KTR - Korea Testing & Research Institute
Gwacheon, Gyeonggi-do, South Korea
+82 2-2164-001198 Gyoyukwon-ro, Gwacheon, Gyeonggi-do, 13810, South Korea
About
The Korea Testing and Research Institute, KTR, has its headquarters on Gyoyukwon-ro in Gwacheon-si, Gyeonggi-do, and is a KOLAS-accredited national testing body and a designated conformity assessment institute for broadcasting and communications equipment under the National Radio Research Agency, with EMC testing under KOLAS certification standard 03.011. Its EMC capability is published in more technical detail than any other Korean laboratory in this directory. The main asset is a 10-metre radiation chamber measuring 19.8 by 12.2 by 9.1 metres, covering 150 kHz to 18 GHz, with a 3-metre turntable rated to 3 tonnes and an antenna mast travelling from 1 to 4 metres. Around it sits an instrument set aimed squarely at defence and aerospace: a lightning induction tester with multiple-stroke, single-stroke and multiple-burst generators for indirect lightning testing on aircraft; M-CS115 and POG-CS116-6 pulse generators at 2 kV and 15 kV charging voltage over 10 kHz to 100 MHz; an EFG-03 E-field generator at 3.5 kW from 10 kHz to 100 MHz; HPBA-2510 broadband and VAL-8001 log-periodic antennas; and a PAS30000 power simulation system supplying 135 or 270 V AC under 125 A and DC to 5 kHz. Most distinctive of all are EMP pulse generators - EMP80K-5/500 and EMP300K-5/500 - producing 10 to 80 kV and 100 to 350 kV open-circuit voltage, used for EMP protection facility verification to MIL-STD-188-125-1 and -2, the Korean defence standard DMFC 4-40-70 and IEEE 299 and 299.1 shielding effectiveness. Beyond defence it covers automotive to CISPR, IEC, ECE, SAE and ISO plus manufacturer specifications, railway to the EN 50121 and IEC 62236 series, ships to IEC 60945 and 60533 with KR, DNV and Lloyd's Register classification standards, and home and industrial equipment to KN 15, KN 61547, EN 12015 and EN 12016 lift standards, EN 61800-3 and KS C IEC 62040-2 for UPS. Specialisations are EMP protection facility verification, aircraft lightning induction testing, 3-tonne turntable large-equipment measurement, and marine classification EMC.
Accreditations
| Accreditation |
|---|
| ISO/IEC 17025 |
| KCC (Korea) |
| IECEE CB Scheme |
Testing Services
| Test Type | Applicable Standards |
|---|---|
| Radiated Emissions | KN 15, KN 32, CISPR 11, CISPR 32, EN 55014-1, EN 50121-3-2, IEC 62236-3-2, IEC 60945, MIL-STD-461 RE102, RTCA DO-160, EN 61800-3, EN 12015 |
| Conducted Emissions | KN 15, KN 32, CISPR 11, CISPR 32, EN 55014-1, IEC 60945, MIL-STD-461 CE101, MIL-STD-461 CE102, RTCA DO-160, EN 61800-3, KS C IEC 62040-2 |
| Radiated Immunity | KN 61547, EN 55014-2, IEC 61000-4-3, EN 50121-4, IEC 62236-4, IEC 60945, MIL-STD-461 RS103, RTCA DO-160, EN 12016, EN 61800-3 |
| Conducted Immunity | EN 55014-2, IEC 61000-4-6, EN 50121-4, IEC 62236-4, IEC 60945, MIL-STD-461 CS114, EN 12016 |
| Radiated Susceptibility | MIL-STD-461 RS101, MIL-STD-461 RS103, MIL-STD-461 RS105, RTCA DO-160 |
| Conducted Susceptibility | MIL-STD-461 CS101, MIL-STD-461 CS114, MIL-STD-461 CS115, MIL-STD-461 CS116, ISO 7637-2, SAE specifications |
| ESD | IEC 61000-4-2, KN 61000-4-2, ISO 10605, IEC 60945 |
| EFT/Burst | IEC 61000-4-4, KN 61000-4-4, IEC 60945 |
| Surge Immunity | IEC 61000-4-5, KN 61000-4-5, IEC 60945 |
| Harmonics & Flicker | KN 61000-3-2, KN 61000-3-3, IEC 61000-3-2, IEC 61000-3-3, IEC 61000-3-11, IEC 61000-3-12 |
| Voltage Dips/Interrupts | IEC 61000-4-11, KN 61000-4-11, KS C IEC 62040-2 |
| Power Frequency Magnetic Field | IEC 61000-4-8, IEC 61000-4-9, MIL-STD-461 RS101 |
| Bulk Current Injection (BCI) | ISO 11452-4, MIL-STD-461 CS114 |
| Pre-Compliance Testing | KN 32, CISPR 11, MIL-STD-461, IEC 61000-4-3, IEC 60945 |
| Military EMC | MIL-STD-461, MIL-STD-188-125-1, MIL-STD-188-125-2, DMFC 4-40-70 |
| MIL-STD-461 | MIL-STD-461E, MIL-STD-461F, MIL-STD-461G |
| Military Power Quality | MIL-STD-704F, MIL-STD-1275E |
| Commercial Aviation EMC | RTCA DO-160G Section 20, RTCA DO-160G Section 21, RTCA DO-160G Section 22, RTCA DO-160G Section 23 |
| Automotive Component EMC | CISPR 25, ISO 11452-2, ISO 11452-4, ISO 7637-2, ISO 10605, UN-ECE R10, SAE J1113 |
| Automotive OEM Specifications | Vehicle manufacturer specifications, CISPR 25, ISO 11452 series, SAE J1113 series |
| Railway EMC | EN 50121-3-2, EN 50121-4, EN 50121-5, IEC 62236-3-2, IEC 62236-4, IEC 62236-5 |
| Environmental Testing | IEEE Std 299, IEEE Std 299.1, IEC 60068-2-1, IEC 60068-2-2, IEC 60529, IEC 60533 |
| Product Safety | KC safety certification, IEC 60945, IEC 60533, IEC 62368-1, IEC 61010-1, IEEE Std 299, IEEE Std 299.1, KS C IEC 62040-2, EN 12015, EN 12016 |
Certifications / Marks
| Certification |
|---|
| KC mark |
| CE |
| KS mark |
| CR-Mark |
| PSE |
| C-Tick / RCM |
| IECEE CB Certificate |
| CCC |
| KOLAS accredited test reports (standard 03.011) |
| RRA designated conformity assessment institute |
| Marine classification society support (KR, DNV, Lloyd's Register) |
Industries Served
| Industry |
|---|
| Aerospace & Defense |
| Military |
| Automotive |
| Railway |
| Industrial Equipment |
| Household Appliances |
| Energy & Power |
| Telecommunications |
| Consumer Electronics |
| Information Technology |
Major Equipment
| Equipment |
|---|
| 10 m radiation chamber 19.8 x 12.2 x 9.1 m, 150 kHz - 18 GHz |
| 3 m turntable rated to 3 tonnes, antenna mast 1 - 4 m |
| Lightning induction tester: multiple-stroke, single-stroke and multiple-burst generators (aircraft indirect lightning) |
| Pulse generators M-CS115 and POG-CS116-6: 2 kV / 15 kV charging voltage, 10 kHz - 100 MHz |
| E-field generator EFG-03: 10 kHz - 100 MHz, 3.5 kW |
| Broadband antenna HPBA-2510: 25 - 100 MHz, 3.5 kW |
| V-log periodic antenna VAL-8001: 80 MHz - 1 GHz, 8 dBi gain |
| EMP pulse generator EMP80K-5/500: 10 - 80 kV open-circuit voltage |
| EMP pulse generator EMP300K-5/500: 100 - 350 kV open-circuit voltage |
| Power simulation system PAS30000: AC 135/270 Vrms under 125 A, DC to 5 kHz |
| EMI receiver |
| Spectrum analyser |
| LISN |
| CDN |
| BCI injection probes |
| ESD simulator |
| EFT/burst generator |
| Surge generator |
| Harmonics and flicker analyser |
| EMP protection facility verification equipment (MIL-STD-188-125) |
| Shielding effectiveness measurement (IEEE 299, 299.1) |