EMC Latest
← Back to Labs Directory
EMC Testhaus GmbH & Co. KG

EMC Testhaus GmbH & Co. KG

Siegen, North Rhine-Westphalia, Germany

+49 271 38 27 02

Eiserfelder Strasse 316, Siegen, North Rhine-Westphalia, 57080, Germany

About

EMC Testhaus GmbH & Co. KG at Eiserfelder Strasse 316 in Siegen, North Rhine-Westphalia, is a DAkkS-accredited EMC laboratory operating under registration number D-PL-21526-01-00 to DIN EN ISO/IEC 17025:2018. Its accreditation is unusually well segmented, with separate partial certificates for EMC (-01-01 and -01-02), EMC on medical devices (-01-02), EMC for KBA vehicle type approval (-01-03), FCC requirements (-01-04) and Canadian standards (-01-05), plus a regularly updated published list of test procedures within the flexible accreditation scope. The FCC and Canadian partial accreditations are the notable ones - they let the laboratory support FCC Part 15 and Part 18 Supplier's Declaration of Conformity and Canadian market access directly from Germany. Test equipment covers emission to 18 GHz and immunity to 6 GHz, with equipment for single- and three-phase devices to a maximum 32 A. The facility comprises an absorber chamber with ferrite absorbers, a second absorber chamber with pyramidal absorbers, two weather-independent open-area test sites offering 3 m and 10 m measurement distances, and three shielded cabins; all test and measurement equipment is maintained and calibrated on a fixed cycle per the quality manual, with unbroken traceability of results. As a KBA-designated body it runs type approval procedures for electrical and electronic sub-assemblies (EUB) under UN-R10, verifications under Regulation (EU) 2018/858, BCI testing to ISO 11452-4 over 100 kHz to 400 MHz, testing under the German e-scooter road-traffic regulation, and automotive manufacturer requirements. Medical work covers active medical devices and IVD equipment to DIN EN 60601-1-2:2016 and DIN EN 61326-2-6:2013. The laboratory also holds Germanischer Lloyd recognition for marine work, and performs human EMF exposure assessment in both occupational health contexts (BGV B11, Directive 2013/35/EU) and general population contexts (EU Council Recommendation 1999/519/EC and the 26th German Federal Immission Control Ordinance). Services include full type testing across emission and immunity, development-accompanying measurement, interference suppression, spot tests to verify existing results, and on-site measurement at the installation location.

Accreditations

Accreditation
ISO/IEC 17025
DAkkS
FCC Listed
ISED (Canada)
EMC Directive 2014/30/EU
Radio Equipment Directive (RED) 2014/53/EU

Testing Services

Test TypeApplicable Standards
Radiated EmissionsEN 55011, EN 55032, EN 61000-6-3, EN 61000-6-4, Emission test equipment up to 18 GHz, Absorber chamber (ferrite absorbers), Absorber chamber (pyramidal absorbers), Two weather-independent open-area sites (3 m / 10 m)
Conducted EmissionsEN 55011, EN 55032, EN 61000-6-3, EN 61000-6-4, Single- and three-phase equipment up to 32 A
Radiated ImmunityEN 61000-4-3, EN 61000-6-1, EN 61000-6-2, Immunity test equipment up to 6 GHz
Conducted ImmunityEN 61000-4-6, EN 61000-6-1, EN 61000-6-2
ESDEN 61000-4-2
EFT/BurstEN 61000-4-4
Surge ImmunityEN 61000-4-5
Harmonics & FlickerEN 61000-3-2, EN 61000-3-3, Single- and three-phase up to 32 A
Voltage Dips/InterruptsEN 61000-4-11
Power Frequency Magnetic FieldEN 61000-4-8
Bulk Current Injection (BCI)ISO 11452-4, 100 kHz - 400 MHz
Automotive Component EMCUN-R10 type approval of electrical/electronic sub-assemblies (EUB), Regulation (EU) 2018/858 verifications, ISO 11452-4, German e-scooter (Elektrokleinstfahrzeuge) regulation, Automotive manufacturer requirements
Automotive Vehicle-Level EMCUN-R10, KBA-designated body (Kraftfahrtbundesamt Flensburg), E1 type approval procedures
Medical Device EMCDIN EN 60601-1-2:2016, DIN EN 61326-2-6:2013, Active medical devices and IVD equipment, Directive 2007/47/EC, IVD Directive 98/79/EC
Radio Equipment TestingRadio Equipment Directive 2014/53/EU, FCC Part 15 and Part 18 Supplier's Declaration of Conformity (SDoC), Canadian standards (DAkkS partial accreditation -01-05)
Pre-Compliance TestingDevelopment-accompanying measurement, Interference suppression measures (Entstoerungsmassnahmen), Spot tests to verify existing results, On-site measurement at the installation location, Consulting on standards and declaration of conformity
Product SafetyHuman EMF exposure: BGV B11 / Directive 2013/35/EU (occupational), EU Council Recommendation 1999/519/EC (general population), 26th German Federal Immission Control Ordinance (26. BImSchV), Germanischer Lloyd (marine) recognition

Certifications / Marks

Certification
CE
FCC SDoC
UN-R10 / E1 type approval
KBA-designated body (Flensburg)
Germanischer Lloyd
EU Declaration of Conformity

Industries Served

Industry
Automotive
Consumer Electronics
Energy & Power
Household Appliances
Industrial Equipment
Information Technology
Medical Devices
Radio & Wireless

Major Equipment

Equipment
Absorber chamber with ferrite absorbers
Absorber chamber with pyramidal absorbers
Two weather-independent open-area test sites (3 m and 10 m)
Three shielded cabins
Emission test equipment up to 18 GHz
Immunity test equipment up to 6 GHz
Test equipment for single- and three-phase devices (max 32 A)
BCI system 100 kHz - 400 MHz
ESD simulator
EFT/burst generator
Surge generator
Conducted RF immunity system
Harmonics and flicker analysers
Human EMF exposure measurement equipment
Mobile on-site measurement equipment
Calibration programme with unbroken traceability