LCIE Bureau Veritas
Part of Bureau Veritas
More labs in this area: EMC testing in France · EMC testing in Île-de-France · EMC testing in Paris
Fontenay-aux-Roses, Ile-de-France, France
+33 1 40 95 60 6033 Avenue du General Leclerc, Fontenay-aux-Roses, Ile-de-France, 92260, France
About
LCIE - the Laboratoire Central des Industries Electriques, founded in 1882 and part of Bureau Veritas since 2001 - is one of the oldest electrical testing institutions in Europe, and its EMC laboratory at the Fontenay-aux-Roses headquarters south-west of Paris is among the most widely recognised in France. Capability spans conducted and radiated emission measurement, radiated and conducted immunity, harmonic current emission and flicker, indirect lightning effects and high intensity field testing, applied across the CISPR, IEC, EN, ETSI, FCC, ISO, MIL-STD, STANAG and French defence GAM EG13 standard families - a range that lets the same laboratory handle a household appliance, a radio module, a rail traction converter and a defence subsystem. What distinguishes LCIE is the breadth of its regulatory designations rather than any single chamber: it is a notified body under the EMC Directive 2014/30/EU and the Radio Equipment Directive, is recognised by IECEE within the OC-EMC certification scheme, is an FCC Listed laboratory for Part 15 and Part 18, and has been designated by the European Commission under the mutual recognition agreements covering the United States, Canada, Japan, Australia and New Zealand - so a single test campaign can be converted into market access across those jurisdictions without retesting. Sitting inside Bureau Veritas also gives the laboratory access to the group's electrical safety, ATEX, environmental and product certification capability. Specialisations are electrical installation material and switchgear, household and lighting products, connected and IoT devices, medical equipment, rail and automotive systems, and defence electronics.
Accreditations
| Accreditation |
|---|
| ISO/IEC 17025 |
| ISO/IEC 17065 |
| FCC Listed |
| IECEE CB Scheme |
| ISED (Canada) |
| MIC (Japan) |
| APEC MRA |
| EMC Directive 2014/30/EU |
| Radio Equipment Directive (RED) 2014/53/EU |
Testing Services
| Test Type | Applicable Standards |
|---|---|
| Radiated Emissions | CISPR 11, EN 55011, CISPR 14-1, EN 55014-1, CISPR 15, EN 55015, CISPR 32, EN 55032, CISPR 25, FCC Part 15B, FCC Part 15C, FCC Part 18, EN 61000-6-3, EN 61000-6-4 |
| Conducted Emissions | CISPR 11, EN 55011, CISPR 14-1, EN 55014-1, CISPR 32, EN 55032, CISPR 25, FCC Part 15B, FCC Part 18, EN 61000-6-3, EN 61000-6-4 |
| Radiated Immunity | IEC 61000-4-3, EN 61000-4-3, EN 55035, EN 55014-2, EN 61000-6-1, EN 61000-6-2, ISO 11452-2, GAM EG13 |
| Conducted Immunity | IEC 61000-4-6, EN 61000-4-6, EN 55035, EN 55014-2, EN 61000-6-1, EN 61000-6-2 |
| Radiated Susceptibility | MIL-STD-461G RS103, GAM EG13, ISO 11452-2, IEC 61000-4-3 |
| Conducted Susceptibility | MIL-STD-461G CS114, MIL-STD-461G CS115, MIL-STD-461G CS116, GAM EG13, ISO 11452-4 |
| ESD | IEC 61000-4-2, EN 61000-4-2, ISO 10605 |
| EFT/Burst | IEC 61000-4-4, EN 61000-4-4 |
| Surge Immunity | IEC 61000-4-5, EN 61000-4-5, IEC 61000-4-18 |
| Harmonics & Flicker | IEC 61000-3-2, EN 61000-3-2, IEC 61000-3-3, EN 61000-3-3, IEC 61000-3-11, IEC 61000-3-12 |
| Voltage Dips/Interrupts | IEC 61000-4-11, EN 61000-4-11, IEC 61000-4-29, IEC 61000-4-34 |
| Power Frequency Magnetic Field | IEC 61000-4-8, EN 61000-4-8, IEC 61000-4-9, IEC 61000-4-10 |
| Bulk Current Injection (BCI) | ISO 11452-4, MIL-STD-461G CS114 |
| Pre-Compliance Testing | CISPR 32, CISPR 11, IEC 61000-4-3, ETSI EN 300 328 |
| Radio Equipment Testing | ETSI EN 301 489-1, ETSI EN 301 489-3, ETSI EN 301 489-17, ETSI EN 301 489-52, ETSI EN 300 328, ETSI EN 300 220, ETSI EN 300 330, ETSI EN 301 893, FCC Part 15.247, RSS-247 |
| Medical Device EMC | EN 60601-1-2, IEC 60601-1-2 |
| Automotive Component EMC | CISPR 25, ISO 11452-2, ISO 11452-4, ISO 7637-2, ISO 10605, UN-ECE R10 |
| Railway EMC | EN 50121-1, EN 50121-2, EN 50121-3-1, EN 50121-3-2, EN 50121-4, EN 50121-5, EN 50155 |
| Military EMC | MIL-STD-461G, GAM EG13, STANAG 4370, AECTP-500 |
| MIL-STD-461 | MIL-STD-461G |
| Commercial Aviation EMC | RTCA DO-160G Section 20, RTCA DO-160G Section 21, RTCA DO-160G Section 22 |
| Product Safety | EN 60335-1, EN 62368-1, EN 61010-1, EN 60598-1, EN 61439-1, EN 60947-1 |
| Environmental Testing | IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-14, IEC 60068-2-30, IEC 60529, AECTP-300 |
Certifications / Marks
| Certification |
|---|
| CE |
| UKCA |
| FCC |
| ISED |
| NF Mark |
| ENEC |
| IECEE CB Certificate |
| UN-ECE E-mark |
| ATEX |
Industries Served
| Industry |
|---|
| Energy & Power |
| Household Appliances |
| Lighting Products |
| Consumer Electronics |
| Medical Devices |
| Automotive |
| Railway |
| Aerospace & Defense |
| Military |
| Industrial Equipment |
| Radio & Wireless |
| Telecommunications |
| Information Technology |
Major Equipment
| Equipment |
|---|
| Semi-anechoic chambers |
| Fully anechoic chamber |
| Shielded rooms |
| EMI receiver |
| Spectrum analyser |
| LISN |
| CDN |
| High intensity field amplifier chain |
| Indirect lightning effects generator |
| BCI injection probes |
| ESD simulator |
| EFT/burst generator |
| Surge generator |
| Harmonics and flicker analyser |
| Magnetic field immunity coils |
| Automotive transient generator (ISO 7637) |
| Radio test and OTA measurement systems |
| Electrical safety and dielectric test benches |
| Climatic and environmental chambers |