BK Services AB
More labs in this area: EMC testing in Sweden
Linköping, Östergötland, Sweden
+46 13 21 26 50Fridtunagatan 24, Linköping, Östergötland, 582 13, Sweden
About
BK Services AB was founded on 1 July 2006 by Johan Bergstrand and Gunnar Karlström, and celebrated its 20th anniversary in 2026. Headquartered at Fridtunagatan 24 in Ebbepark, Linköping — just minutes from the E4 motorway — BK Services conducts approximately 300 test assignments per year across its three test chambers: Kumla (9 kHz–6 GHz emissions and immunity including burst, surge, and ESD), Älvsjö (1–26 GHz radiated emissions and RED spurious/output power measurements), and the new Mjärdevi chamber currently being commissioned (5-metre test distance, 9 kHz–6 GHz, 1 000 V / 200 A power filter). The lab serves consumer, IT, industrial, automotive, aerospace, and military electronics customers, offering pre-compliance and full certification testing for CE (EMC Directive, RED, LVD), FCC Part 15b, CISPR 25/ISO 11452-4 (BCI)/ISO 7637/ISO 10605 for vehicle electronics, and a selection of MIL-STD-461G emission and immunity measurements for military products. Partners include BKD, Nemko, Frendus, and Würth Elektronik.
Testing Services
| Test Type | Applicable Standards |
|---|---|
| Radiated Emissions | CISPR 32, EN 55032, EN 55011, FCC Part 15B, EN 55015, 1–26 GHz (chamber Älvsjö) |
| Conducted Emissions | CISPR 32, EN 55032, FCC Part 15B, 9 kHz–30 MHz |
| Radiated Immunity | IEC/EN 61000-4-3, 80 MHz–6 GHz |
| Conducted Immunity | IEC/EN 61000-4-6, 150 kHz–80 MHz |
| ESD | IEC/EN 61000-4-2 |
| EFT/Burst | IEC/EN 61000-4-4 |
| Surge Immunity | IEC/EN 61000-4-5 |
| Harmonics & Flicker | IEC/EN 61000-3-2, IEC/EN 61000-3-3 |
| Automotive Component EMC | CISPR 25 / EN 55025, ISO 11452-4 (BCI), ISO 7637, ISO 10605 |
| Military EMC | MIL-STD-461G (selected emission and immunity methods) |
| Radio Equipment Testing | RED 2014/53/EU — spurious emission 25 MHz–26 GHz, Output power measurements |
| Pre-Compliance Testing | — |
| Environmental Testing | Climatic testing (temperature, humidity) |
Certifications / Marks
| Certification |
|---|
| CE |
Industries Served
| Industry |
|---|
| Aerospace & Defense |
| Automotive |
| Consumer Electronics |
| Industrial Equipment |
| Information Technology |
| Military |
Major Equipment
| Equipment |
|---|
| Chamber Kumla — 9 kHz–1 GHz emissions, 150 kHz–6 GHz immunity, Burst/Surge/ESD |
| Chamber Älvsjö — 1–26 GHz emissions, RED spurious/output power |
| Chamber Mjärdevi (commissioning) — 5 m, 9 kHz–6 GHz, 1 000 V / 200 A filter |
| Electronics lab for in-situ troubleshooting and filter fitting |