JET - Japan Electrical Safety & Environment Technology Laboratories, Yokohama EMC Test Center
Yokohama, Kanagawa, Japan
+81 45-582-25041-12-30 Motomiya, Tsurumi-ku, Yokohama, Kanagawa, 230-0004, Japan
About
JET, the Japan Electrical Safety and Environment Technology Laboratories, is a Japanese public-interest foundation headquartered in Shibuya, Tokyo, and performs its EMC work at two sites - the Yokohama EMC Test Center at Motomiya in Tsurumi-ku, and a Kansai EMC Test Center. The Yokohama chamber specifications are published in full, which is rare and makes capacity easy to assess. Its 10-metre anechoic chamber measures 17.0 by 11.0 by 7.6 metres, supports both 3-metre and 10-metre measurement distances, and carries a 3-metre turntable rated to 3,000 kilograms with 10 kVA single-phase three-wire or 12 kVA single or three-phase supply - a three-tonne turntable puts large industrial plant, power conditioners and EV chargers within reach. Its 3-metre chamber is 8.1 by 5.1 by 5.25 metres with a 2-metre, 500-kilogram turntable at 4.0 kVA, a dedicated immunity chamber is 7.0 by 3.0 by 3.0 metres with a 1.2-metre, 250-kilogram turntable at 10 kVA, and three shielded rooms measure 8.0 by 4.0 by 4.1, 10.0 by 5.0 by 3.1 and 5.8 by 4.6 by 2.7 metres. The Kansai site adds a 3-metre chamber of 9.01 by 6.0 by 5.2 metres with a 2-metre, 500-kilogram turntable at 4.5 kVA and a 10.0 by 5.0 by 2.7 metre shielded room at 12 kVA. Yokohama has been VLAC-accredited since 1 December 2009 and an IECEE CB Testing Laboratory since 2006; Kansai since 1 December 2015 and 2018 respectively. JET is also a mandatory third-party conformity assessment body for the PSE mark, PSC, the JIS Mark and Radio Act technical regulations conformity certification, certifies controlled medical devices, and runs the S-JET, CMJ component registration, JET PVm, JET PV O&M, JET Robot, NRTL and ECHONET Lite schemes. Measurement covers emissions including disturbance power and large and small loop antenna magnetic field strength, and immunity including proximity magnetic field. Specialisations are large and heavy equipment EMC, solar power conditioners and storage systems including mega-solar, EV fast chargers, and combined PSE conformity assessment with EMC measurement.
Accreditations
| Accreditation |
|---|
| ISO/IEC 17025 |
| IECEE CB Scheme |
| VCCI (Japan) |
| MIC (Japan) |
Testing Services
| Test Type | Applicable Standards |
|---|---|
| Radiated Emissions | CISPR 11, CISPR 14-1, CISPR 15, CISPR 32, VCCI-CISPR 32, EN 55011, EN 55014-1, EN 55015, EN 55032, FCC Part 15B, FCC Part 18, IEC 61000-6-3, IEC 61000-6-4, CISPR 16-2-3, CISPR 16-2-2, KS C 9832 |
| Conducted Emissions | CISPR 11, CISPR 14-1, CISPR 15, CISPR 32, VCCI-CISPR 32, EN 55011, EN 55014-1, EN 55015, EN 55032, FCC Part 15B, IEC 61000-6-3, IEC 61000-6-4, CISPR 16-2-1 |
| Radiated Immunity | IEC 61000-4-3, EN 61000-4-3, CISPR 35, CISPR 14-2, EN 55035, EN 55014-2, IEC 61547, IEC 61000-6-1, IEC 61000-6-2, IEC 60601-1-2, IEC 61326-1 |
| Conducted Immunity | IEC 61000-4-6, EN 61000-4-6, CISPR 35, CISPR 14-2, EN 55035, EN 55014-2, IEC 61000-6-1, IEC 61000-6-2, IEC 60601-1-2 |
| ESD | IEC 61000-4-2, EN 61000-4-2, IEC 60601-1-2 |
| EFT/Burst | IEC 61000-4-4, EN 61000-4-4, IEC 60601-1-2 |
| Surge Immunity | IEC 61000-4-5, EN 61000-4-5, IEC 60601-1-2 |
| Harmonics & Flicker | IEC 61000-3-2, EN 61000-3-2, JIS C 61000-3-2, IEC 61000-3-3, EN 61000-3-3, IEC 61000-3-11, IEC 61000-3-12 |
| Voltage Dips/Interrupts | IEC 61000-4-11, EN 61000-4-11, IEC 61000-4-34, IEC 60601-1-2 |
| Power Frequency Magnetic Field | IEC 61000-4-8, EN 61000-4-8, IEC 61000-4-39, IEC 60601-1-2 |
| Pre-Compliance Testing | VCCI-CISPR 32, CISPR 11, IEC 61000-4-3, IEC 61000-6-2 |
| Radio Equipment Testing | Japan Radio Act technical regulations, MIC Ordinance Article 2 (giteki), ARIB STD-T66, FCC Part 18 |
| Automotive Component EMC | CISPR 25, ISO 11452-2, ISO 7637-2, UN-ECE R10 |
| Medical Device EMC | IEC 60601-1-2, JIS T0601-1-2, IEC 61326-2-6 |
| Medical Device Regulatory | Japan Pharmaceutical and Medical Device Act (PMD Act), IEC 60601-1, JIS T0601-1 |
| Environmental Testing | IEC 60529, IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-30, IEC 60068-2-78 |
| Product Safety | Japan Electrical Appliance and Material Safety Act (PSE), Japan Consumer Product Safety Act (PSC), IEC 60335-1, JIS C 9335-1, IEC 62368-1, IEC 61010-1, IEC 60598-1, IEC 62109-1, IEC 62109-2, IEC 61851-1, IEC 60601-1, ISO 10218 |
Certifications / Marks
| Certification |
|---|
| PSE (Diamond and Circle) |
| PSC |
| JIS Mark |
| S-JET |
| Giteki (Radio Act technical regulations conformity) |
| IECEE CB Certificate |
| CMJ component registration |
| JET PVm |
| JET PV O&M |
| JET Robot |
| NRTL |
| ECHONET Lite / AIF |
| Japan controlled medical device certification |
| VCCI |
| KC (Korea) |
Industries Served
| Industry |
|---|
| Household Appliances |
| Energy & Power |
| Medical Devices |
| Lighting Products |
| Information Technology |
| Multimedia |
| Automotive |
| Industrial Equipment |
| Consumer Electronics |
Major Equipment
| Equipment |
|---|
| Yokohama 10 m anechoic chamber 17.0 x 11.0 x 7.6 m, 3.0/10.0 m distance, 3.0 m turntable, 3,000 kg, 10-12 kVA |
| Yokohama 3 m anechoic chamber 8.1 x 5.1 x 5.25 m, 3.0 m distance, 2.0 m turntable, 500 kg, 4.0 kVA |
| Yokohama immunity chamber 7.0 x 3.0 x 3.0 m, 1.2 m turntable, 250 kg, 10 kVA |
| Yokohama shielded room A 8.0 x 4.0 x 4.1 m |
| Yokohama shielded room B 10.0 x 5.0 x 3.1 m |
| Yokohama shielded room C 5.8 x 4.6 x 2.7 m |
| Kansai 3 m anechoic chamber 9.01 x 6.0 x 5.2 m, 2.0 m turntable, 500 kg, 4.5 kVA |
| Kansai shielded room 1A 10.0 x 5.0 x 2.7 m, 12 kVA |
| EMI receiver |
| Spectrum analyser |
| LISN |
| CDN |
| Absorbing clamp for disturbance power measurement |
| Large and small loop antennas for magnetic field strength |
| ESD simulator |
| EFT/burst generator |
| Surge generator |
| Harmonics and flicker analyser |
| Power frequency and proximity magnetic field coils |
| RF immunity amplifiers and antennas |
| Insulating material evaluation laboratory |
| PV calibration and measurement facility |
| Air conditioning capacity measurement facility |
| IP ingress protection test rigs |
| Photometry laboratory |