EMC-Testcenter AG (emc testcenter.zürich.ag)
Regensdorf, Zurich, Switzerland
+41 44 302 45 00Moosäckerstrasse 77, Regensdorf, Zurich, 8105, Switzerland
About
EMC-Testcenter AG traces its origins directly to Oerlikon Contraves AG (today Rheinmetall Air Defence AG and RUAG Space AG), the Swiss aerospace and defence giant that was a leader in EMC testing for aerospace and military systems. The company operates today as an independent joint-stock company at Moosäckerstrasse 77, 8105 Regensdorf (Zürich), accredited to ISO/IEC 17025 under Swiss Accreditation Service (SAS) number STS 0034, and listed as an IECEE CB Laboratory since April 2018. In January 2025 the lab achieved NCB (National Certification Body) status, meaning CB certificates can now be issued directly from Regensdorf. EMC-Testcenter AG operates two anechoic chambers: a smaller 8.5 × 5 × 5.5 m chamber and a large-format 20 × 12 × 8 m chamber with 4 × 4 m access doors and 10 t/m² floor load-bearing capacity, capable of accommodating complete military and aerospace systems. The automated test sites cover emission from 16 Hz to 44 GHz and susceptibility from 16 Hz to 40 GHz, with E-field capability to 500 V/m and H-field to 1 kA/m. Standards include the full civil sector (IEC/EN, CISPR, ETSI, FCC), military (MIL-STD-461, VG 95373), civil aviation (DO-160), and personnel EMF safety (EN 50385/50383). A calibration laboratory holds separate SCS accreditation (since September 2023). The lab is Switzerland's only CB-accredited laboratory for photobiological safety testing.
Accreditations
| Accreditation |
|---|
| ISO/IEC 17025 |
| IECEE CB Scheme |
Testing Services
| Test Type | Applicable Standards |
|---|---|
| Radiated Emissions | CISPR 11, CISPR 14-1, CISPR 15, CISPR 32, EN 55011, EN 55032, FCC 47 CFR Part 15 (DoC only), 16 Hz–44 GHz automated emission test site, VG 95373, MIL-STD-461 |
| Conducted Emissions | CISPR 11, CISPR 14-1, CISPR 32, EN 55011, EN 55032, MIL-STD-461, VG 95373 |
| Radiated Immunity | IEC/EN 61000-4-3, EN 55024, EN 55035, 16 Hz–40 GHz automated susceptibility site, up to 500 V/m E-field, 1 kA/m H-field |
| Conducted Immunity | IEC/EN 61000-4-6, MIL-STD-461, VG 95373 |
| Radiated Susceptibility | MIL-STD-461, VG 95373, DO-160 |
| Conducted Susceptibility | MIL-STD-461, VG 95373, DO-160 |
| ESD | IEC/EN 61000-4-2, MIL-STD-461 CS118 |
| EFT/Burst | IEC/EN 61000-4-4 |
| Surge Immunity | IEC/EN 61000-4-5 |
| Harmonics & Flicker | IEC/EN 61000-3-2, IEC/EN 61000-3-3 |
| Voltage Dips/Interrupts | IEC/EN 61000-4-11 |
| Power Frequency Magnetic Field | IEC/EN 61000-4-8 |
| Medical Device EMC | IEC/EN 60601-1-2, IEC/EN 61326, CISPR 11 |
| Military EMC | MIL-STD-461, VG 95373 (German defence standard) |
| Commercial Aviation EMC | RTCA DO-160, DO-213 |
| Radio Equipment Testing | ETSI EN 300 220, ETSI EN 300 330, ETSI EN 300 440, RED 2014/53/EU, WiFi, BLE, GSM, RFID, NFC |
| Wireless Coexistence | WiFi, BLE, RFID, NFC |
| Pre-Compliance Testing | — |
| Product Safety | IEC/EN 60601-1 (Medical), IEC/EN 61010 (Laboratory), IEC/EN 62368-1 (IT/AV), Photobiological safety (only CB-accredited lab in Switzerland), EN 50385/50383 (personnel EMF safety) |
Certifications / Marks
| Certification |
|---|
| CE |
| CB |
Industries Served
| Industry |
|---|
| Aerospace & Defense |
| Automotive |
| Consumer Electronics |
| Household Appliances |
| Industrial Equipment |
| Information Technology |
| Medical Devices |
| Military |
| Radio & Wireless |
| Telecommunications |
Major Equipment
| Equipment |
|---|
| Small Anechoic Chamber — 8.5×5×5.5 m |
| Large Anechoic Chamber — 20×12×8 m; 4×4 m access doors; 10 t/m² floor load; EUT up to 75 t |
| 3× Faraday Rooms (5×4×3 m, 5×5×3 m, 5×3×3 m) + subsystem room |
| Automated emission test site 16 Hz–44 GHz |
| Automated susceptibility test site 16 Hz–40 GHz; up to 500 V/m E-field, 1 kA/m H-field |
| Dual independent video monitoring systems |
| Filtered feedthroughs 1 000 V / 400 A, 400 Vac 3-phase 250 A/phase |
| SCS-accredited calibration laboratory (since 2023) |