EMC Latest
← Back to Labs Directory
GARC - Global Automotive Research Centre, EMC Facility

GARC - Global Automotive Research Centre, EMC Facility

Kanchipuram, Tamil Nadu, India

+91 44 2714 3500

Plot E1, SIPCOT Industrial Growth Centre, Oragadam, Mathur Post, Sriperumbudur Taluk, Kanchipuram, Tamil Nadu, 602105, India

1 / 4

About

The Global Automotive Research Centre at Oragadam in the SIPCOT Industrial Growth Centre near Chennai is a Government of India automotive test and homologation centre established under the NATRiP programme, and its electromagnetic compatibility facility is the largest vehicle-level EMC installation in this directory. Two absorber-lined semi-anechoic enclosures dominate it: one measuring 30 by 20 by 10 metres with an 11 metre diameter turntable, the other 19.5 by 12 by 8 metres with a 6 metre turntable, both integrated with four-wheel-drive chassis dynamometers so a vehicle can be run under load inside the chamber. Vehicle-level radiated emission measurement covers 30 MHz to 18 GHz off-board and 1.8 MHz to 2 GHz on-board, and radiated immunity runs from 100 kHz to 18 GHz at field strengths up to 200 V/m - across two-wheelers, three-wheelers, passenger cars and light and heavy commercial vehicles, to AIS 004 Part 3, CISPR 12, CISPR 25 and ECE R10. Component-level capability is equally complete: ALSE chambers plus TEM cell, stripline and tri-plate methods, bulk current injection from 1 MHz to 3 GHz with current probes to 300 mA and a tubular wave coupler above 400 MHz, conducted emission by voltage and current probe methods, conducted transient immunity on 12, 24 and 48 volt systems to 100 amperes generating the full ISO 7637 pulse set, ESD to 30 kV air and contact per ISO 10605, and ISO 16750-2 power supply tests. Commercial equipment testing covers harmonics and flicker to 75 amperes, EFT to 4 kV and surge to 6 kV. Altair FEKO simulation supports antenna placement design. Two further component ALSE chambers and an EV charging test environment rated to 720 kW and 1000 A DC are in commissioning. Specialisations are vehicle-level EMC and homologation, electric vehicle and EVSE testing, electronic sub-assembly qualification, and automotive OEM specification programmes.

Accreditations

Accreditation
ISO/IEC 17025
NABL

Testing Services

Test TypeApplicable Standards
Radiated EmissionsAIS 004 (Part 3), CISPR 12, CISPR 25, UN-ECE R10, SAE J1113
Conducted EmissionsCISPR 25, AIS 004 (Part 3), ISO 7637-2
Radiated ImmunityAIS 004 (Part 3), CISPR 25, UN-ECE R10, ISO 11452-2, ISO 11452-3, ISO 11452-5, IEC 61000-4-3
Conducted ImmunityISO 11452-4, IEC 61000-4-6
Radiated SusceptibilityISO 11452-2, ISO 11452-3, ISO 11452-5, ISO 11451-2
Conducted SusceptibilityISO 7637-2, ISO 7637-3, ISO 11452-4, ISO 16750-2
ESDISO 10605, IEC 61000-4-2
EFT/BurstIEC 61000-4-4
Surge ImmunityIEC 61000-4-5
Harmonics & FlickerIEC 61000-3-2, IEC 61000-3-3, IEC 61000-3-11, IEC 61000-3-12
Voltage Dips/InterruptsIEC 61000-4-11, ISO 16750-2
Bulk Current Injection (BCI)ISO 11452-4
Pre-Compliance TestingAIS 004 (Part 3), CISPR 25, UN-ECE R10, ISO 11452-2
Automotive Component EMCCISPR 25, ISO 11452-2, ISO 11452-3, ISO 11452-4, ISO 11452-5, ISO 7637-2, ISO 7637-3, ISO 10605, ISO 16750-2, AIS 004 (Part 3), SAE J1113
Automotive Vehicle-Level EMCAIS 004 (Part 3), CISPR 12, UN-ECE R10, ISO 11451-1, ISO 11451-2, ISO 11451-4
Automotive OEM SpecificationsAIS 004 (Part 3), UN-ECE R10, CISPR 25, SAE J1113, ISO 11452 series

Certifications / Marks

Certification
AIS / CMVR homologation
UN-ECE E-mark
CE
BIS

Industries Served

Industry
Automotive
Industrial Equipment
Energy & Power
Medical Devices
Consumer Electronics
Agricultural & Forestry

Major Equipment

Equipment
ALSE semi-anechoic chamber 30 x 20 x 10 m with 11 m turntable and 4x4 chassis dynamometer
ALSE semi-anechoic chamber 19.5 x 12 x 8 m with 6 m turntable and 4x4 chassis dynamometer
Vehicle radiated immunity to 200 V/m, 100 kHz - 18 GHz
Vehicle radiated emission 30 MHz - 18 GHz off-board, 1.8 MHz - 2 GHz on-board
TEM cell
Stripline
Tri-plate
BCI system 1 MHz - 3 GHz, current probe to 300 mA, tubular wave coupler 400 MHz - 3 GHz
Conducted emission voltage method 150 kHz - 108 MHz
Conducted emission current probe method 150 kHz - 245 MHz
ISO 7637 transient generator for 12 V, 24 V and 48 V systems to 100 A continuous
ESD simulator to 30 kV air and contact (ISO 10605)
ISO 16750-2 power supply test system
Harmonics and flicker bench to 75 A
EFT/burst generator to 4 kV
Surge generator to 6 kV
Altair FEKO electromagnetic simulation for antenna placement
Two component ALSE chambers in commissioning (8.5 x 9.8 x 7 m and 8.6 x 5.3 x 6.1 m)
EV/EVSE charging test environment in commissioning (AC 75 A / 60 kVA, DC 720 kW / 1000 A)