About

EMCCons DR. RASEK GmbH & Co. KG is an independent test and calibration laboratory in Franconian Switzerland, headquartered at Boelwiese 8 in Ebermannstadt with a second site at Stoernhofer Berg 15 in Unterleinleiter, between Nuremberg, Erlangen, Fuerth and Bamberg. It describes itself as an EMC pioneer since 1977 with more than 45 years of testing experience, and its facility is one of the most unusual in Europe: several hectares of operating area, an open-area test site supporting measurement distances up to 300 m, a dedicated antenna calibration field, an underground laboratory containing numerous anechoic chambers, a trapezoidal absorber hall, more than 15 shielded rooms, GTEM and TEM cells and triplates, several mode-stirrer and reverberation chambers, motor vehicle roller test stands with extraction systems, MV/LV transformer stations of 630 kVA at 50 Hz, DC, 60 Hz and 400 Hz generator systems, mobile test laboratories, and around 3,000 measuring instruments spanning 0 Hz to 325 GHz with sensitivities down to the noise limit, powers up to megawatts and field strengths up to kV/m. Accreditation is held under DAkkS D-PL-12067-01-00 to DIN EN ISO/IEC 17025:2018, with partial scopes for EMC of active medical devices (-01-01), EMC, wireless applications, electrical appliance safety and environmental testing (-01-02), and EMC of systems, components and separate technical units for motor vehicles and trailers (-01-05), plus a separate DAkkS calibration accreditation D-K-12067-01-00 and - notably for a German laboratory - A2LA accreditation certificate 2032.01 for electrical testing and automotive EMC. The test menu goes far beyond standard conformity work: alongside conducted and radiated emissions and immunity and ESD it covers HEMP, HPM, EMP, HERF, HIRF, LEMP and NEMP, direct lightning impact tests up to 200 kA, indirect lightning effects to avionic and military specifications, DO-160/ED-14 Section 23, ED-105/SAE ARP 5416, MIL-STD-461 and MIL-STD-462, and HERO testing. Environmental simulation covers climatic, vibration and shock, corrosion, pressure, fluid susceptibility, IP, icing, gravel bombardment and drop testing. It also builds and sells its own EMC generators, runs EM simulation and R&D, and teaches seminars on MIL-STD-810, DO-160/ED-14, HIRF/HERF and lightning electromagnetic effects. Remote witness testing is offered via live online connection.

Accreditations

Accreditation
ISO/IEC 17025
DAkkS
A2LA
EMC Directive 2014/30/EU
Radio Equipment Directive (RED) 2014/53/EU

Testing Services

Test TypeApplicable Standards
Radiated EmissionsCISPR 11, CISPR 25, CISPR 32, EN 55032, EN 55011, Open area test site up to 300 m measuring distance, Underground laboratory with numerous anechoic chambers, Trapezoidal absorber hall, 3,000 instruments, 0 Hz to 325 GHz
Conducted EmissionsCISPR 11, CISPR 25, CISPR 32, EN 55032, EN 55011
Radiated ImmunityIEC 61000-4-3, ISO 11452-2, IEC 61000-4-20 (GTEM/TEM), Mode-stirrer and reverberation chambers, Field strengths up to kV/m, powers up to MW
Conducted ImmunityIEC 61000-4-6, ISO 11452-4
Radiated SusceptibilityMIL-STD-461 RS103, MIL-STD-461 RS101, MIL-STD-462, HIRF (High Intensity Radiated Fields), HERF (High Electric Radiated Fields), HPM (High Power Microwave), HEMP / NEMP (Nuclear Electromagnetic Pulse), EMP (Electro-Magnetic Pulse)
Conducted SusceptibilityMIL-STD-461 CS114, MIL-STD-461 CS115, MIL-STD-461 CS116, MIL-STD-462, LEMP (Lightning Electromagnetic Pulse)
ESDIEC 61000-4-2, ISO 10605
EFT/BurstIEC 61000-4-4
Surge ImmunityIEC 61000-4-5, Direct lightning impact tests up to 200 kA, Indirect lightning effects (avionic and military specifications), RTCA DO-160 / EUROCAE ED-14 Section 23, EUROCAE ED-105 / SAE ARP 5416
Harmonics & FlickerEN IEC 61000-3-2, EN 61000-3-3, MV/LV transformer stations 630 kVA / 50 Hz
Voltage Dips/InterruptsIEC 61000-4-11, IEC 61000-4-29, DC, 60 Hz and 400 Hz generator systems
Power Frequency Magnetic FieldIEC 61000-4-8, IEC 61000-4-9, IEC 61000-4-10
Bulk Current Injection (BCI)ISO 11452-4, MIL-STD-461 CS114
Military EMCMIL-STD-461, MIL-STD-462, MIL-STD-810, HERO (Hazards of Electromagnetic Radiation to Ordnance) testing, HEMP / NEMP simulation
MIL-STD-461MIL-STD-461, MIL-STD-462
Commercial Aviation EMCRTCA DO-160, EUROCAE ED-14, HIRF testing, Drone EMC testing, Aircraft and spacecraft equipment
Automotive Component EMCUN-R 10, CISPR 25, ISO 11452-x, ISO 7637-x, DAkkS D-PL-12067-01-05 (KBA scope), Vehicles and heavy-duty equipment, civil and military
Automotive Vehicle-Level EMCUN-R 10, Motor vehicle roller test stands with extraction systems, HIRF testing on vehicles
Railway EMCEN 50121-x railway applications
Medical Device EMCIEC 60601-1-2, DAkkS D-PL-12067-01-01 (active medical devices)
Radio Equipment TestingRadio Equipment Directive 2014/53/EU, Wireless application testing (D-PL-12067-01-02), ETSI EN 301 489-x
Pre-Compliance TestingStandard selection support during development, Test plan preparation, On-site EMC testing worldwide, Mobile test laboratories, Remote live online witness testing, EM simulation, Research and development, Seminars: MIL-STD-810, DO-160/ED-14, HIRF/HERF, lightning
Environmental TestingClimatic and temperature testing, Corrosion testing, Pressure testing, Fluid susceptibility testing, IP testing, Icing testing, Gravel bombardment test, Drop test, MIL-STD-810, RTCA DO-160
Mechanical TestingVibration testing, Shock testing, MIL-STD-810, RTCA DO-160
Product SafetyElectrical safety testing, Safety of electrical appliances (D-PL-12067-01-02), Low Voltage Directive 2014/35/EU

Certifications / Marks

Certification
CE
A2LA Cert. No. 2032.01
DAkkS calibration D-K-12067-01-00
E-mark / UN-R 10 type approval
EU Declaration of Conformity

Industries Served

Industry
Aerospace & Defense
Automotive
Consumer Electronics
Energy & Power
Industrial Equipment
Information Technology
Medical Devices
Military
Radio & Wireless
Railway

Major Equipment

Equipment
Open area test site with up to 300 m measuring distance
Antenna calibration field
Underground laboratory with numerous anechoic chambers
Trapezoidal absorber hall
More than 15 shielded rooms
GTEM and TEM cells, triplates
Several mode-stirrer / reverberation chambers
Motor vehicle roller test stands with extraction systems
MV/LV transformer stations 630 kVA / 50 Hz
DC, 60 Hz and 400 Hz generator systems
Approx. 3,000 measuring instruments, 0 Hz - 325 GHz
Field strengths up to kV/m, powers up to MW
Direct lightning test facility up to 200 kA
Indirect lightning / LEMP generators
HEMP, NEMP, HPM and EMP simulators
HIRF and HERF test facilities
Mobile test laboratories
Environmental simulation laboratory (climatic, vibration, shock, corrosion, pressure, IP, icing)
DAkkS-accredited calibration laboratory
In-house EMC generator manufacturing