LEITC - Latvian Electronic Equipment Testing Centre
About
LEITC, the Latvian Electronic Equipment Testing Centre, occupies premises on Azenes iela on the Kipsala island campus in Riga and was established by LETERA, the Latvian Electrical Engineering and Electronics Industry Association, together with industry partners - so it exists as shared national infrastructure for an electronics sector that previously had to send work abroad. It is accredited to ISO/IEC 17025 by LATAK, the Latvian National Accreditation Bureau, under scope reference LEITC-R-01 covering 64 electronic and electrical equipment standards, and holds ISO 9001. Its single semi-anechoic chamber is specified in detail: 8.5 by 5.0 by 5.75 metres internally, measuring to 40 GHz, with a 1.5-metre motorised turntable rated to 1,000 kilograms, a floor loading of 1,000 kilograms per square metre, and an automatic pneumatic latching door 1,238 by 1,968 millimetres. Power inside the chamber is a 2x16 A and a 3x32 A supply at 250 V, 50 Hz, and the chamber is monitored by smoke detector, emergency lamp, CCTV and two-way audio. A shielded amplifier room and a shielded control room sit alongside it. The accredited standards lean heavily toward radio: the ETSI EN 301 489 series parts 1, 3 and 17 across multiple versions, EN 300 330 and EN 300 440. Four service lines are unusual for a laboratory of this size and worth noting: three-dimensional antenna measurements, drone and unmanned aerial vehicle platform testing, military EMC testing, and market surveillance work - the last meaning LEITC tests products already on sale on behalf of regulators, not only pre-market samples. FCC testing, low voltage directive testing and temperature testing complete the scope, and certificates of conformity are issued in cooperation with a notified body where the route requires one, since LEITC is not itself a notified body. More than 25 years of accumulated international experience stand behind it. Specialisations are radio equipment EMC, 3D antenna measurement, drone and UAV platforms, military EMC and market surveillance testing for the Baltic electronics industry.
Accreditations
| Accreditation |
|---|
| ISO/IEC 17025 |
Testing Services
| Test Type | Applicable Standards |
|---|---|
| Radiated Emissions | CISPR 11, EN 55011, CISPR 15, EN 55015, CISPR 32, EN 55032, EN 55022, FCC Part 15B, FCC Part 15C, ANSI C63.4, EN 61000-6-3, EN 61000-6-4 |
| Conducted Emissions | CISPR 11, EN 55011, CISPR 15, EN 55015, CISPR 32, EN 55032, EN 55022, FCC Part 15B, ANSI C63.4, EN 61000-6-3, EN 61000-6-4 |
| Radiated Immunity | IEC 61000-4-3, EN 61000-4-3, EN 55024, EN 55035, EN 61000-6-1, EN 61000-6-2, ETSI EN 301 489-1 |
| Conducted Immunity | IEC 61000-4-6, EN 61000-4-6, EN 55024, EN 55035, EN 61000-6-1, EN 61000-6-2, ETSI EN 301 489-1 |
| Radiated Susceptibility | MIL-STD-461G RS103, IEC 61000-4-3 |
| Conducted Susceptibility | MIL-STD-461G CS114, IEC 61000-4-6 |
| ESD | IEC 61000-4-2, EN 61000-4-2, ETSI EN 301 489-1 |
| EFT/Burst | IEC 61000-4-4, EN 61000-4-4 |
| Surge Immunity | IEC 61000-4-5, EN 61000-4-5 |
| Harmonics & Flicker | IEC 61000-3-2, EN 61000-3-2, IEC 61000-3-3, EN 61000-3-3 |
| Voltage Dips/Interrupts | IEC 61000-4-11, EN 61000-4-11 |
| Power Frequency Magnetic Field | IEC 61000-4-8, EN 61000-4-8 |
| Pre-Compliance Testing | CISPR 32, CISPR 11, IEC 61000-4-3, FCC Part 15B, ETSI EN 301 489-1 |
| Radio Equipment Testing | ETSI EN 301 489-1 V1.9.2, ETSI EN 301 489-1 V2.1.1, ETSI EN 301 489-1 V2.2.3, ETSI EN 301 489-3 V1.6.1, ETSI EN 301 489-17 V2.2.1, ETSI EN 301 489-17 V3.1.1, ETSI EN 301 489-17 V3.2.4, ETSI EN 301 489-17 V3.3.1, ETSI EN 300 330 V2.1.1, ETSI EN 300 440-1 V1.6.1, ETSI EN 300 328, FCC Part 15.247 |
| Military EMC | MIL-STD-461F, MIL-STD-461G |
| MIL-STD-461 | MIL-STD-461F, MIL-STD-461G |
| Environmental Testing | IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-14, IEC 60068-2-30, IEC 60068-2-78 |
| Product Safety | EN 62368-1, EN 60335-1, EN 61010-1, Directive 2014/35/EU |
Certifications / Marks
| Certification |
|---|
| CE |
| FCC |
| Certificate of Conformity (issued with a notified body) |
| ISO 9001 |
| LATAK accreditation scope LEITC-R-01 |
Industries Served
| Industry |
|---|
| Consumer Electronics |
| Radio & Wireless |
| Telecommunications |
| Household Appliances |
| Industrial Equipment |
| Aerospace & Defense |
| Military |
| Information Technology |
Major Equipment
| Equipment |
|---|
| Semi-anechoic chamber 8.5 x 5.0 x 5.75 m internal, measurement to 40 GHz |
| Motorised turntable 1.5 m diameter, 1,000 kg maximum load |
| Chamber floor loading 1,000 kg/m2 |
| Automatic pneumatic latching door 1,238 x 1,968 mm |
| In-chamber power: 2x16 A and 3x32 A at 250 V, 50 Hz |
| Chamber monitoring: smoke detector, emergency lamp, CCTV, loudspeaker and microphone |
| Shielded amplifier room |
| Shielded control room |
| 3D antenna measurement set-up |
| Drone and UAV platform test set-up |
| EMI receiver |
| Spectrum analyser |
| LISN |
| CDN |
| ESD simulator |
| EFT/burst generator |
| Surge generator |
| Harmonics and flicker analyser |
| RF power amplifiers and immunity antennas |
| Temperature test chambers |
| Low voltage directive safety test equipment |