IPS Corporation - Nagano EMC Center
Tatsuno, Nagano, Japan
+81 266-44-52002555-1 Ono Oshino, Tatsuno-cho, Kamiina-gun, Tatsuno, Nagano, 399-0601, Japan
Additional locations (2)
About
IPS Corporation was established on 1 June 1992 and runs its Nagano EMC Center at Ono in Tatsuno, Kamiina district, Nagano Prefecture, and it holds a place in Japanese EMC history: the Japan Accreditation Board accredited it in September 1997 under accreditation number RTL00010 as the first EMC test laboratory accredited in Japan, and customers describe using it since its open-area test site days more than thirty years ago. It added VLAC certificate VLAC-015 for medical electrical equipment safety testing in September 2015, again the first such accreditation issued, and it is VCCI-registered for conformity confirmation testing under registration A-0103. Its calibration laboratories are NVLAP-accredited to ISO/IEC 17025 under two separate codes - 200012-0 at the Nagano Calibration Center for antennas and immunity test equipment, and 200679-0 at the Tokyo Calibration Center for receivers, spectrum analysers, signal generators and field probes - which means the laboratory calibrates its own reference chain under US accreditation rather than sending it out. EMI measurement extends to 40 GHz, covering both FCC and Radio Equipment Directive requirements. The accredited standards list is the broadest of any Japanese laboratory here and is deepest in two areas. Medical is the first: IEC/EN 60601-1-2 plus roughly fourteen particular standards from 60601-2-2 through 60601-2-52, the ISO 80601-2-55, -2-56 and -2-61 series, IEC 80601-2-30, and the IEC 61326-2-6 in vitro diagnostics standard, all with JIS equivalents. Marine is the second: CISPR 11 for shipboard electrical installations, IEC 60945, IEC 60533, IACS UR E10 and the rules of ten classification societies - NK, LR, ABS, BV, DNV, GL, RINA, CCS, KR and RS. Beyond those it covers multimedia, IT, radio, lighting, household appliance, airborne DO-160G and gas detection scopes, human exposure assessment to IEC 62233 and 62311, harmonics and flicker including 61000-3-11 and -3-12, and the less common IEC 61000-4-13, -4-16, -4-17 and -4-29 immunity tests. A Shinyokohama Safety Center at Yokohama handles product safety. Specialisations are medical electrical equipment EMC and safety, marine classification society approval, EMI to 40 GHz, and accredited in-house calibration.
Accreditations
| Accreditation |
|---|
| ISO/IEC 17025 |
| NVLAP |
| VCCI (Japan) |
| FCC Listed |
Testing Services
| Test Type | Applicable Standards |
|---|---|
| Radiated Emissions | CISPR 11, EN 55011, CISPR 32, EN 55032, CISPR 22, EN 55022, CISPR 14-1, EN 55014-1, CISPR 15, EN 55015, CISPR 16-2-3, VCCI-CISPR 32, FCC Part 15B, FCC Part 15C, ANSI C63.4, ICES-003, IEC 61000-6-3, IEC 61000-6-4, IEC 60601-1-2, IEC 61326-1, IEC 60945, RTCA DO-160G Section 21 |
| Conducted Emissions | CISPR 11, EN 55011, CISPR 32, EN 55032, CISPR 22, EN 55022, CISPR 14-1, EN 55014-1, CISPR 15, EN 55015, CISPR 16-2-1, CISPR 16-2-2, VCCI-CISPR 32, FCC Part 15B, ANSI C63.4, ICES-003, IEC 61000-6-3, IEC 61000-6-4, IEC 60601-1-2, IEC 60945 |
| Radiated Immunity | IEC 61000-4-3, EN 61000-4-3, CISPR 35, EN 55035, CISPR 24, EN 55024, CISPR 14-2, EN 55014-2, IEC 61547, IEC 61000-6-1, IEC 61000-6-2, IEC 60601-1-2, IEC 61326-1, IEC 60945, EN 50270, EN 50370-2, RTCA DO-160G Section 20 |
| Conducted Immunity | IEC 61000-4-6, EN 61000-4-6, IEC 61000-4-16, CISPR 35, EN 55035, CISPR 24, EN 55024, CISPR 14-2, IEC 61000-6-1, IEC 61000-6-2, IEC 60601-1-2, IEC 61326-1, IEC 60945, EN 50270 |
| Conducted Susceptibility | IEC 61000-4-16, IEC 61000-4-17, IEC 61000-4-29, IEC 61000-4-6 |
| ESD | IEC 61000-4-2, EN 61000-4-2, IEC 60601-1-2, IEC 60945, RTCA DO-160G Section 25 |
| EFT/Burst | IEC 61000-4-4, EN 61000-4-4, IEC 60601-1-2, IEC 60945 |
| Surge Immunity | IEC 61000-4-5, EN 61000-4-5, IEC 60601-1-2, IEC 60945 |
| Harmonics & Flicker | IEC 61000-3-2, EN 61000-3-2, IEC 61000-3-3, EN 61000-3-3, IEC 61000-3-11, IEC 61000-3-12, IEC 61000-4-7, IEC 61000-4-13 |
| Voltage Dips/Interrupts | IEC 61000-4-11, EN 61000-4-11, IEC 61000-4-29, IEC 60601-1-2 |
| Power Frequency Magnetic Field | IEC 61000-4-8, EN 61000-4-8, IEC 60601-1-2 |
| Pre-Compliance Testing | CISPR 32, CISPR 11, IEC 61000-4-3, IEC 60601-1-2, VCCI-CISPR 32 |
| Radio Equipment Testing | ETSI EN 301 489-1, ETSI EN 301 489-3, ETSI EN 301 489-14, ETSI EN 301 489-17, ETSI EN 300 330-1, ETSI EN 300 330-2, ETSI EN 300 328, ETSI EN 302 291-1, ETSI EN 302 291-2, FCC Part 15C |
| RFID Assessment | ETSI EN 302 291-1, ETSI EN 302 291-2, ETSI EN 300 330-1, ETSI EN 300 330-2 |
| Medical Device EMC | IEC 60601-1-2, EN 60601-1-2, JIS T 0601-1-2, IEC 60601-2-2, IEC 60601-2-4, IEC 60601-2-10, IEC 60601-2-18, IEC 60601-2-25, IEC 60601-2-26, IEC 60601-2-27, IEC 60601-2-34, IEC 60601-2-37, IEC 60601-2-40, IEC 60601-2-47, IEC 60601-2-49, IEC 60601-2-52, ISO 80601-2-55, ISO 80601-2-56, ISO 80601-2-61, IEC 80601-2-30, IEC 61326-2-6 |
| Medical Device Regulatory | IEC 60601-1, JIS T 0601-1, Japan Pharmaceutical and Medical Device Act (PMD Act), IEC 61326-2-6 |
| Commercial Aviation EMC | RTCA DO-160G Section 19, RTCA DO-160G Section 20, RTCA DO-160G Section 21, RTCA DO-160G Section 25 |
| Environmental Testing | IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-30, IEC 60068-2-78, IEC 60529, IEC 60533, IEC 60945 |
| Product Safety | IEC 60601-1, JIS T 0601-1, IEC 62368-1, IEC 61010-1, IEC 60335-1, IEC 60598-1, IEC 62233, IEC 62311, EN 12198-1, EN 12198-2, EN 12198-3, EN 50270, EN 50370-1, IEC 60945, IACS UR E10 |
Certifications / Marks
| Certification |
|---|
| VCCI (A-0103) |
| FCC |
| CE |
| UKCA |
| JAB RTL00010 accredited test reports |
| VLAC-015 |
| NVLAP 200012-0 |
| NVLAP 200679-0 |
| Marine classification society approvals (NK, LR, ABS, BV, DNV, GL, RINA, CCS, KR, RS) |
| Japan designated medical device certification support |
Industries Served
| Industry |
|---|
| Medical Devices |
| Industrial Equipment |
| Information Technology |
| Consumer Electronics |
| Lighting Products |
| Household Appliances |
| Telecommunications |
| Radio & Wireless |
| Aerospace & Defense |
| Energy & Power |
| Multimedia |
Major Equipment
| Equipment |
|---|
| EMC test chambers (JAB-accredited, first accredited EMC laboratory in Japan, 1997) |
| Open-area test site heritage (in use over 30 years) |
| EMI measurement to 40 GHz |
| EMI receiver |
| Spectrum analyser |
| LISN |
| CDN |
| ESD simulator |
| EFT/burst generator |
| Surge generator |
| Harmonics and flicker analyser (IEC 61000-4-7, -4-13) |
| Common mode injection system (IEC 61000-4-16) |
| DC ripple and DC dip generators (IEC 61000-4-17, -4-29) |
| Power frequency magnetic field coil |
| RF immunity amplifiers and antennas |
| Medical electrical equipment test benches (IEC 60601 particular standards) |
| Marine equipment test facilities (IEC 60945, IEC 60533, IACS UR E10) |
| Human exposure assessment probes (IEC 62233, IEC 62311) |
| Nagano Calibration Center - NVLAP 200012-0 (antennas, immunity equipment) |
| Tokyo Calibration Center - NVLAP 200679-0 (receivers, spectrum analysers, signal generators, field probes) |
| Shinyokohama Safety Center product safety laboratory |