LKE Radiotechnika Marketing Sp. z o.o.
Katy Wroclawskie, Dolnoslaskie, Poland
+48 71 327 07 00ul. Fabryczna 20, Pietrzykowice, Katy Wroclawskie, Dolnoslaskie, 55-080, Poland
About
LKE Radiotechnika Marketing works from ul. Fabryczna at Pietrzykowice near Katy Wroclawskie, just outside Wroclaw, and holds two accreditations that together define what it is for: Polish Centre for Accreditation certificate AB 1732, and a Defence and Security accreditation under certificate 64/MON/2023 issued through the Polish Ministry of National Defence. That second credential is the one that matters - it lets the laboratory produce test evidence for Polish military procurement, and the military standards it works to are the Polish defence norm NO-06-A200 alongside MIL-STD-461. Its main semi-anechoic chamber is specified in full: 6 by 9 by 5.5 metres internally with a 2 by 2.5 metre door clearance, a 1.5-metre rotary table rated to 500 kilograms, ferrite and conical absorbers, configurable to meet ALSE requirements for automotive work, and fitted with fume exhaust and transit panels for liquid utilities and digital communication - the fume extraction and utility pass-throughs being what allow running engines, hydraulics and powered systems to be tested rather than just electronics. Measurement ranges are wide: conducted emissions from 9 kHz to 30 MHz, radiated emissions from 9 kHz to 26.5 GHz, electromagnetic field immunity from 10 kHz to 18 GHz, and frequency characteristics of subassemblies from 10 MHz to 20 GHz. Three specialist measurement lines set it apart from general compliance houses: shielding effectiveness of chambers and materials from 10 kHz to 18 GHz to IEEE Std 299 and PN-EN 50147-1, screening attenuation and transfer impedance of shielded harnesses and coaxial cables from 9 kHz to 3 GHz to IEC 62153-4-4, and attenuation and h-parameter measurement of EMI filters. Testing is also offered in situ at the equipment's installation site or the customer's premises. Specialisations are Polish military EMC to NO-06-A200 and MIL-STD-461, shielding effectiveness measurement, cable and harness screening attenuation, EMI filter characterisation, and chamber validation.
Accreditations
| Accreditation |
|---|
| ISO/IEC 17025 |
| EMC Directive 2014/30/EU |
Testing Services
| Test Type | Applicable Standards |
|---|---|
| Radiated Emissions | NO-06-A200, MIL-STD-461G RE102, MIL-STD-461G RE101, PN-EN 55013, PN-EN 55014-1, PN-EN 55011, PN-EN 55032, CISPR 25, PN-EN 55016-2-3 |
| Conducted Emissions | NO-06-A200, MIL-STD-461G CE101, MIL-STD-461G CE102, PN-EN 55013, PN-EN 55014-1, PN-EN 55011, PN-EN 55032, PN-EN 55016-2-1 |
| Radiated Immunity | NO-06-A200, MIL-STD-461G RS103, PN-EN 61000-4-3, PN-EN 55014-2, PN-EN 55035, ISO 11452-2 |
| Conducted Immunity | NO-06-A200, MIL-STD-461G CS114, PN-EN 61000-4-6, PN-EN 55014-2, PN-EN 55035 |
| Radiated Susceptibility | NO-06-A200, MIL-STD-461G RS101, MIL-STD-461G RS103, MIL-STD-461G RS105 |
| Conducted Susceptibility | NO-06-A200, MIL-STD-461G CS101, MIL-STD-461G CS114, MIL-STD-461G CS115, MIL-STD-461G CS116, ISO 7637-2 |
| ESD | PN-EN 61000-4-2, IEC 61000-4-2, ISO 10605 |
| EFT/Burst | PN-EN 61000-4-4, IEC 61000-4-4 |
| Surge Immunity | PN-EN 61000-4-5, IEC 61000-4-5 |
| Harmonics & Flicker | PN-EN 61000-3-2, PN-EN 61000-3-3 |
| Voltage Dips/Interrupts | PN-EN 61000-4-11, IEC 61000-4-11 |
| Power Frequency Magnetic Field | PN-EN 61000-4-8, MIL-STD-461G RS101 |
| Bulk Current Injection (BCI) | ISO 11452-4, MIL-STD-461G CS114 |
| Pre-Compliance Testing | NO-06-A200, MIL-STD-461G, PN-EN 55032, CISPR 25 |
| Military EMC | NO-06-A200, MIL-STD-461E, MIL-STD-461F, MIL-STD-461G |
| MIL-STD-461 | MIL-STD-461E, MIL-STD-461F, MIL-STD-461G |
| Automotive Component EMC | CISPR 25, ISO 11452-2, ISO 11452-4, ISO 7637-2, UN-ECE R10 |
| Environmental Testing | IEEE Std 299, PN-EN 50147-1, IEC 62153-4-4, IEC 61000-5-7 |
| Product Safety | IEEE Std 299, PN-EN 50147-1, IEC 62153-4-4 |
Certifications / Marks
| Certification |
|---|
| CE |
| PCA AB 1732 accredited test reports |
| Polish MoD Defence and Security accreditation 64/MON/2023 |
| UN-ECE E-mark support |
Industries Served
| Industry |
|---|
| Military |
| Aerospace & Defense |
| Automotive |
| Industrial Equipment |
| Telecommunications |
| Consumer Electronics |
| Multimedia |
| Railway |
Major Equipment
| Equipment |
|---|
| Semi-anechoic chamber 6 x 9 x 5.5 m internal, door clearance 2 x 2.5 m |
| Rotary table 1.5 m diameter, 500 kg load capacity |
| Ferrite and conical absorbers, configurable to ALSE requirements |
| Chamber fume exhaust system |
| Transit and connection panels for liquid utilities and digital communication |
| Conducted emissions 9 kHz - 30 MHz |
| Radiated emissions 9 kHz - 26.5 GHz |
| Electromagnetic field immunity 10 kHz - 18 GHz |
| Shielding effectiveness measurement 10 kHz - 18 GHz (chambers and materials) |
| Screening attenuation and transfer impedance 9 kHz - 3 GHz (harnesses, coaxial cables) |
| Frequency characteristic measurement 10 MHz - 20 GHz |
| Coaxial cable attenuation measurement, 50 ohm and 75 ohm |
| EMI filter attenuation and h-parameter measurement bench |
| EMI receiver |
| Spectrum analyser |
| LISN |
| CDN |
| BCI injection probes |
| ESD simulator |
| EFT/burst generator |
| Surge generator |
| High-power RF amplifiers and immunity antennas |
| Portable instrumentation for in situ testing |