Qamcom Research and Technology AB
More labs in this area: EMC testing in Sweden
Gothenburg, Västra Götaland, Sweden
Gothenburg, Västra Götaland, Sweden
Additional locations (2)
About
Qamcom Research and Technology AB is a Swedish deep-tech house headquartered in Gothenburg that turns advanced technology into value across radar, wireless, optical, and AI systems. Their Test and Certification division provides end-to-end support throughout the testing and certification process, backed by in-house anechoic chamber facilities across three sites — Gothenburg (EMC, radio, radar, antenna, electronics, mechanics), Stockholm (electronics, optics), and Linköping (electronics, mechanics, 10 m RF and antenna measurement lab). The Gothenburg anechoic chamber is built for high-performance radio, EMC, antenna, and radar testing, with radiated emission coverage from 9 kHz to 40 GHz, conducted emission from 9 kHz to 30 MHz, spurious emission from 9 kHz to 90 GHz (extendable to 170 GHz), and radiated immunity from 80 MHz to 1 000 MHz and 1 to 67 GHz. ESD capability reaches 9 kV contact and 16.5 kV air discharge. Instrumentation includes an R&S FSW spectrum analyser (2 Hz–67 GHz, extendable to 170 GHz), Anritsu signal generator (DC to 70 GHz), network analysers to 90 GHz, and three environmental test chambers (down to −70 °C). Qamcom offers customised or standard test plans, chamber rental with on-site engineer support, complete CE marking packages, global market access (FCC, IC, UKCA, CB Scheme, VCCI, KC, etc.), PCB/EMC/RF/antenna simulation and design services, and EMC/RF troubleshooting.
Testing Services
| Test Type | Applicable Standards |
|---|---|
| Radiated Emissions | 9 kHz–40 GHz radiated emission, EN 55011, EN 55032, EN 55014-1/-2, FCC Part 15, ICES-003, RSS-Gen |
| Conducted Emissions | 9 kHz–30 MHz, EN 55011, EN 55032 |
| Radiated Immunity | EN/IEC 61000-4-3, 80 MHz–1 000 MHz and 1–67 GHz |
| Conducted Immunity | EN/IEC 61000-4-6, 150 kHz–80 MHz up to 10 Vrms |
| ESD | EN/IEC 61000-4-2, up to 9 kV contact, 16.5 kV air |
| EFT/Burst | EN/IEC 61000-4-4, up to 4 kV @ 5 kHz |
| Surge Immunity | EN/IEC 61000-4-5, up to 4 kV 1.2/50 µs |
| Harmonics & Flicker | EN/IEC 61000-3-2, EN/IEC 61000-3-3 |
| Voltage Dips/Interrupts | EN/IEC 61000-4-11, AC and DC ports |
| Power Frequency Magnetic Field | EN/IEC 61000-4-8, up to 10 A/m 50 Hz |
| Radio Equipment Testing | ETSI EN 301 489 series, FCC Part 15, WLAN, Bluetooth/BLE, P-t-P, SRD, Radar, Spurious emission 9 kHz–90 GHz (extendable to 170 GHz) |
| Pre-Compliance Testing | — |
| Environmental Testing | Thermotron S-32-8200-2-3: −70 to +180 °C, 10–98 % RH, 906 L, CTS C-40/200: −40 to +180 °C, 10–98 % RH, 200 L, Heraeus HT 7020: −70 to +180 °C, 106 L |
| Product Safety | CE LVD, CE RoHS, CE REACH, NEBS |
Certifications / Marks
| Certification |
|---|
| CE |
| FCC |
| ISED |
| UKCA |
| CB |
| VCCI |
| KCC |
Industries Served
| Industry |
|---|
| Aerospace & Defense |
| Automotive |
| Consumer Electronics |
| Industrial Equipment |
| Information Technology |
| Medical Devices |
| Military |
| Radio & Wireless |
| Telecommunications |
Major Equipment
| Equipment |
|---|
| Anechoic chamber (Gothenburg) — 9 kHz–40 GHz emission, 80 MHz–67 GHz immunity, 9 kHz–90 GHz spurious (extendable to 170 GHz) |
| 10 m RF and antenna measurement lab (Linköping) |
| R&S FSW spectrum analyser 2 Hz–67 GHz (extendable to 170 GHz) |
| Anritsu signal generator DC–70 GHz |
| Network analysers 5 Hz–90 GHz |
| Antennas 9 kHz–90 GHz |
| Thermotron S-32-8200-2-3 climate chamber (−70 to +180 °C, 906 L) |
| CTS C-40/200 climate chamber (−40 to +180 °C, 200 L) |
| Heraeus HT 7020 oven (−70 to +180 °C, 106 L) |
| R&S Elektra EMC software |
| Ansys HFSS, CST Studio, Comsol, Altium, Cadence, SolidWorks |