Jan Linders AB
More labs in this area: EMC testing in Sweden
Gothenburg, Västra Götaland, Sweden
+46 31 744 38 80Bror Nilssons gata 4, Gothenburg, Västra Götaland, 417 55, Sweden
About
Jan Linders AB is an independent commercial EMC measurement facility with over 25 years of experience, centrally located at Bror Nilssons gata 4 on Lindholmen in Gothenburg — a site celebrated in the Lindholmen Innovation District as 'spetsteknologi på historisk mark' (cutting-edge technology on historic ground). The main measurement hall MR1 is a 10 × 6 × 6 m semi-damped (halvdämpad) hall with a load-bearing plywood/metal floor, a 2 000 kg turntable, and a height-sweeping antenna from 1 to 4 m, providing a classic 3-metre test distance compliant with EN 61000-4-3 and alternative-site emission measurement. A new fully anechoic EMC chamber was commissioned in 2026, further strengthening Jan Linders' position as a complete EMC partner. An unshielded screen room (4.7 × 7 m) is used for transient and conducted immunity testing. Total measurement capability spans radiated emission 20 Hz–18 GHz, conducted emission 20 Hz–26.5 GHz, radiated immunity 9 kHz–6 GHz, magnetic field emission and immunity 20 Hz–150 kHz, conducted immunity 9 kHz–250 MHz, harmonics/flicker, burst, surge, ESD, power-frequency magnetic field, dips and voltage variations (32 A), automotive component EMC, MIL-STD, LVD, climate (−40 to +180 °C, 15–95 % RH), and vibration.
Testing Services
| Test Type | Applicable Standards |
|---|---|
| Radiated Emissions | 20 Hz–18 GHz, EN 55011, EN 55032, EN 55014-1, EN 55015, CISPR product standards, Alternative site measurement |
| Conducted Emissions | 20 Hz–26.5 GHz, EN 55011, EN 55032, CISPR 14-1 |
| Radiated Immunity | IEC/EN 61000-4-3, 9 kHz–6 GHz |
| Conducted Immunity | IEC/EN 61000-4-6, 9 kHz–250 MHz |
| ESD | IEC/EN 61000-4-2 |
| EFT/Burst | IEC/EN 61000-4-4 |
| Surge Immunity | IEC/EN 61000-4-5 |
| Harmonics & Flicker | IEC/EN 61000-3-2, IEC/EN 61000-3-3 |
| Voltage Dips/Interrupts | IEC/EN 61000-4-11, 32 A |
| Power Frequency Magnetic Field | IEC/EN 61000-4-8, 20 Hz–150 kHz (magnetic field emission and immunity) |
| Automotive Component EMC | CISPR 25, ISO 11452 series, ISO 7637, ISO 10605 |
| Military EMC | MIL-STD (equipment available) |
| Medical Device EMC | IEC/EN 60601-1-2, IEC/EN 61326 |
| Pre-Compliance Testing | — |
| Environmental Testing | Climate −40 to +180 °C, 15–95 % RH, Vibration testing |
| Product Safety | LVD 2014/35/EU, IEC safety standards |
Certifications / Marks
| Certification |
|---|
| CE |
Industries Served
| Industry |
|---|
| Aerospace & Defense |
| Automotive |
| Consumer Electronics |
| Industrial Equipment |
| Information Technology |
| Medical Devices |
| Military |
| Telecommunications |
Major Equipment
| Equipment |
|---|
| Semi-damped hall MR1 — 10×6×6 m, 2 000 kg turntable, 1–4 m antenna sweep, 3 m test distance |
| New fully anechoic EMC chamber (commissioned 2026) |
| Unshielded screen room 4.7×7 m — transient and conducted immunity |
| Climate chamber −40 to +180 °C, 15–95 % RH |
| Vibration equipment |
| Power supply 35 A/phase, 400 V / 63 A service, up to 100 A product-internal |