC test chambers |
| Semi-anechoic chambers |
| EMI receiver |
| Spectrum analysers and oscilloscopes |
| RF power amplifiers |
| LISN |
| CDN |
| BCI injection probes |
| ESD simulator |
| EFT/burst generator |
| Surge generator |
| Automotive transient generator (ISO 7637) |
| Harmonics and flicker analyser |
| Shielding attenuation measurement set (IEEE 299) |
| eCall test system |
| Radio and multi-technology test benches |
| On-site workshop with filters, shielding materials and connectors |
| Mobile on-site measurement equipment |