MessTechnikNord GmbH
Wedel, Schleswig-Holstein, Germany
+49 4103 18886-0Industriestrasse 29, Wedel, Schleswig-Holstein, 22880, Germany
About
MessTechnikNord (MTN) at Wedel on the western edge of Hamburg traces its laboratory back to 1968, when it was the measurement department of AEG, and has run as an independent, family-managed GmbH since 2000; a second site at Jena was added in 2013. The depth of its accreditation record is unusual: the calibration laboratory has been accredited since 1979, originally under the DKD and now under DAkkS, and the EMC test laboratory since 1993, with ILAC recognition covering both. That combination - an accredited calibration house inside an accredited test house - means measurement traceability is handled in-house rather than shipped out. The Wedel site operates four semi-anechoic absorber chambers plus shielded rooms and environmental simulation facilities, and offers on-site measurement for equipment that cannot be transported. Testing covers conducted and radiated emissions, the full IEC 61000-4 immunity series, harmonics and flicker, automotive component and vehicle EMC, and combined EMC and environmental qualification of complete systems, so a customer can take a device through the whole programme with one provider. MTN is a designated Technical Service (KBA-P00072) for UN-ECE R10 automotive type approval, and employs a staff of more than forty engineers and technicians. Specialisations are automotive and E-mark approval, maritime and industrial electronics, combined EMC and climatic-mechanical qualification, and accredited calibration of EMC measurement instrumentation.
Accreditations
| Accreditation |
|---|
| ISO/IEC 17025 |
| DAkkS |
| EMC Directive 2014/30/EU |
Testing Services
| Test Type | Applicable Standards |
|---|---|
| Radiated Emissions | CISPR 11, EN 55011, CISPR 32, EN 55032, CISPR 25, EN 61000-6-3, EN 61000-6-4, EN 60945, UN-ECE R10 |
| Conducted Emissions | CISPR 11, EN 55011, CISPR 32, EN 55032, CISPR 25, EN 61000-6-3, EN 61000-6-4, EN 60945 |
| Radiated Immunity | IEC 61000-4-3, EN 61000-4-3, EN 55035, EN 61000-6-1, EN 61000-6-2, ISO 11452-2, EN 60945, UN-ECE R10 |
| Conducted Immunity | IEC 61000-4-6, EN 61000-4-6, EN 55035, EN 61000-6-1, EN 61000-6-2, EN 60945 |
| Radiated Susceptibility | ISO 11452-2, ISO 11452-3, IEC 61000-4-3 |
| Conducted Susceptibility | ISO 11452-4, ISO 7637-2, IEC 61000-4-6 |
| ESD | IEC 61000-4-2, EN 61000-4-2, ISO 10605 |
| EFT/Burst | IEC 61000-4-4, EN 61000-4-4 |
| Surge Immunity | IEC 61000-4-5, EN 61000-4-5 |
| Harmonics & Flicker | IEC 61000-3-2, EN 61000-3-2, IEC 61000-3-3, EN 61000-3-3, IEC 61000-3-11, IEC 61000-3-12 |
| Voltage Dips/Interrupts | IEC 61000-4-11, EN 61000-4-11, IEC 61000-4-29 |
| Power Frequency Magnetic Field | IEC 61000-4-8, EN 61000-4-8 |
| Bulk Current Injection (BCI) | ISO 11452-4 |
| Pre-Compliance Testing | CISPR 25, CISPR 32, IEC 61000-4-3, UN-ECE R10 |
| Automotive Component EMC | CISPR 25, ISO 11452-2, ISO 11452-4, ISO 11452-5, ISO 7637-2, ISO 7637-3, ISO 10605, ISO 16750-2 |
| Automotive Vehicle-Level EMC | UN-ECE R10, CISPR 12, ISO 11451-2 |
| Automotive OEM Specifications | UN-ECE R10, CISPR 25, ISO 11452 series |
| Railway EMC | EN 50121-3-2, EN 50121-4, EN 50155 |
| Medical Device EMC | EN 60601-1-2, IEC 60601-1-2 |
| Environmental Testing | IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-14, IEC 60068-2-30, IEC 60068-2-78, IEC 60529 |
| Mechanical Testing | IEC 60068-2-6, IEC 60068-2-27, IEC 60068-2-64 |
Certifications / Marks
| Certification |
|---|
| CE |
| UN-ECE E-mark |
Industries Served
| Industry |
|---|
| Automotive |
| Industrial Equipment |
| Energy & Power |
| Railway |
| Medical Devices |
| Consumer Electronics |
| Information Technology |
| Telecommunications |
Major Equipment
| Equipment |
|---|
| Four semi-anechoic absorber chambers |
| Shielded rooms |
| EMI receiver |
| Spectrum analyser |
| LISN |
| CDN |
| BCI injection probes |
| ESD simulator |
| EFT/burst generator |
| Surge generator |
| Automotive transient generator (ISO 7637) |
| Harmonics and flicker analyser |
| RF power amplifiers and immunity antennas |
| Climatic chambers |
| Vibration and shock rigs |
| Mobile on-site EMC measurement equipment |
| DAkkS-accredited calibration laboratory for EMC instrumentation |