FH Graubünden EMV-Prüfzentrum (FHGR)
Chur, Graubünden, Switzerland
+41 81 286 24 62Pulvermühlestrasse 57, Chur, Graubünden, 7000, Switzerland
About
The EMV-Prüfzentrum (EMC Test Centre) at FH Graubünden (University of Applied Sciences Graubünden) is an applied research and pre-compliance EMC laboratory at Pulvermühlestrasse 57, 7000 Chur, affiliated with the Institut für Photonics und Robotics (IPR). The lab features an absorber room (anechoic chamber, approx. 55 m³) and has recently been expanded to cover emission measurements up to 6 GHz. Conducted EMC phenomena are measured from 9 kHz to 230 MHz. The lab is led by scientific project managers Vincenzo Di Toro (+41 81 286 24 62) and Patrik Janett (+41 81 286 37 01). The EMV-Prüfzentrum is explicitly not accredited to ISO/IEC 17025 — it operates as a development-accompanying pre-compliance and comparative measurement service. Via comparative measurements with accredited labs, the team ensures that equipment measured at FHGR will meet the requirements of a standards-compliant laboratory. Services include conducted and radiated emission and immunity from 9 kHz to 6 GHz, ESD, surge, burst, power-frequency magnetic field, mains voltage dips and interruptions, and single-phase harmonics and flicker (up to 16 A). The lab is booked by local and regional industry and is characterised by its cost-effective and flexible approach to development-stage EMC testing.
Testing Services
| Test Type | Applicable Standards |
|---|---|
| Radiated Emissions | 9 kHz–6 GHz, EN 55011, EN 55032, CISPR generic and product standards |
| Conducted Emissions | 9 kHz–30 MHz, EN 55011, EN 55032 |
| Radiated Immunity | IEC/EN 61000-4-3, 80 MHz–9 GHz |
| Conducted Immunity | IEC/EN 61000-4-6, 9 kHz–230 MHz |
| ESD | IEC/EN 61000-4-2 |
| EFT/Burst | IEC/EN 61000-4-4, AC, DC, data lines |
| Surge Immunity | IEC/EN 61000-4-5, AC, DC, data lines |
| Harmonics & Flicker | IEC/EN 61000-3-2, IEC/EN 61000-3-3, Single-phase up to 16 A |
| Voltage Dips/Interrupts | IEC/EN 61000-4-11 |
| Power Frequency Magnetic Field | IEC/EN 61000-4-8, 50/60 Hz |
| Pre-Compliance Testing | — |
Certifications / Marks
| Certification |
|---|
| CE |
Industries Served
| Industry |
|---|
| Consumer Electronics |
| Industrial Equipment |
| Information Technology |
| Medical Devices |
Major Equipment
| Equipment |
|---|
| Anechoic absorber room (~55 m³) — emission up to 6 GHz, immunity 80 MHz–9 GHz |
| Conducted EMC measurement network receivers — 9 kHz to 230 MHz |
| Immunity sources: ESD, surge, burst, PFMF, dips generators |