
Central Research Technology Co. (中研科技 / CRT)
Taipei, Taipei, Taiwan
+886-2-2587-2719No. 11, Ln. 41, Fushun St., Zhongshan Dist., Taipei, Taipei, 104, Taiwan
About
Central Research Technology Co. (中研科技股份有限公司, CRT) is a Taipei-based independent EMC and RF testing and certification laboratory at No. 11, Ln. 41, Fushun St., Zhongshan District, Taipei. Its EMC infrastructure is unusually granular: a 22 × 17 × 9 m semi-anechoic chamber (TR1) providing a 10 m measurement distance and a 9 × 6 × 6 m 3 m semi-anechoic chamber (TR11) for final emissions, three fully anechoic EMI debug rooms (two at 7 × 3 × 3 m and one at 7 × 4 × 3 m) for pre-compliance and troubleshooting, a 9 × 5 × 5 m 3 m fully anechoic RF radiation room (TR300), a 6 × 5 × 4 m fully anechoic radiated-susceptibility chamber, dedicated magnetic-field and radiated-power measurement stations, and separate shielded rooms for conducted emissions, conducted susceptibility, EMS/harmonics/flicker, ESD, power-frequency magnetic field, three-phase EMS and RF conducted work. Site validation follows CISPR 16-1-4 and ANSI C63.4:2014 (NSA 30 MHz–1 GHz, SVSWR 1–18 GHz). CRT holds TAF accreditation No. 0905 (EMC/RF), BSMI-designated EMC laboratory status, NVLAP lab code 200575-0, FCC designations TW0019 and TW1104, ISED CAB TW0905, VCCI membership No. 1847 and a TÜV-recognised EMC laboratory certificate, and is an approved EMC lab for Dell and HP. Product scope covers multimedia equipment, ITE, medical electrical equipment, measurement/control/laboratory equipment, lighting, household appliances, ISM, UPS and DC power supplies, plus low-power radio and Wi-Fi 6E devices, with thermal shock, temperature/humidity, vibration and drop-test equipment on site.
Accreditations
| Accreditation |
|---|
| ISO/IEC 17025 |
| NVLAP |
| FCC Listed |
| ISED (Canada) |
| BSMI (Taiwan) |
| VCCI (Japan) |
Testing Services
| Test Type | Applicable Standards |
|---|---|
| Radiated Emissions | CISPR 32 / EN 55032, CISPR 22 / EN 55022, CISPR 11 / EN 55011, CISPR 14-1 / EN 55014-1, CISPR 15 / EN 55015, FCC Part 15 Subpart B, FCC Part 18 (MP-5), ANSI C63.4:2014, VCCI-CISPR 32, ICES-003, ICES-005, CNS 15936, CNS 13438, CNS 13803, CNS 14115, 10 m and 3 m semi-anechoic chambers |
| Conducted Emissions | CISPR 32 / EN 55032, CISPR 22 / EN 55022, CISPR 11 / EN 55011, CISPR 14-1 / EN 55014-1, CISPR 15 / EN 55015, FCC Part 15 Subpart B, VCCI-CISPR 32, CNS 15936 |
| Radiated Immunity | IEC/EN 61000-4-3, CISPR 24 / EN 55024, CISPR 35 / EN 55035, IEEE C37.90.2, ENV 50204, CNS 14676-3 |
| Conducted Immunity | IEC/EN 61000-4-6, ENV 50141, CNS 14676-6 |
| ESD | IEC/EN 61000-4-2, CNS 14676-2 |
| EFT/Burst | IEC/EN 61000-4-4, CNS 14676-4 |
| Surge Immunity | IEC/EN 61000-4-5, IEC/EN 61000-4-12 (ring wave), CNS 14676-5 |
| Harmonics & Flicker | IEC/EN 61000-3-2, IEC/EN 61000-3-12, IEC/EN 61000-3-3, IEC/EN 61000-3-11, CNS 14934 series |
| Voltage Dips/Interrupts | IEC/EN 61000-4-11, IEC/EN 61000-4-34 |
| Power Frequency Magnetic Field | IEC/EN 61000-4-8, CNS 14676-8 |
| Medical Device EMC | IEC/EN 60601-1-2, IEC/EN 61326-1, IEC/EN 61326-2-1, IEC/EN 61326-2-2, IEC/EN 61326-2-3 |
| Radio Equipment Testing | ETSI EN 301 489-1/-3/-7/-17/-19/-24/-52, ETSI EN 300 328, ETSI EN 301 893, ETSI EN 300 220 series, ETSI EN 300 330, ETSI EN 300 440, ETSI EN 303 687 (Wi-Fi 6E), FCC Part 15 Subpart C/E, ANSI C63.10, RSS-Gen, RSS-210, RSS-247, RSS-248, NCC LP0002, AS/NZS 4268 |
| Pre-Compliance Testing | Dedicated EMI debug rooms (TR2, TR6, TR9) |
| Environmental Testing | Thermal shock chamber, High-temperature chamber, Constant temperature and humidity chamber |
| Mechanical Testing | Vibration tester, Drop tester, Free-fall impact tester |
| Product Safety | IEC/EN 62368-1, CNS 14336-1, IEC/EN 60335-1/-2, UL 62368-1, CAN/CSA-C22.2 No. 62368-1, AS/NZS 62368.1 |
Certifications / Marks
| Certification |
|---|
| CE |
| FCC |
| ISED |
| VCCI |
| BSMI |
| NCC |
Industries Served
| Industry |
|---|
| Consumer Electronics |
| Energy & Power |
| Household Appliances |
| Industrial Equipment |
| Information Technology |
| Lighting Products |
| Medical Devices |
| Multimedia |
| Radio & Wireless |
| Telecommunications |
Major Equipment
| Equipment |
|---|
| 10 m semi-anechoic chamber TR1 (22×17×9 m) — EMI final test |
| 3 m semi-anechoic chamber TR11 (9×6×6 m) — EMI final test |
| 3× fully anechoic EMI debug rooms (7×3×3 m ×2, 7×4×3 m) |
| 3 m fully anechoic RF radiation room TR300 (9×5×5 m) |
| Fully anechoic radiated susceptibility chamber TR3 (6×5×4 m) |
| Magnetic field measurement and radiated power measurement stations (TR5) |
| Shielded rooms: conducted emissions, CS, EMS/harmonics/flicker, ESD, ESD/PFMF, 3-phase EMS, RF conducted |
| Reliability equipment: thermal shock, high-temperature and temperature/humidity chambers, vibration, drop and free-fall impact testers |





