BE Analytic Solutions LLP
Bengaluru, Karnataka, India
+91 99860 74309B110/B131A, Devasandra Industrial Estate, Mahadevapura, Bengaluru, Karnataka, 560048, India
About
BE Analytic Solutions is a NABL-accredited test laboratory in the Devasandra Industrial Estate at Mahadevapura in east Bengaluru, additionally accredited by the DGAQA - the Indian Ministry of Defence's Directorate General of Aeronautical Quality Assurance - for automotive, aerospace and defence work, which is the credential that opens Indian defence programmes to it. Its EMC scope is the deepest military method set of any laboratory in this directory outside the dedicated national facilities: the MIL-STD-461 programme covers CE101 and CE102 conducted emissions, CS101 and CS114 through CS118 conducted susceptibility - including the lightning induced transient and personnel-borne electrostatic discharge methods added in revision G - RE101 and RE102 radiated emissions, and RS101 through RS103 radiated susceptibility. Alongside that it runs the automotive families (CISPR 25, ISO 7637, ISO 10605 and ISO 11452), the commercial and industrial CISPR 11, 15, 25 and 32 and IEC 61000 series, railway EN 50121, and the aerospace RTCA DO-160 sections covering magnetic effects, power input, RF susceptibility and lightning effects. The environmental estate around the chambers is equally broad - altitude, drop, fungus and mould growth, humidity, high and low temperature, salt spray and corrosion, IP ingress, vibration, thermal cycling and thermal shock, run to MIL-STD, JSS 55555 and IEC standards - and the laboratory operates 24 hours a day, seven days a week, which customers cite as the reason they can compress a qualification programme. A reliability engineering and RAMS consultancy practice sits alongside the testing. Specialisations are defence and aerospace qualification, MIL-STD-461 and DO-160 programmes, automotive components, and combined EMC with environmental and reliability qualification.
Accreditations
| Accreditation |
|---|
| ISO/IEC 17025 |
| NABL |
Testing Services
| Test Type | Applicable Standards |
|---|---|
| Radiated Emissions | MIL-STD-461 RE101, MIL-STD-461 RE102, CISPR 11, CISPR 15, CISPR 25, CISPR 32, RTCA DO-160G Section 21, IEC 61000-6-3, IEC 61000-6-4, EN 50121-3-2 |
| Conducted Emissions | MIL-STD-461 CE101, MIL-STD-461 CE102, CISPR 11, CISPR 15, CISPR 25, CISPR 32, RTCA DO-160G Section 21, IEC 61000-6-3, IEC 61000-6-4 |
| Radiated Immunity | MIL-STD-461 RS103, IEC 61000-4-3, RTCA DO-160G Section 20, ISO 11452-2, IEC 61000-6-1, IEC 61000-6-2, EN 50121-3-2 |
| Conducted Immunity | MIL-STD-461 CS114, MIL-STD-461 CS115, MIL-STD-461 CS116, IEC 61000-4-6, RTCA DO-160G Section 20, ISO 11452-4 |
| Radiated Susceptibility | MIL-STD-461 RS101, MIL-STD-461 RS102, MIL-STD-461 RS103, RTCA DO-160G Section 20, ISO 11452-2, ISO 11452-3 |
| Conducted Susceptibility | MIL-STD-461 CS101, MIL-STD-461 CS114, MIL-STD-461 CS115, MIL-STD-461 CS116, MIL-STD-461G CS117, MIL-STD-461G CS118, ISO 7637-2, ISO 7637-3 |
| ESD | IEC 61000-4-2, ISO 10605, MIL-STD-461G CS118, RTCA DO-160G Section 25 |
| EFT/Burst | IEC 61000-4-4, EN 61000-4-4 |
| Surge Immunity | IEC 61000-4-5, EN 61000-4-5, RTCA DO-160G Section 22, MIL-STD-461G CS117 |
| Harmonics & Flicker | IEC 61000-3-2, IEC 61000-3-3 |
| Voltage Dips/Interrupts | IEC 61000-4-11, IEC 61000-4-29 |
| Power Frequency Magnetic Field | IEC 61000-4-8, MIL-STD-461 RE101, MIL-STD-461 RS101, RTCA DO-160G Section 15 |
| Bulk Current Injection (BCI) | MIL-STD-461 CS114, ISO 11452-4, RTCA DO-160G Section 20 |
| Pre-Compliance Testing | MIL-STD-461F, MIL-STD-461G, RTCA DO-160G, CISPR 25, IEC 61000-4-3 |
| Military EMC | MIL-STD-461E, MIL-STD-461F, MIL-STD-461G, JSS 55555 |
| MIL-STD-461 | MIL-STD-461E, MIL-STD-461F, MIL-STD-461G |
| Commercial Aviation EMC | RTCA DO-160G Section 15, RTCA DO-160G Section 16, RTCA DO-160G Section 17, RTCA DO-160G Section 19, RTCA DO-160G Section 20, RTCA DO-160G Section 21, RTCA DO-160G Section 22, RTCA DO-160G Section 25 |
| Automotive Component EMC | CISPR 25, ISO 7637-2, ISO 7637-3, ISO 10605, ISO 11452-2, ISO 11452-4, ISO 11452-5, AIS 004 (Part 3) |
| Railway EMC | EN 50121-1, EN 50121-3-1, EN 50121-3-2, EN 50121-4, EN 50155 |
| Environmental Testing | MIL-STD-810H, JSS 55555, RTCA DO-160G Section 4, RTCA DO-160G Section 5, RTCA DO-160G Section 6, RTCA DO-160G Section 13, RTCA DO-160G Section 14, IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-10, IEC 60068-2-11, IEC 60068-2-14, IEC 60068-2-30, IEC 60068-2-78, IEC 60529 |
| Mechanical Testing | MIL-STD-810H, JSS 55555, RTCA DO-160G Section 7, RTCA DO-160G Section 8, IEC 60068-2-6, IEC 60068-2-27, IEC 60068-2-31, IEC 60068-2-64 |
Certifications / Marks
| Certification |
|---|
| DGAQA approval |
| MIL-STD qualification |
| DO-160 qualification |
| CE |
Industries Served
| Industry |
|---|
| Aerospace & Defense |
| Military |
| Automotive |
| Medical Devices |
| Railway |
| Energy & Power |
| Industrial Equipment |
| Consumer Electronics |
| Nuclear |
Major Equipment
| Equipment |
|---|
| Shielded rooms and anechoic chambers |
| Measurement coverage to 6 GHz and above |
| EMI receiver |
| Spectrum analyser |
| LISN |
| BCI injection probes and current clamps |
| ESD simulator |
| EFT/burst generator |
| Surge and lightning transient generator |
| Automotive transient generator (ISO 7637) |
| RF power amplifiers and immunity antennas |
| Magnetic field loop antennas and coils |
| Altitude and low pressure chamber |
| Climatic and humidity chambers |
| Thermal cycling and thermal shock chambers |
| Fungus and mould growth chamber |
| Salt spray and corrosion chamber |
| Vibration and mechanical shock rigs |
| Drop test rig |
| IP ingress protection test rigs |
| Reliability and RAMS analysis tools |