
KRIWAN Testzentrum GmbH
Forchtenberg, Baden-Wuerttemberg, Germany
+49 7947 9150-0Teslastrasse 2, Forchtenberg, Baden-Wuerttemberg, 74670, Germany
About
KRIWAN Testzentrum, founded in 1997 at Forchtenberg in northern Baden-Wuerttemberg as the testing arm of the KRIWAN group, has grown into one of Germany's broader multi-sector compliance houses, combining EMC, environmental simulation, fire detection technology and construction product certification on one site. Its EMC facilities comprise a shielded cabin plus anechoic chambers configured for both the 3 metre and 10 metre measurement distances, with measurement to 6 GHz, radiated immunity fields to 400 V/m and magnetic field generation to 1000 A/m. DAkkS accreditation is held under D-PL-12091-01-00 with partial scopes -01-01 and -01-02 covering electromagnetic compatibility, environmental testing and fire detection technology, and the centre is a designated Technical Service of the German Federal Motor Transport Authority in categories A and D under KBA-P00042, which lets it issue E-mark test reports for UN-ECE R10 Rev. 6 and the agricultural and non-road directives 2009/64/EC, 2005/30/EC and 2009/19/EC. It is additionally a DAkkS-accredited certification body for construction products (D-ZE-12091-01-00) and a DIBt notified body (NB 1772), and holds permission under the German Explosives Act to handle pyrotechnic articles - the reason it can test airbag and restraint components. Accredited standards span automotive (CISPR 25, ISO 7637-2/-3, ISO 11452-2/-4/-5/-8/-9, ISO 10605, ISO 16750-2), agricultural, forestry and construction machinery (ISO 14982, ISO 15003, ISO 13766-1/-2), railway (EN 50155, EN 50121-3-2), fire and alarm systems (EN 50130-4, EN 54-25), marine and offshore (EN 60945 with ABS, BV and DNV type approval routes) and the industrial EN 61000-6 generic series. Specialisations are compressor and motor protection electronics, off-highway and agricultural machinery, fire detection systems, and marine equipment.
Accreditations
| Accreditation |
|---|
| ISO/IEC 17025 |
| DAkkS |
| ISO/IEC 17065 |
| EMC Directive 2014/30/EU |
Testing Services
| Test Type | Applicable Standards |
|---|---|
| Radiated Emissions | CISPR 25, CISPR 11, EN 55011, EN 61000-6-3, EN 61000-6-4, ISO 14982, ISO 13766-1, EN 50121-3-2, EN 60945, UN-ECE R10 |
| Conducted Emissions | CISPR 25, CISPR 11, EN 55011, EN 61000-6-3, EN 61000-6-4, EN 50121-3-2, EN 60945 |
| Radiated Immunity | IEC 61000-4-3, EN 61000-4-3, ISO 11452-2, ISO 11452-9, ISO 14982, ISO 13766-1, EN 50130-4, EN 61000-6-1, EN 61000-6-2, EN 60945, UN-ECE R10 |
| Conducted Immunity | IEC 61000-4-6, EN 61000-4-6, ISO 11452-4, EN 50130-4, EN 61000-6-1, EN 61000-6-2, EN 60945 |
| Radiated Susceptibility | ISO 11452-2, ISO 11452-3, ISO 11452-5, ISO 11452-8, ISO 11452-9 |
| Conducted Susceptibility | ISO 11452-4, ISO 7637-2, ISO 7637-3 |
| ESD | ISO 10605, IEC 61000-4-2, EN 61000-4-2, EN 50130-4 |
| EFT/Burst | IEC 61000-4-4, EN 61000-4-4, EN 50130-4 |
| Surge Immunity | IEC 61000-4-5, EN 61000-4-5, EN 50130-4 |
| Harmonics & Flicker | IEC 61000-3-2, EN 61000-3-2, IEC 61000-3-3, EN 61000-3-3 |
| Voltage Dips/Interrupts | IEC 61000-4-11, EN 61000-4-11, IEC 61000-4-29, EN 50130-4, ISO 16750-2 |
| Power Frequency Magnetic Field | IEC 61000-4-8, EN 61000-4-8, ISO 11452-8 |
| Bulk Current Injection (BCI) | ISO 11452-4, ISO 13766-1 |
| Pre-Compliance Testing | CISPR 25, ISO 11452-2, ISO 11452-4, EN 61000-6-2, UN-ECE R10 |
| Automotive Component EMC | CISPR 25, ISO 7637-2, ISO 7637-3, ISO 11452-2, ISO 11452-4, ISO 11452-5, ISO 11452-8, ISO 11452-9, ISO 10605, ISO 16750-2 |
| Automotive OEM Specifications | UN-ECE R10 Rev. 6, 2009/19/EC, 2005/30/EC, 2009/64/EC, CISPR 25, ISO 11452 series |
| Railway EMC | EN 50121-3-2, EN 50155 |
| Environmental Testing | IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-14, IEC 60068-2-30, IEC 60068-2-78, ISO 16750-4, IEC 60529 |
| Mechanical Testing | IEC 60068-2-6, IEC 60068-2-27, IEC 60068-2-64, ISO 16750-3 |
| Product Safety | EN 54-25, EN 50130-4, EN 60730-1, EN 61010-1 |
Certifications / Marks
| Certification |
|---|
| CE |
| UN-ECE E-mark |
| DIBt approval (NB 1772) |
| ABS type approval |
| BV type approval |
| DNV type approval |
Industries Served
| Industry |
|---|
| Automotive |
| Agricultural & Forestry |
| Railway |
| Industrial Equipment |
| Energy & Power |
| Consumer Electronics |
| Household Appliances |
Major Equipment
| Equipment |
|---|
| Anechoic chamber with 10 m measurement distance |
| Anechoic chamber with 3 m measurement distance |
| Shielded cabin |
| Measurement capability to 6 GHz |
| Radiated immunity field to 400 V/m |
| Magnetic field generation to 1000 A/m |
| EMI receiver |
| Spectrum analyser |
| LISN |
| CDN |
| BCI injection probes |
| ESD simulator to ISO 10605 |
| EFT/burst generator |
| Surge generator |
| Automotive transient generator (ISO 7637) |
| Harmonics and flicker analyser |
| Climatic and temperature-shock chambers |
| Vibration and shock rigs |
| IP ingress protection test rigs |
| Pyrotechnic-rated test bunker for airbag and restraint components |
| Fire detection and alarm system test rigs |





