EMC Latest
← Back to Labs Directory
HCT Co., Ltd.

HCT Co., Ltd.

Part of HCT Co., Ltd.

Icheon, Gyeonggi-do, South Korea

+82 31-645-6300

74 Seoicheon-ro 578beon-gil, Majang-myeon, Icheon, Gyeonggi-do, 17383, South Korea

About

HCT is one of South Korea's largest independent testing and certification houses, working from Seoicheon-ro in Majang-myeon, Icheon-si, Gyeonggi-do, under co-chief executives Huh Bong-Jae and Kwon Yong-taek. Its breadth is the point: eleven declared testing areas covering radio frequency, wired, EMC, specific absorption rate and over-the-air performance, electrical safety, medical, battery, environmental reliability, software, nuclear, automotive electronics and defence. Few laboratories anywhere combine automotive, nuclear, battery and defence under one roof. Its automotive client list is named and substantial - Hyundai, Kia, Renault, Stellantis, KGM, Volkswagen, Tesla and Volvo - covering high-voltage and low-voltage components as well as electronics. The defence scope runs to MIL-STD-461D, MIL-STD-167-1 for mechanical vibration, RTCA DO-160G, MIL-PRF-28800F for test equipment and MIL-STD-1275E for vehicle power, served by large and extra-large walk-in chambers. Nuclear work is to US Regulatory Guide 1.180, the NRC guidance on EMC qualification of safety-related instrumentation - a scope almost unique in this directory. Battery testing covers UN 38.3, IEC 62619 and UN-ECE R100, with penetration, overcharge and thermal runaway tests, and cybersecurity and functional safety assessment sit alongside. It holds KOLAS-accredited calibration to ISO/IEC 17025 and supports KC, CE, FCC, UL, CB and Japanese certification, listing market access across more than two hundred countries including VCCI, PSE, MIC, CCC, SRRC, NOM, IFETEL, UKCA, EAC, ANATEL, SDPPI, NCC, ICASA, RCM and CSA. Its United States subsidiary HCT America in Milpitas, California is separately recognised by RRA under the APEC arrangement for testing to Korean radio and EMC standards. Specialisations are automotive electronics for global OEMs, nuclear instrumentation EMC, defence and aerospace, battery safety, and global market access.

Accreditations

Accreditation
ISO/IEC 17025
KCC (Korea)
FCC Listed
FCC Certified
ISED (Canada)
VCCI (Japan)
BSMI (Taiwan)
IECEE CB Scheme
APEC MRA

Testing Services

Test TypeApplicable Standards
Radiated EmissionsKN 32, KN 11, CISPR 32, CISPR 11, CISPR 25, FCC Part 15B, FCC Part 15C, VCCI-CISPR 32, MIL-STD-461D RE102, RTCA DO-160G Section 21, Regulatory Guide 1.180
Conducted EmissionsKN 32, KN 11, CISPR 32, CISPR 11, CISPR 25, FCC Part 15B, VCCI-CISPR 32, MIL-STD-461D CE101, MIL-STD-461D CE102, RTCA DO-160G Section 21, Regulatory Guide 1.180
Radiated ImmunityKN 35, CISPR 35, IEC 61000-4-3, ISO 11452-2, MIL-STD-461D RS103, RTCA DO-160G Section 20, Regulatory Guide 1.180
Conducted ImmunityKN 35, CISPR 35, IEC 61000-4-6, ISO 11452-4, MIL-STD-461D CS114, Regulatory Guide 1.180
Radiated SusceptibilityMIL-STD-461D RS101, MIL-STD-461D RS103, ISO 11452-2, RTCA DO-160G Section 20
Conducted SusceptibilityMIL-STD-461D CS101, MIL-STD-461D CS114, MIL-STD-461D CS115, MIL-STD-461D CS116, ISO 7637-2, MIL-STD-1275E
ESDIEC 61000-4-2, KN 61000-4-2, ISO 10605, Regulatory Guide 1.180
EFT/BurstIEC 61000-4-4, KN 61000-4-4, Regulatory Guide 1.180
Surge ImmunityIEC 61000-4-5, KN 61000-4-5, Regulatory Guide 1.180
Harmonics & FlickerKN 61000-3-2, KN 61000-3-3, IEC 61000-3-2, IEC 61000-3-3
Voltage Dips/InterruptsIEC 61000-4-11, KN 61000-4-11, ISO 16750-2
Power Frequency Magnetic FieldIEC 61000-4-8, KN 61000-4-8, MIL-STD-461D RS101
Bulk Current Injection (BCI)ISO 11452-4, MIL-STD-461D CS114
Pre-Compliance TestingKN 32, CISPR 25, IEC 61000-4-3, MIL-STD-461D, Regulatory Guide 1.180
SAR TestingKS C IEC 62209-1, KS C IEC 62209-2, IEC 62209-1528, IEEE 1528, FCC KDB 447498, RSS-102
Radio Equipment TestingKorea Radio Wave Law technical regulations, KS X 3123, KS X 3142, FCC Part 15.247, FCC Part 15.407, RSS-247, ETSI EN 300 328, ETSI EN 301 489-1, ETSI EN 301 489-17
Wireless CoexistenceANSI C63.27, AAMI TIR69
Automotive Component EMCCISPR 25, ISO 11452-2, ISO 11452-4, ISO 7637-2, ISO 10605, ISO 16750-2, UN-ECE R10, UN-ECE R100
Automotive Vehicle-Level EMCUN-ECE R10, CISPR 12, ISO 11451-2
Automotive OEM SpecificationsHyundai EMC specifications, Kia EMC specifications, Renault EMC specifications, Stellantis EMC specifications, Volkswagen EMC specifications, Volvo EMC specifications, CISPR 25, ISO 11452 series
Military EMCMIL-STD-461D, MIL-STD-461F, MIL-STD-167-1, MIL-PRF-28800F
MIL-STD-461MIL-STD-461D, MIL-STD-461F
Military Power QualityMIL-STD-1275E, MIL-STD-704F
Commercial Aviation EMCRTCA DO-160G Section 20, RTCA DO-160G Section 21, RTCA DO-160G Section 22
Medical Device EMCIEC 60601-1-2, KS C IEC 60601-1-2, IEC 61326-2-6
Medical Device RegulatoryIEC 60601-1, ISO 13485, Korea MFDS medical device regulations
Environmental TestingIEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-14, IEC 60068-2-30, IEC 60068-2-78, IEC 60529, UN 38.3, IEC 62619, ISO 16750-4
Mechanical TestingIEC 60068-2-6, IEC 60068-2-27, IEC 60068-2-64, MIL-STD-167-1, ISO 16750-3
Product SafetyKC safety certification, IEC 62368-1, IEC 61010-1, IEC 60335-1, IEC 60601-1, IEC 62619, IEC 62133-2, IEC 61508, ISO 26262

Certifications / Marks

Certification
KC mark
CE
FCC
UL
IECEE CB Certificate
UKCA
VCCI
PSE
MIC (Japan)
CCC
SRRC
NOM
IFETEL
EAC
ANATEL
SDPPI
NCC
ICASA
RCM
CSA
KOLAS accredited calibration

Industries Served

Industry
Automotive
Aerospace & Defense
Military
Nuclear
Medical Devices
Energy & Power
Radio & Wireless
Telecommunications
Consumer Electronics
Information Technology

Major Equipment

Equipment
Large walk-in chamber (defence testing)
Extra-large walk-in chamber (defence testing)
EMC chambers for automotive, nuclear and commercial testing
SAR measurement system
OTA (over-the-air) test system
EMI receiver
Spectrum analyser
LISN
CDN
BCI injection probes
ESD simulator
EFT/burst generator
Surge generator
Automotive transient generator (ISO 7637)
Harmonics and flicker analyser
RF power amplifiers and immunity antennas
Battery test facilities (penetration, overcharge, thermal runaway)
Environmental reliability chambers
Mechanical vibration facilities (MIL-STD-167-1)
Nuclear instrumentation EMC test set-ups (Regulatory Guide 1.180)
KOLAS-accredited calibration laboratory
Cleanroom testing and facility monitoring system (FMS)
HCT America subsidiary, Milpitas, California (RRA-recognised, US0198)