Vojensky technicky ustav, s.p. - EMC Testing Laboratory (VTUPV Vyskov)
Vyskov, South Moravian Region, Czech Republic
+420 910 105 610Vita Nejedleho 691, Dedice, Vyskov, South Moravian Region, 682 01, Czech Republic
Additional locations (1)
About
The EMC testing laboratory of Vojensky technicky ustav, s.p. (VTU / Military Technical Institute), a Czech state enterprise, was established in 1993 and is one of the longest-operating EMC facilities in the Czech Republic. It sits within the VTUPV branch - the Military Technical Institute of Ground Forces - at Vita Nejedleho 691 in Vyskov-Dedice, and forms part of CIA-accredited testing laboratory No. 1103 under CSN EN ISO/IEC 17025. The laboratory performs both accredited and non-accredited emissions (EMI) and immunity (EMS) work for the Czech Armed Forces and for commercial customers, and is organised into an electromagnetic radiation laboratory, an electromagnetic immunity laboratory, an equipment technical testing laboratory covering automotive transient pulses, UNECE lighting regulations, batteries and vehicle electrics, a development workplace for high-power electromagnetic pulse testing, and a climatic laboratory. Its military specialization has produced equipment that is genuinely uncommon in the region: radiated emissions measurement from 20 Hz to 40 GHz, a large semi-anechoic chamber with a 10 m measurement distance able to accept objects as large as buses and tanks, a reverberation chamber for very high field strengths, and NEMP and UWB high-power electromagnetic pulse simulators. RF immunity was extended with 500 W amplifiers for 1-3 GHz and 350 W for 3-6 GHz feeding a DRH370 dual-ridged horn, giving 250-300 V/m from 1 to 3 GHz and 150-200 V/m from 3 to 6 GHz in the ISO 11452-2 configuration, which brings wireless-band requirements in EN 60601-1-2, EN 50121-3-2 and ISO 11452-2 within reach. Beyond standard EMC tests the laboratory measures electromagnetic shielding effectiveness of rooms, cabinets, containers, enclosures, cables and materials, and its climatic chambers cover dry and damp heat, cold, constant and cyclic humidity, rapid temperature change and condensation to automotive and military profiles, plus salt mist. Railway vehicle testing - including whole coaches - and automotive accessory testing are both routine. VTU also operates Notified Body 2452, and the wider Vyskov site adds electrical safety, mechanical, seismic and vehicle testing.
Accreditations
| Accreditation |
|---|
| ISO/IEC 17025 |
Testing Services
| Test Type | Applicable Standards |
|---|---|
| Radiated Emissions | EN 55011, EN 55032, CISPR 25, 20 Hz - 40 GHz capability |
| Conducted Emissions | EN 55011, EN 55032, CISPR 25 |
| Radiated Immunity | EN 61000-4-3, ISO 11452-2, EN 60601-1-2, EN 50121-3-2, 250-300 V/m at 1-3 GHz, 150-200 V/m at 3-6 GHz |
| Conducted Immunity | EN 61000-4-6, ISO 11452-4 |
| Radiated Susceptibility | MIL-STD-461 RS101, MIL-STD-461 RS103, COS 587001 |
| Conducted Susceptibility | MIL-STD-461 CS101, MIL-STD-461 CS114, MIL-STD-461 CS115, MIL-STD-461 CS116, COS 587001 |
| ESD | EN 61000-4-2 |
| EFT/Burst | EN 61000-4-4 |
| Surge Immunity | EN 61000-4-5 |
| Voltage Dips/Interrupts | EN 61000-4-11 |
| Power Frequency Magnetic Field | EN 61000-4-8, EN 61000-4-9 |
| Bulk Current Injection (BCI) | ISO 11452-4, MIL-STD-461 CS114 |
| Military EMC | COS 587001, MIL-STD-461, NEMP simulation, UWB high-power pulse simulation, Shielding effectiveness of rooms, cabinets, containers, cables and materials |
| MIL-STD-461 | MIL-STD-461F, MIL-STD-461G |
| Automotive Component EMC | ISO 7637-2, ISO 11452-2, ISO 11452-4, CISPR 25, UNECE Regulation 10, UNECE Regulation 48 |
| Automotive Vehicle-Level EMC | UNECE Regulation 10, 10 m semi-anechoic chamber for buses and tracked vehicles |
| Railway EMC | EN 50121-3-2, EN 50121-4, EN 50155, Whole-coach testing in the large semi-anechoic chamber |
| Medical Device EMC | EN 60601-1-2 |
| Pre-Compliance Testing | Non-accredited development testing, Diagnostic and pre-scan measurement |
| Environmental Testing | EN 60068-2 series, MIL-STD-810, Dry and damp heat, Cold, Constant and cyclic humidity, Rapid temperature change and condensation, Salt mist |
Certifications / Marks
| Certification |
|---|
| CE |
| Notified Body 2452 |
| UNECE type approval (E8) |
| COS / NATO conformity |
Industries Served
| Industry |
|---|
| Aerospace & Defense |
| Automotive |
| Energy & Power |
| Industrial Equipment |
| Medical Devices |
| Military |
| Radio & Wireless |
| Railway |
Major Equipment
| Equipment |
|---|
| Large semi-anechoic chamber with 10 m measurement distance (buses, coaches, tracked vehicles) |
| Reverberation chamber |
| NEMP high-power electromagnetic pulse simulator |
| UWB high-power pulse simulator |
| Radiated emissions measurement 20 Hz - 40 GHz |
| 500 W RF power amplifier (1-3 GHz) |
| 350 W RF power amplifier (3-6 GHz) |
| DRH370 dual-ridged horn antenna |
| Automotive transient pulse generators (ISO 7637) |
| BCI injection probes |
| ESD simulator |
| EFT/burst generator |
| Surge generator |
| Shielding effectiveness measurement system |
| Programmable climatic chambers with remote control |
| Salt mist chamber |
| Vehicle and battery electrics test benches |