FORCE Technology is a Danish self-owned, non-profit GTS institute (Approved Technological Service provider) headquartered at Park Alle 345 in Broendby, and is one of Scandinavia's largest technological service companies. Its EMC operation runs across three Nordic sites - Hoersholm and Aarhus in Denmark and Vaesteraas in Sweden - and is among the most heavily equipped in northern Europe. The flagship chamber measures 20.1 x 13.0 x 8.8 m with a 3 x 3 m port, a 5 m turntable rated to 10,000 kg distributed load and a floor rated to 10,000 kg/m2, allowing whole vehicles and large industrial installations to be driven in and measured at 1 m, 3 m or 10 m. The estate includes 10 m and 3 m anechoic chambers with hybrid absorbers, both semi-anechoic and full-anechoic configurations, 10 m and 3 m reverberation chambers reaching roughly 1,000 V/m, multiple shielded rooms and climatic chambers. Published capability covers radiated and conducted emissions from 9 kHz to 40 GHz, radiated immunity from 26 MHz to 40 GHz, ESD to plus or minus 30 kV, EFT/burst to plus or minus 4.8 kV, surge to plus or minus 10 kV, conducted immunity 9 kHz to 230 MHz at up to 30 V RMS or 260 mA, and power-frequency magnetic field to 1,000 A/m, with supplies to 400 VAC three-phase at 125 A / 60 kW, 690 V three-phase AC and 1,100 V DC. Accreditation is ISO/IEC 17025 through DANAK (testing registration no. 100), and FORCE is an IECEE CB Scheme national certification body and CB test laboratory as well as a notified body. For vehicles it is an appointed Designated Technical Service for UNECE R10 covering both electronic sub-assemblies and whole vehicles, and is designated by KBA and STA so it can produce documentation for the German e1 and Swedish e5 schemes. It also operates a genuinely mobile, military-grade MIL-STD-461 test facility that deploys instrumentation and specialists to a customer's own site for security-restricted or untransportable platforms, and runs the EMC Club, a members' network giving access to do-it-yourself pre-testing facilities with in-house specialist support at Hoersholm and Aarhus.

Accreditations

Accreditation
ISO/IEC 17025
ISO/IEC 17065
IECEE CB Scheme
EMC Directive 2014/30/EU

Testing Services

Test TypeApplicable Standards
Radiated EmissionsCISPR 11, CISPR 22, CISPR 25, CISPR 32, EN 55032, 9 kHz - 40 GHz, 1 m / 3 m / 10 m measuring distances
Conducted EmissionsCISPR 11, CISPR 22, CISPR 25, CISPR 32, 9 kHz - 40 GHz
Radiated ImmunityEN/IEC 61000-4-3, 26 MHz - 40 GHz, Reverberation chamber to approx. 1000 V/m
Conducted ImmunityEN/IEC 61000-4-6, 9 kHz - 230 MHz, max 30 V RMS or 260 mA
Radiated SusceptibilityMIL-STD-461 RS103, MIL-STD-461 RS101, Reverberation chamber high field strength
Conducted SusceptibilityMIL-STD-461 CS114, MIL-STD-461 CS115, MIL-STD-461 CS116
ESDEN/IEC 61000-4-2, up to +/- 30 kV
EFT/BurstEN/IEC 61000-4-4, up to +/- 4.8 kV
Surge ImmunityEN/IEC 61000-4-5, up to +/- 10 kV
Harmonics & FlickerEN IEC 61000-3-2, EN 61000-3-3
Voltage Dips/InterruptsEN/IEC 61000-4-11, EN/IEC 61000-4-29
Power Frequency Magnetic FieldEN/IEC 61000-4-8, 50/60 Hz up to 1000 A/m, EN/IEC 61000-4-9, EN/IEC 61000-4-10
Military EMCMIL-STD-461, Mobile military-grade on-site EMC test facility, Deployable instrumentation and specialist team
MIL-STD-461MIL-STD-461, On-site deployable testing at operational or production sites
Automotive Component EMCUNECE Regulation 10, CISPR 25, Electronic Sub-Assemblies (ESA) type approval
Automotive Vehicle-Level EMCUNECE Regulation 10 whole vehicle, Designated Technical Service (KBA e1, STA e5), 20.1 x 13.0 x 8.8 m chamber, 10,000 kg turntable
Medical Device EMCEN/IEC 60601-1-2
Radio Equipment TestingETSI EN 301 489-x, Wireless and IoT product testing, RF performance evaluation
Pre-Compliance TestingEMC Club do-it-yourself pre-testing facilities, In-house specialist support at Hoersholm and Aarhus, Interference investigation and diagnostics
Environmental TestingClimatic chambers, EN 60068-2 series, Extreme testing for harsh environments
Mechanical TestingVibration testing, Mechanical and environmental testing, EN 60068-2-6, EN 60068-2-27
Product SafetyLow Voltage Directive 2014/35/EU, Electrical safety testing, IECEE CB Scheme safety standards

Certifications / Marks

Certification
CE
CB Certificate (IECEE NCB and CBTL)
Notified Body
UNECE R10 Designated Technical Service
e1 (Germany, KBA)
e5 (Sweden, STA)
EC VERIFIED (LAN cables)
CPR Notified Body (EN 50575)
ISO 9001

Industries Served

Industry
Aerospace & Defense
Automotive
Consumer Electronics
Energy & Power
Household Appliances
Industrial Equipment
Information Technology
Medical Devices
Military
Multimedia
Radio & Wireless
Telecommunications

Major Equipment

Equipment
20.1 x 13.0 x 8.8 m EMC chamber with 3 x 3 m port
5 m turntable, 10,000 kg distributed load
Floor load capacity 10,000 kg/m2
10 m and 3 m anechoic chambers with hybrid absorbers (to 40 GHz)
Semi-anechoic (SAC) and full-anechoic (FAC) chambers
10 m and 3 m reverberation chambers (approx. 1000 V/m)
Multiple shielded chambers
Mobile military-grade MIL-STD-461 test facility
EMI receivers 9 kHz - 40 GHz
ESD simulator (+/- 30 kV)
EFT/burst generator (+/- 4.8 kV)
Surge generator (+/- 10 kV)
Conducted immunity system 9 kHz - 230 MHz
Magnetic field coil (1000 A/m)
Supplies to 400 VAC 3-phase 125 A / 60 kW, 690 V 3-phase AC, 1100 V DC
Signal interfaces: Ethernet, VGA, DVI, USB, HDMI, CAN, RS232
Climatic chambers