IDEMI - Institute for Design of Electrical Measuring Instruments
Mumbai, Maharashtra, India
+91 22 2405 0301Swatantryaveer Tatya Tope Marg, Eastern Express Highway, Chunabhatti, Sion, Mumbai, Maharashtra, 400022, India
About
IDEMI, the Institute for Design of Electrical Measuring Instruments, is a Government of India society operating as an MSME Technology Centre under the Ministry of Micro, Small and Medium Enterprises, located on Swatantryaveer Tatya Tope Marg beside the Eastern Express Highway at Sion in Mumbai. It is NABL accredited to ISO/IEC 17025:2017 under certificate CC-2287, ISO 9001:2015 certified and - unusually for an MSME institute - holds AS9100 Rev D aerospace accreditation. Its EMC laboratory sits inside a broad technology centre whose remit is to give small manufacturers access to facilities they could not justify alone, and the published EMC scope reflects that practical bent: immunity testing covering electrostatic discharge to 30 kV, electrical fast transient and burst from 0 to 4 kV, surge immunity from 0 to 7 kV, conducted RF susceptibility, magnetic field tests and voltage dips and variations to the IEC and EN 61000 series; and emission testing covering conducted emission from 150 kHz to 30 MHz, harmonic emission to the fortieth harmonic and flicker measurement. Product-specific work runs to the IEC and EN 61000-6 generic standards, IEC 61326-1 for measurement and control equipment, IEC 60601-1-2 for medical devices and the CISPR families. Around the EMC laboratory sit tool room services including precision machining, prototyping and 3D printing, a wide calibration operation spanning electro-technical, thermal, pressure, dimensional and fluid flow disciplines, safety, environmental, LED and pump testing, seismic and bump test facilities, and a substantial training programme. Specialisations are EMC for electrical measuring and control instruments, MSME manufacturer access to shared facilities, aerospace-accredited testing, calibration, and medical device EMC.
Accreditations
| Accreditation |
|---|
| ISO/IEC 17025 |
| NABL |
Testing Services
| Test Type | Applicable Standards |
|---|---|
| Radiated Emissions | CISPR 11, CISPR 14-1, CISPR 15, CISPR 32, IEC 61000-6-3, IEC 61000-6-4, IEC 61326-1 |
| Conducted Emissions | CISPR 11, CISPR 14-1, CISPR 32, IEC 61000-6-3, IEC 61000-6-4, IEC 61326-1 |
| Radiated Immunity | IEC 61000-4-3, EN 61000-4-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61326-1 |
| Conducted Immunity | IEC 61000-4-6, EN 61000-4-6, IEC 61000-6-1, IEC 61000-6-2, IEC 61326-1 |
| ESD | IEC 61000-4-2, EN 61000-4-2 |
| EFT/Burst | IEC 61000-4-4, EN 61000-4-4 |
| Surge Immunity | IEC 61000-4-5, EN 61000-4-5 |
| Harmonics & Flicker | IEC 61000-3-2, EN 61000-3-2, IEC 61000-3-3, EN 61000-3-3, IEC 61000-3-11, IEC 61000-3-12 |
| Voltage Dips/Interrupts | IEC 61000-4-11, EN 61000-4-11, IEC 61000-4-29 |
| Power Frequency Magnetic Field | IEC 61000-4-8, EN 61000-4-8, IEC 61000-4-9 |
| Pre-Compliance Testing | IEC 61000-6-1, IEC 61000-6-2, CISPR 11, IEC 61000-4-3 |
| Medical Device EMC | IEC 60601-1-2, IEC 61326-2-6 |
| Product Safety | IEC 61010-1, IEC 60598-1, IEC 60335-1, IEC 62368-1, IS 302 |
| Environmental Testing | IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-14, IEC 60068-2-30, IEC 60068-2-78, IEC 60529 |
| Mechanical Testing | IEC 60068-2-6, IEC 60068-2-27, IEC 60068-2-29, IEC 60068-2-64 |
Certifications / Marks
| Certification |
|---|
| BIS |
| CE |
| NABL accredited calibration certificates |
| AS9100 Rev D |
Industries Served
| Industry |
|---|
| Industrial Equipment |
| Energy & Power |
| Medical Devices |
| Lighting Products |
| Consumer Electronics |
| Aerospace & Defense |
| Information Technology |
| Household Appliances |
Major Equipment
| Equipment |
|---|
| EMC test chamber |
| Shielded enclosure |
| EMI receiver (conducted emission 150 kHz - 30 MHz) |
| Spectrum analyser |
| LISN |
| CDN |
| ESD simulator to 30 kV |
| EFT/burst generator 0 - 4 kV |
| Surge generator 0 - 7 kV |
| Magnetic field immunity coils |
| Harmonics analyser to the 40th harmonic |
| Flicker meter |
| RF conducted susceptibility system |
| Seismic and bump test facilities |
| Environmental and climatic chambers |
| Precision machining, prototyping and 3D printing tool room |
| Multi-discipline calibration laboratory (CC-2287) |