JET - Japan Electrical Safety & Environment Technology Laboratories, Yokohama EMC Test Center

JET - Japan Electrical Safety & Environment Technology Laboratories, Yokohama EMC Test Center

Yokohama, Kanagawa, Japan

+81 45-582-2504

1-12-30 Motomiya, Tsurumi-ku, Yokohama, Kanagawa, 230-0004, Japan

About

JET, the Japan Electrical Safety and Environment Technology Laboratories, is a Japanese public-interest foundation headquartered in Shibuya, Tokyo, and performs its EMC work at two sites - the Yokohama EMC Test Center at Motomiya in Tsurumi-ku, and a Kansai EMC Test Center. The Yokohama chamber specifications are published in full, which is rare and makes capacity easy to assess. Its 10-metre anechoic chamber measures 17.0 by 11.0 by 7.6 metres, supports both 3-metre and 10-metre measurement distances, and carries a 3-metre turntable rated to 3,000 kilograms with 10 kVA single-phase three-wire or 12 kVA single or three-phase supply - a three-tonne turntable puts large industrial plant, power conditioners and EV chargers within reach. Its 3-metre chamber is 8.1 by 5.1 by 5.25 metres with a 2-metre, 500-kilogram turntable at 4.0 kVA, a dedicated immunity chamber is 7.0 by 3.0 by 3.0 metres with a 1.2-metre, 250-kilogram turntable at 10 kVA, and three shielded rooms measure 8.0 by 4.0 by 4.1, 10.0 by 5.0 by 3.1 and 5.8 by 4.6 by 2.7 metres. The Kansai site adds a 3-metre chamber of 9.01 by 6.0 by 5.2 metres with a 2-metre, 500-kilogram turntable at 4.5 kVA and a 10.0 by 5.0 by 2.7 metre shielded room at 12 kVA. Yokohama has been VLAC-accredited since 1 December 2009 and an IECEE CB Testing Laboratory since 2006; Kansai since 1 December 2015 and 2018 respectively. JET is also a mandatory third-party conformity assessment body for the PSE mark, PSC, the JIS Mark and Radio Act technical regulations conformity certification, certifies controlled medical devices, and runs the S-JET, CMJ component registration, JET PVm, JET PV O&M, JET Robot, NRTL and ECHONET Lite schemes. Measurement covers emissions including disturbance power and large and small loop antenna magnetic field strength, and immunity including proximity magnetic field. Specialisations are large and heavy equipment EMC, solar power conditioners and storage systems including mega-solar, EV fast chargers, and combined PSE conformity assessment with EMC measurement.

Accreditations

Accreditation
ISO/IEC 17025
IECEE CB Scheme
VCCI (Japan)
MIC (Japan)

Testing Services

Test TypeApplicable Standards
Radiated EmissionsCISPR 11, CISPR 14-1, CISPR 15, CISPR 32, VCCI-CISPR 32, EN 55011, EN 55014-1, EN 55015, EN 55032, FCC Part 15B, FCC Part 18, IEC 61000-6-3, IEC 61000-6-4, CISPR 16-2-3, CISPR 16-2-2, KS C 9832
Conducted EmissionsCISPR 11, CISPR 14-1, CISPR 15, CISPR 32, VCCI-CISPR 32, EN 55011, EN 55014-1, EN 55015, EN 55032, FCC Part 15B, IEC 61000-6-3, IEC 61000-6-4, CISPR 16-2-1
Radiated ImmunityIEC 61000-4-3, EN 61000-4-3, CISPR 35, CISPR 14-2, EN 55035, EN 55014-2, IEC 61547, IEC 61000-6-1, IEC 61000-6-2, IEC 60601-1-2, IEC 61326-1
Conducted ImmunityIEC 61000-4-6, EN 61000-4-6, CISPR 35, CISPR 14-2, EN 55035, EN 55014-2, IEC 61000-6-1, IEC 61000-6-2, IEC 60601-1-2
ESDIEC 61000-4-2, EN 61000-4-2, IEC 60601-1-2
EFT/BurstIEC 61000-4-4, EN 61000-4-4, IEC 60601-1-2
Surge ImmunityIEC 61000-4-5, EN 61000-4-5, IEC 60601-1-2
Harmonics & FlickerIEC 61000-3-2, EN 61000-3-2, JIS C 61000-3-2, IEC 61000-3-3, EN 61000-3-3, IEC 61000-3-11, IEC 61000-3-12
Voltage Dips/InterruptsIEC 61000-4-11, EN 61000-4-11, IEC 61000-4-34, IEC 60601-1-2
Power Frequency Magnetic FieldIEC 61000-4-8, EN 61000-4-8, IEC 61000-4-39, IEC 60601-1-2
Pre-Compliance TestingVCCI-CISPR 32, CISPR 11, IEC 61000-4-3, IEC 61000-6-2
Radio Equipment TestingJapan Radio Act technical regulations, MIC Ordinance Article 2 (giteki), ARIB STD-T66, FCC Part 18
Automotive Component EMCCISPR 25, ISO 11452-2, ISO 7637-2, UN-ECE R10
Medical Device EMCIEC 60601-1-2, JIS T0601-1-2, IEC 61326-2-6
Medical Device RegulatoryJapan Pharmaceutical and Medical Device Act (PMD Act), IEC 60601-1, JIS T0601-1
Environmental TestingIEC 60529, IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-30, IEC 60068-2-78
Product SafetyJapan Electrical Appliance and Material Safety Act (PSE), Japan Consumer Product Safety Act (PSC), IEC 60335-1, JIS C 9335-1, IEC 62368-1, IEC 61010-1, IEC 60598-1, IEC 62109-1, IEC 62109-2, IEC 61851-1, IEC 60601-1, ISO 10218

Certifications / Marks

Certification
PSE (Diamond and Circle)
PSC
JIS Mark
S-JET
Giteki (Radio Act technical regulations conformity)
IECEE CB Certificate
CMJ component registration
JET PVm
JET PV O&M
JET Robot
NRTL
ECHONET Lite / AIF
Japan controlled medical device certification
VCCI
KC (Korea)

Industries Served

Industry
Household Appliances
Energy & Power
Medical Devices
Lighting Products
Information Technology
Multimedia
Automotive
Industrial Equipment
Consumer Electronics

Major Equipment

Equipment
Yokohama 10 m anechoic chamber 17.0 x 11.0 x 7.6 m, 3.0/10.0 m distance, 3.0 m turntable, 3,000 kg, 10-12 kVA
Yokohama 3 m anechoic chamber 8.1 x 5.1 x 5.25 m, 3.0 m distance, 2.0 m turntable, 500 kg, 4.0 kVA
Yokohama immunity chamber 7.0 x 3.0 x 3.0 m, 1.2 m turntable, 250 kg, 10 kVA
Yokohama shielded room A 8.0 x 4.0 x 4.1 m
Yokohama shielded room B 10.0 x 5.0 x 3.1 m
Yokohama shielded room C 5.8 x 4.6 x 2.7 m
Kansai 3 m anechoic chamber 9.01 x 6.0 x 5.2 m, 2.0 m turntable, 500 kg, 4.5 kVA
Kansai shielded room 1A 10.0 x 5.0 x 2.7 m, 12 kVA
EMI receiver
Spectrum analyser
LISN
CDN
Absorbing clamp for disturbance power measurement
Large and small loop antennas for magnetic field strength
ESD simulator
EFT/burst generator
Surge generator
Harmonics and flicker analyser
Power frequency and proximity magnetic field coils
RF immunity amplifiers and antennas
Insulating material evaluation laboratory
PV calibration and measurement facility
Air conditioning capacity measurement facility
IP ingress protection test rigs
Photometry laboratory