CEcert GmbH
Wismar, Mecklenburg-Western Pomerania, Germany
+49 3841 30305-0Alter Holzhafen 19a, Wismar, Mecklenburg-Western Pomerania, 23966, Germany
About
CEcert GmbH is an independent and neutral test laboratory at Alter Holzhafen 19a in Wismar on the German Baltic coast, accredited by DAkkS to DIN EN ISO/IEC 17025 (D-PL-12049-01-00, covered by the ILAC MRA) across three fields: electromagnetic compatibility, safety of electrical equipment and environmental simulation. It is recognised by the IECEE in the CB Scheme as a CB Testing Laboratory, is a member of Underwriters Laboratories' Third Party Test Data Program, and is a KBA-designated Technical Service in categories A and D, authorising it to carry out EMC tests for EC type-approvals, UN ECE licences and national road traffic regulations. The chamber estate is the headline: an anechoic chamber of 18 m x 13 m x 9 m rated at 3 t/m2, a second of 5 m x 4 m x 3.5 m at 5 t/m2, and a third of 5 m x 5 m x 2.5 m, giving both 3 m and 10 m working sections and the ability to test products weighing up to 3 tonnes. Published emission capability covers conducted disturbance from 9 kHz to 30 MHz single- and three-phase at 25 A, radiated disturbance at 3 to 10 m from 150 kHz to 18 GHz, low-frequency electric and magnetic fields from 5 Hz to 30 kHz, disturbance power from 30 to 300 MHz, mains voltage phenomena (harmonics and flicker) single-phase at 16 A, and safety measurement in electromagnetic fields. Immunity is strong on the high-level end: ESD to 25 kV, RF fields above 100 V/m from 150 kHz to 18 GHz, burst to 4 kV, surge to 4 kV at 1.2/50 us, vehicle on-board electrical transient and harmonic disturbances, induced RF currents at U0 = 30 V, power frequency magnetic fields to 160 A/m and pulse magnetic field immunity to 1,400 A/m. The basic standards list runs beyond the usual set to include IEC 61000-4-12 ring wave, -4-16 common mode 0 Hz to 150 kHz, -4-18 damped oscillatory wave, -4-29 DC port dips and -4-30 power quality measurement. Sector coverage spans medical (IEC 60601-1-2), railway (EN 50155), measurement and laboratory equipment (IEC 61326-1), aviation (RTCA DO-160 section 21), marine (IEC 60945) and automotive (CISPR 25, ECE R10 with E-mark approval service).
Accreditations
| Accreditation |
|---|
| ISO/IEC 17025 |
| DAkkS |
| IECEE CB Scheme |
| EMC Directive 2014/30/EU |
Testing Services
| Test Type | Applicable Standards |
|---|---|
| Radiated Emissions | Radiated disturbance 150 kHz - 18 GHz at 3 m and 10 m, Low frequency electric and magnetic field 5 Hz - 30 kHz, Disturbance power 30 MHz - 300 MHz, CISPR 25, EN 55011, EN 55032 |
| Conducted Emissions | Conducted disturbance 9 kHz - 30 MHz, 1-phase and 3-phase, 25 A, CISPR 25, EN 55011 |
| Radiated Immunity | IEC 61000-4-3, RF fields above 100 V/m, 150 kHz - 18 GHz |
| Conducted Immunity | IEC 61000-4-6, Induced RF currents U0 = 30 V, IEC 61000-4-16 common mode 0 Hz - 150 kHz |
| ESD | IEC 61000-4-2, ESD generation up to 25 kV |
| EFT/Burst | IEC 61000-4-4, Fast transients up to 4 kV, IEC 61000-4-18 damped oscillatory wave |
| Surge Immunity | IEC 61000-4-5, High power transients up to 4 kV, 1.2/50 us, IEC 61000-4-12 ring wave |
| Harmonics & Flicker | Mains voltage phenomena (harmonics and flicker), 1-phase, 16 A, IEC 61000-4-30 power quality measurement |
| Voltage Dips/Interrupts | IEC 61000-4-11, IEC 61000-4-29 DC input power port dips and interruptions, Voltage dips, interrupts and fluctuations on AC and DC supplies |
| Power Frequency Magnetic Field | IEC 61000-4-8 up to 160 A/m, Pulse magnetic field immunity up to 1,400 A/m |
| Medical Device EMC | IEC 60601-1-2 |
| Railway EMC | EN 50155 electronic equipment used on rolling stock |
| Automotive Component EMC | CISPR 25, ECE R10, Vehicle on-board electrical transient and harmonic disturbances |
| Automotive Vehicle-Level EMC | ECE R10, E-mark approval service (motor vehicle directive), KBA Technical Service categories A and D |
| Commercial Aviation EMC | RTCA DO-160 section 21 |
| Pre-Compliance Testing | Test plan creation for normative and development tests, Testing of assemblies, devices and systems |
| Environmental Testing | Environmental simulation testing (accredited field KMF), Safety measurement in electromagnetic fields and environmental tests |
| Product Safety | Safety of electrical equipment (accredited field SEB), Low Voltage Directive 2014/35/EU, IECEE CB Scheme safety standards, IEC 61326-1 measurement, control and laboratory equipment, IEC 60945 marine navigation and radiocommunication equipment |
Certifications / Marks
| Certification |
|---|
| CE |
| CB Certificate (IECEE CBTL) |
| E-mark / ECE type approval |
| KBA Technical Service (categories A and D) |
| UL Third Party Test Data Program member |
| ILAC MRA |
Industries Served
| Industry |
|---|
| Aerospace & Defense |
| Automotive |
| Consumer Electronics |
| Energy & Power |
| Household Appliances |
| Industrial Equipment |
| Medical Devices |
| Railway |
Major Equipment
| Equipment |
|---|
| Anechoic chamber 18 m x 13 m x 9 m (3 t/m2) |
| Anechoic chamber 5 m x 4 m x 3.5 m (5 t/m2) |
| Anechoic chamber 5 m x 5 m x 2.5 m |
| 3 m and 10 m working sections; test items up to 3 tonnes |
| EMI receivers 150 kHz - 18 GHz |
| Low frequency field measurement 5 Hz - 30 kHz |
| Absorbing clamp (disturbance power 30 - 300 MHz) |
| ESD simulator up to 25 kV |
| RF field generation above 100 V/m (150 kHz - 18 GHz) |
| Burst generator up to 4 kV |
| Surge generator up to 4 kV (1.2/50 us) |
| Ring wave and damped oscillatory wave generators |
| Magnetic field coils (160 A/m continuous, 1,400 A/m pulsed) |
| Vehicle on-board transient generators |
| Harmonics and flicker analyser (1-phase, 16 A) |
| Power quality measurement system (IEC 61000-4-30) |
| Environmental simulation laboratory |
| Electrical safety laboratory |