EMC Latest
← Back to Labs Directory
MiTAC EMC Lab

MiTAC EMC Lab

Taoyuan, Taoyuan, Taiwan

+886-3-327-5988 ext. 1830

No. 200, Wen Hwa 2nd Rd., Guishan Dist., Taoyuan, Taoyuan, 333611, Taiwan

About

MiTAC EMC Lab is an independent EMC test laboratory at No. 200, Wen Hwa 2nd Rd., Guishan District, Taoyuan, on MiTAC's Taoyuan campus, set up in 2000 and recognised by leading first-tier ITE manufacturers. It concentrates on data-center servers, PCs, network equipment, power supply units and embedded computing devices, and is equipped with a world-class ETS-Lindgren anechoic chamber (largest chamber 10 m) and a high-power test environment rated at 20 kW DC (0–380 Vdc) and 10 kW AC (5–300 Vac) — capability that matters for rack-scale and high-power equipment that many general-purpose labs cannot power. Accredited to ISO/IEC 17025:2017 since 30 April 2019 (TAF 3021), the lab also holds FCC (TW1080), VCCI (C-11173, R-11114, T-11551, G-10021), BSMI (SL2-IN-E-0063) and NVLAP (lab code 500064-0) recognition. Services include pre-compliance radiated/conducted emission and immunity testing with debugging and retrofitting in an on-site electronics workshop, final certification testing for BSMI, CE, FCC, IC, VCCI, CCC, KC and RCM, expedited BSMI certification, NEBS pre-compliance for telco products, and EMC design review and troubleshooting consulting.

Accreditations

Accreditation
ISO/IEC 17025
NVLAP
FCC Listed
BSMI (Taiwan)
VCCI (Japan)

Testing Services

Test TypeApplicable Standards
Radiated EmissionsFCC Part 15 Subpart B, VCCI, ICES-003, CNS 15936 (BSMI), CE-EMC, 10 m ETS-Lindgren anechoic chamber
Conducted EmissionsFCC Part 15 Subpart B, VCCI, CNS 15936 (BSMI), CE-EMC
Radiated ImmunityIEC/EN 61000-4-3, EN 55035
Conducted ImmunityIEC/EN 61000-4-6
ESDIEC/EN 61000-4-2
Surge ImmunityIEC/EN 61000-4-5
Voltage Dips/InterruptsIEC/EN 61000-4-11
Pre-Compliance TestingNEBS pre-compliance (telco products), High-power equipment pre-scan: 20 kW DC / 10 kW AC, EMC design review and troubleshooting

Certifications / Marks

Certification
BSMI
CE
FCC
ISED
VCCI
CCC
KC
RCM

Industries Served

Industry
Consumer Electronics
Information Technology
Medical Devices
Telecommunications

Major Equipment

Equipment
ETS-Lindgren anechoic chamber (largest chamber 10 m)
High-power test environment: DC 20 kW (0–380 Vdc), AC 10 kW (5–300 Vac)
Electronics workshop for EMC debugging and retrofitting