SIQ Ljubljana - Slovenian Institute of Quality and Metrology
Ljubljana, Ljubljana, Slovenia
+386 1 4778 105Masera-Spasiceva ulica 10, Ljubljana, Ljubljana, SI-1000, Slovenia
About
SIQ, the Slovenian Institute of Quality and Metrology, works from Masera-Spasiceva ulica in Ljubljana as an independent, impartial not-for-profit institution. Its testing and measurement work goes back to 1964, in the Sector for Measurements and Quality of the Institute for Automation, and SIQ itself was founded at the end of 1992 as successor to the Institute of Quality and Metrology, under a contract signed by the Government of Slovenia, the Chamber of Commerce and Industry, Iskra Holding, Gorenje, Triglav Insurance and IKM; it holds Slovenia's national measurement standards for electric quantities and for time and frequency. Its Safety and Electromagnetics unit is accredited by Slovenian Accreditation to SIST EN ISO/IEC 17025 under number LP-009, is a recognised CB Testing Laboratory in the IECEE system, is EU Notified Body number 1304 for both the EMC Directive 2014/30/EU and the Radio Equipment Directive, is recognised by ISED Canada as a Wireless Device Testing Laboratory under company number 21434, and is accredited for FCC rules 15.225, 15.247, 15.249 and 15.407. It issues UN-ECE R10 approvals under three E-marks - E25, E26 and E57. The facility list is a semi-anechoic chamber at 3 metres, a 10-metre open area test site, a reverberation chamber used for ISO 11452-11 across 200 MHz to 6 GHz, and an absorber-lined shielded enclosure for ISO 11452-2. Published limits are specific: radiated emissions from 9 kHz to 40 GHz; radiated immunity to 6 GHz at 30 V/m and to 600 V/m for ISO 11452-2; ESD at 20 kV contact and 30 kV air; burst at 5.5 kV and surge at 5 kV, both to 63 A per phase; AC supply to four times 400 A per phase through an artificial mains network at 400 V phase-to-ground and 700 V phase-to-phase; DC to 400 A per line at 1,000 V; and magnetic fields of 100 A/m continuous and 1,000 A/m short duration. The immunity scope is among the most current anywhere in this directory, including IEC 61000-4-41 for 4G and 5G broadband immunity, -4-39 proximity fields, -4-19 differential mode, and -4-12, -4-16, -4-18, -4-29 and -4-34, with IEC TS 60601-4-2:2024 for medical devices, EN 50592 for railways, EN 61851-21-2 for EV charging and ANSI C63.27-2021 for wireless coexistence. Automotive work runs to the OEM methods of Volkswagen, BMW, Daimler, Volvo and Renault-Nissan. Specialisations are high-current and high-voltage EMC, medical 4G and 5G broadband immunity, automotive OEM methods, wireless coexistence, EMF exposure measurement from 0 Hz to 18 GHz, shielding efficiency measurement and on-site testing.
Accreditations
| Accreditation |
|---|
| ISO/IEC 17025 |
| IECEE CB Scheme |
| EMC Directive 2014/30/EU |
| Radio Equipment Directive (RED) 2014/53/EU |
| ISED (Canada) |
| FCC Listed |
Testing Services
| Test Type | Applicable Standards |
|---|---|
| Radiated Emissions | EN 55011, CISPR 11, EN 55014-1, CISPR 14-1, EN 55015, CISPR 15, EN 55032, CISPR 32, CISPR 16-2-3, CFR 47 Part 15B, ICES-003, EN 61000-6-3, EN 61000-6-4, EN 61000-6-8, CISPR 25, EN 50121-3-2, UN-ECE R10 |
| Conducted Emissions | EN 55011, CISPR 11, EN 55014-1, CISPR 14-1, EN 55015, CISPR 15, EN 55032, CISPR 32, CISPR 16-2-1, CISPR 16-2-2, CFR 47 Part 15B, ICES-003, EN 61000-6-3, EN 61000-6-4, EN 61000-6-8, CISPR 25 |
| Radiated Immunity | EN 61000-4-3, IEC 61000-4-3, EN 61000-4-39, EN 61000-4-41, EN 55035, EN 55014-2, EN 61547-1, EN 61000-6-1, EN 61000-6-2, EN 61000-6-7, EN 60601-1-2, IEC TS 60601-4-2:2024, EN 61326-1, ISO 11452-2, ISO 11452-11, EN 50121-4, EN 61851-21-2 |
| Conducted Immunity | EN 61000-4-6, IEC 61000-4-6, EN 61000-4-16, EN 61000-4-19, EN 55035, EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 60601-1-2, EN 61326-1, ISO 11452-4, EN 50121-4 |
| Radiated Susceptibility | ISO 11452-2, ISO 11452-11, EN 61000-4-3, EN 61000-4-39 |
| Conducted Susceptibility | ISO 7637-2, ISO 7637-3, ISO 11452-4, ISO 16750-2, EN 61000-4-16, EN 61000-4-19, EN 61000-4-29 |
| ESD | EN 61000-4-2, IEC 61000-4-2, ISO 10605, EN 60601-1-2 |
| EFT/Burst | EN 61000-4-4, IEC 61000-4-4, EN 60601-1-2 |
| Surge Immunity | EN 61000-4-5, IEC 61000-4-5, EN 61000-4-12, EN 61000-4-18, EN 60601-1-2 |
| Harmonics & Flicker | EN 61000-3-2, EN 61000-3-3, EN 61000-3-11, EN 61000-3-12, EN 61000-4-7 |
| Voltage Dips/Interrupts | EN 61000-4-11, EN 61000-4-29, EN 61000-4-34, EN 60601-1-2 |
| Power Frequency Magnetic Field | EN 61000-4-8, EN 61000-4-9, EN 61000-4-39, EN 60601-1-2 |
| Bulk Current Injection (BCI) | ISO 11452-4 |
| Wireless Coexistence | ANSI C63.27-2021 |
| Pre-Compliance Testing | CISPR 32, CISPR 11, EN 61000-4-3, CISPR 25, EN 61000-6-2 |
| Radio Equipment Testing | ETSI EN 300 220-2, ETSI EN 300 330, ETSI EN 300 328, ETSI EN 301 893, ETSI EN 300 440, FCC Part 15.225, FCC Part 15.247, FCC Part 15.249, FCC Part 15.407, RSS-Gen, RSS-210, RSS-247 |
| RFID Assessment | ETSI EN 300 330, FCC Part 15.225, ETSI EN 302 208 |
| SAR Testing | EN IEC 62311, EN 62479, EN 62233, FCC 1.1307, FCC 1.1310, FCC 2.1091, FCC 2.1093, FCC KDB 447498, FCC KDB 680106, RSS-102, AS/NZS 2772-2 |
| Medical Device EMC | EN 60601-1-2, IEC TS 60601-4-2:2024, EN 61000-4-39, EN 61000-4-41, EN 61326-1 |
| Automotive Component EMC | CISPR 25, ISO 11452-2, ISO 11452-4, ISO 11452-11, ISO 7637-2, ISO 7637-3, ISO 10605, ISO 16750-2, UN-ECE R10 |
| Automotive Vehicle-Level EMC | UN-ECE R10, CISPR 12, ISO 11451-2 |
| Automotive OEM Specifications | Volkswagen EMC specifications, BMW EMC specifications, Daimler EMC specifications, Volvo EMC specifications, Renault-Nissan EMC specifications, CISPR 25, ISO 11452 series |
| Railway EMC | EN 50121-1, EN 50121-2, EN 50121-3-1, EN 50121-3-2, EN 50121-4, EN 50121-5, EN 50592 |
| Environmental Testing | EN 60730-1, IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-30, IEC 60068-2-78 |
| Product Safety | EN 60335-1, EN 62841-1, EN 62368-1, EN 61010-1, EN 60598-1, EN 60601-1, EN 60730-1, EN 61851-21-2, SANS specifications |
Certifications / Marks
| Certification |
|---|
| CE |
| Notified Body 1304 certificates |
| EU type examination certificate |
| FCC |
| FCC SDoC |
| ISED |
| IECEE CB Certificate |
| VCCI registration reports |
| KS C (Korea) |
| SABS / SANS (South Africa) |
| UN-ECE E-mark (E25, E26, E57) |
Industries Served
| Industry |
|---|
| Household Appliances |
| Information Technology |
| Multimedia |
| Industrial Equipment |
| Medical Devices |
| Lighting Products |
| Railway |
| Automotive |
| Energy & Power |
| Telecommunications |
| Radio & Wireless |
| Consumer Electronics |
Major Equipment
| Equipment |
|---|
| Semi-anechoic chamber (SAC), 3 m test distance |
| Open area test site (OATS), 10 m test distance |
| Reverberation chamber for ISO 11452-11, 200 MHz - 6 GHz |
| Absorber-lined shielded enclosure for ISO 11452-2 |
| Radiated emissions measurement 9 kHz - 40 GHz |
| Radiated immunity to 6 GHz: 30 V/m (80 MHz - 6 GHz), 600 V/m for ISO 11452-2 |
| ESD simulator: 20 kV contact, 30 kV air |
| EFT/burst generator: 5.5 kV, to 63 A per phase |
| Surge generator: 5 kV, to 63 A per phase |
| AC supply to 4 x 400 A per phase with AMN, 400 V phase-to-ground, 700 V phase-to-phase |
| DC supply to 400 A per line with AN, 1,000 V DC |
| Magnetic field coils: 100 A/m continuous, 1,000 A/m short duration |
| EMF / MPE exposure measurement 0 Hz - 18 GHz |
| Electromagnetic shielding efficiency measurement apparatus |
| Harmonics, flicker and network impedance measurement |
| EMI receiver |
| Spectrum analyser |
| LISN / AMN |
| CDN |
| BCI injection probes |
| Automotive transient generator (ISO 7637-2 / -3) |
| RF power amplifiers and immunity antennas |
| Portable instrumentation for on-site EMC testing (including UPS systems) |
| EMC test equipment calibration laboratory |
| Slovenian national measurement standards for electric quantities, time and frequency |