EMC Latest
← Back to Labs Directory
ICMET Craiova - Electromagnetic Compatibility Testing

ICMET Craiova - Electromagnetic Compatibility Testing

Craiova, Dolj, Romania

+40 351 404 888

Bulevardul Decebal 118A, Craiova, Dolj, 200746, Romania

1 / 2

About

The EMC testing group of ICMET Craiova - the National Institute for Research, Development and Testing in Electrical Engineering - sits within the Electrical Testing Team of the institute's High Voltage Division on Decebal Boulevard in Craiova, southern Romania. Its semi-anechoic chamber was commissioned in 2000: an 8 by 4 by 4 metre shielded housing with a 3-metre measuring distance and a 1.5 by 1.5 metre uniform field area. ICMET is unusually candid about that chamber's limits, publishing pre-compliance rather than full-compliance tolerances of plus or minus 9.5 dB from 30 to 90 MHz, plus or minus 6.5 dB from 90 to 200 MHz and plus or minus 4 dB from 200 MHz to 18 GHz - which tells an engineer exactly what the chamber can and cannot be relied on for, and is more useful than an unqualified claim. Two further shielded enclosures support it: a 4 by 2 by 0.8 metre measuring chamber with better than 80 dB shielding effectiveness, and a 5725 by 2350 by 2625 millimetre screened room with better than 120 dB. A Helmholtz coil system reaching 2,450 millitesla handles magnetic field work. The institute publishes its instrument inventory by model, which is rare: a Rohde and Schwarz SMV 42 EMI receiver covering 9 kHz to 2.6 GHz, an SMY 02 signal generator to 2.08 GHz, a 100W1000M1 power amplifier from 80 MHz to 1 GHz, a CWG 4-412 combination wave generator to 4,500 V, an EFTG 4502 fast transient generator to 4,400 V, an ESDC 30 discharge simulator to 15 kV, NNB 41 single-phase and LT 32/C three-phase artificial networks, AMZ 41 and F-201 absorbing clamps, an HL 1000 hybrid antenna, a CL 55C click analyser, an HAR 100-1P harmonics and flicker analyser and EMR 20 and EnviroMentor field meters. Most immunity and emissions methods are RENAR accredited; a few radiated emission methods and IEC 61000-4-12 are marked in progress. Military work runs to MIL-STD-461E and automotive to the 2004/104/EC directive with ISO 11452 and ISO 7637 - note that these are superseded editions, so confirm current scope before relying on the published list. Specialisations are pre-compliance chamber testing with declared uncertainties, high-shielding screened enclosures, Helmholtz magnetic field work, EMF exposure measurement in substations and occupied buildings, and automotive and military immunity.

Accreditations

Accreditation
ISO/IEC 17025
EMC Directive 2014/30/EU

Testing Services

Test TypeApplicable Standards
Radiated EmissionsEN 55011, CISPR 11, EN 55022, CISPR 22, EN 55014-1 disturbance power 30-300 MHz, EN 55015 magnetic field 0.09-30 MHz, EN 55025, EN 55012, 2004/104/EC, MIL-STD-461E RE102, MIL-STD-461E RE103
Conducted EmissionsEN 55011, CISPR 11, EN 55014, CISPR 14, EN 55015, CISPR 15, EN 55022, CISPR 22, EN 55014-1 discontinuous disturbances 148.5 kHz-30 MHz, EN 55017, CISPR 17, MIL-STD-461E CE101, MIL-STD-461E CE102, ISO 7637
Radiated ImmunityEN 61000-4-3, IEC 61000-4-3, ISO 11452-2, ISO 11452-5, 2004/104/EC, MIL-STD-461E RS101
Conducted ImmunityEN 61000-4-6, IEC 61000-4-6, ISO 11452-4, MIL-STD-461E CS114, MIL-STD-461E CS116
Radiated SusceptibilityMIL-STD-461E RS101, ISO 11452-2, ISO 11452-5, EN 61000-4-3
Conducted SusceptibilityMIL-STD-461E CS101, MIL-STD-461E CS109, MIL-STD-461E CS114, MIL-STD-461E CS115, MIL-STD-461E CS116, ISO 7637-1, ISO 7637-2, ISO 7637-3, IEC 60839-10-1
ESDEN 61000-4-2, IEC 61000-4-2
EFT/BurstEN 61000-4-4, IEC 61000-4-4
Surge ImmunityEN 61000-4-5, IEC 61000-4-5, EN 61000-4-12
Harmonics & FlickerEN 61000-3-2, EN 61000-3-3, EN 61000-4-7
Voltage Dips/InterruptsEN 61000-4-11, IEC 61000-4-11
Power Frequency Magnetic FieldEN 61000-4-8, EN 61000-4-9, IEC 61000-4-8, IEC 61000-4-9
Bulk Current Injection (BCI)ISO 11452-4, MIL-STD-461E CS114
Pre-Compliance TestingEN 55011, EN 55022, EN 61000-4-3, ISO 11452-2, MIL-STD-461E
Military EMCMIL-STD-461E
MIL-STD-461MIL-STD-461E
Automotive Component EMC2004/104/EC, ISO 11452-1, ISO 11452-2, ISO 11452-4, ISO 11452-5, ISO 7637-1, ISO 7637-2, ISO 7637-3, EN 55025, EN 55012
Product Safety2004/40/EC, 1999/513/EC, EN 55017, IEC 60839-10-1, ICNIRP Guidelines

Certifications / Marks

Certification
CE
RENAR accredited test reports
EMF exposure assessment (2004/40/EC, 1999/513/EC)
Automotive ESA test evidence (2004/104/EC)

Industries Served

Industry
Automotive
Military
Aerospace & Defense
Industrial Equipment
Household Appliances
Lighting Products
Information Technology
Energy & Power
Medical Devices

Major Equipment

Equipment
Semi-anechoic chamber 8 x 4 x 4 m shielded housing, 3 m measuring distance (commissioned 2000)
Uniform field area 1.5 x 1.5 m
Declared pre-compliance tolerances +/-9.5 dB (30-90 MHz), +/-6.5 dB (90-200 MHz), +/-4 dB (200 MHz-18 GHz)
Measuring screened chamber 4 x 2 x 0.8 m, shielding effectiveness >80 dB
Screened room 5725 x 2350 x 2625 mm, shielding effectiveness >120 dB
Helmholtz coil system, 2,450 mT
EMI receiver SMV 42, 9 kHz - 2.6 GHz
Signal generator SMY 02, 9 kHz - 2.08 GHz
Power amplifier 100W1000M1, 80 MHz - 1 GHz
Combination wave generator CWG 4-412, 50 - 4,500 V
Electrical fast transient generator EFTG 4502, 200 - 4,400 V
ESD simulator ESDC 30, 0 - 15 kV
Voltage interruption simulator VIS 700, 0 - 280 V
Coupling/decoupling generator CDG 6000, 100 kHz - 266 MHz
Artificial networks NNB 41 (single-phase) and LT 32/C (three-phase), 9 kHz - 30 MHz
Absorbing clamps AMZ 41 (30 MHz - 1 GHz) and F-201 (300 MHz - 1 GHz)
Hybrid antenna HL 1000, 20 MHz - 1 GHz
Loop antenna TLA300, 9 kHz - 30 MHz
Spectrum analyser FSH 3, 100 kHz - 3 GHz
Click analyser CL 55C
Flicker and harmonics analyser HAR 100-1P, 50 Hz - 2 kHz
Field meters EMR 20 (100 kHz - 3 GHz) and EnviroMentor (0 - 1000 V/m)