Complus Systems Pvt. Ltd.
Bengaluru, Karnataka, India
+91 80 4168 3883No. 79, 1st Floor, 3rd Main Road, Rajajinagar Industrial Town, Bengaluru, Karnataka, 560010, India
About
Complus Systems operates a compact but genuinely equipped EMC laboratory on the first floor of a building in the Rajajinagar Industrial Town in west Bengaluru, combining test services with a business supplying EMC test equipment and antenna measurement systems. The laboratory centres on a semi-anechoic chamber covering radiated measurement to 3 GHz, with radiated emission and immunity, conducted emission and the IEC 61000-4 immunity series run to published scope: electrostatic discharge to IEC 61000-4-2, electrical fast transient to 61000-4-4, surge to 61000-4-5, RF conducted immunity to 61000-4-6 and voltage dips and interruptions to 61000-4-11. Its conducted emission capability is specified more precisely than most - three-phase AC up to 32 amperes and DC from 300 volts up to 32 amperes - which matters for inverters, drives and DC-fed industrial equipment that exceed a single-phase LISN's rating. A distinctive secondary capability is calibration of conducted pulse generators for both commercial and automotive waveforms, work normally done only by equipment manufacturers, and the company's RF facilities are used for troubleshooting as well as formal measurement. Customers describe a well maintained IEC compliance laboratory with knowledgeable technical staff. No ISO/IEC 17025 or NABL accreditation is published, so it is recorded here without an accreditation entry and is best understood as a development, pre-compliance and equipment specialist. Specialisations are IEC 61000 immunity testing, three-phase and DC conducted emission measurement, antenna test systems, and conducted pulse generator calibration.
Testing Services
| Test Type | Applicable Standards |
|---|---|
| Radiated Emissions | CISPR 11, CISPR 32, EN 55011, EN 55032, IEC 61000-6-3, IEC 61000-6-4 |
| Conducted Emissions | CISPR 11, CISPR 32, EN 55011, EN 55032, IEC 61000-6-3, IEC 61000-6-4, CISPR 16-2-1 |
| Radiated Immunity | IEC 61000-4-3, EN 61000-4-3, IEC 61000-6-1, IEC 61000-6-2 |
| Conducted Immunity | IEC 61000-4-6, EN 61000-4-6, IEC 61000-6-1, IEC 61000-6-2 |
| ESD | IEC 61000-4-2, EN 61000-4-2 |
| EFT/Burst | IEC 61000-4-4, EN 61000-4-4 |
| Surge Immunity | IEC 61000-4-5, EN 61000-4-5 |
| Voltage Dips/Interrupts | IEC 61000-4-11, EN 61000-4-11 |
| Conducted Susceptibility | ISO 7637-2, IEC 61000-4-6 |
| Pre-Compliance Testing | CISPR 32, IEC 61000-4-3, IEC 61000-6-2 |
Certifications / Marks
| Certification |
|---|
| CE |
Industries Served
| Industry |
|---|
| Industrial Equipment |
| Consumer Electronics |
| Automotive |
| Energy & Power |
| Information Technology |
| Radio & Wireless |
Major Equipment
| Equipment |
|---|
| Semi-anechoic chamber for radiated measurement to 3 GHz |
| EMI receiver |
| Spectrum analyser |
| Three-phase AC LISN to 32 A |
| DC LISN 300 V to 32 A |
| CDN |
| ESD simulator |
| EFT/burst generator |
| Surge generator |
| RF conducted immunity system |
| Voltage dip and interruption simulator |
| RF troubleshooting bench |
| Antenna test systems |
| Conducted pulse generator calibration facility (commercial and automotive) |