EMC Latest
← Back to Labs Directory
SIQ Ljubljana - Slovenian Institute of Quality and Metrology

SIQ Ljubljana - Slovenian Institute of Quality and Metrology

Ljubljana, Ljubljana, Slovenia

+386 1 4778 105

Masera-Spasiceva ulica 10, Ljubljana, Ljubljana, SI-1000, Slovenia

1 / 5

About

SIQ, the Slovenian Institute of Quality and Metrology, works from Masera-Spasiceva ulica in Ljubljana as an independent, impartial not-for-profit institution. Its testing and measurement work goes back to 1964, in the Sector for Measurements and Quality of the Institute for Automation, and SIQ itself was founded at the end of 1992 as successor to the Institute of Quality and Metrology, under a contract signed by the Government of Slovenia, the Chamber of Commerce and Industry, Iskra Holding, Gorenje, Triglav Insurance and IKM; it holds Slovenia's national measurement standards for electric quantities and for time and frequency. Its Safety and Electromagnetics unit is accredited by Slovenian Accreditation to SIST EN ISO/IEC 17025 under number LP-009, is a recognised CB Testing Laboratory in the IECEE system, is EU Notified Body number 1304 for both the EMC Directive 2014/30/EU and the Radio Equipment Directive, is recognised by ISED Canada as a Wireless Device Testing Laboratory under company number 21434, and is accredited for FCC rules 15.225, 15.247, 15.249 and 15.407. It issues UN-ECE R10 approvals under three E-marks - E25, E26 and E57. The facility list is a semi-anechoic chamber at 3 metres, a 10-metre open area test site, a reverberation chamber used for ISO 11452-11 across 200 MHz to 6 GHz, and an absorber-lined shielded enclosure for ISO 11452-2. Published limits are specific: radiated emissions from 9 kHz to 40 GHz; radiated immunity to 6 GHz at 30 V/m and to 600 V/m for ISO 11452-2; ESD at 20 kV contact and 30 kV air; burst at 5.5 kV and surge at 5 kV, both to 63 A per phase; AC supply to four times 400 A per phase through an artificial mains network at 400 V phase-to-ground and 700 V phase-to-phase; DC to 400 A per line at 1,000 V; and magnetic fields of 100 A/m continuous and 1,000 A/m short duration. The immunity scope is among the most current anywhere in this directory, including IEC 61000-4-41 for 4G and 5G broadband immunity, -4-39 proximity fields, -4-19 differential mode, and -4-12, -4-16, -4-18, -4-29 and -4-34, with IEC TS 60601-4-2:2024 for medical devices, EN 50592 for railways, EN 61851-21-2 for EV charging and ANSI C63.27-2021 for wireless coexistence. Automotive work runs to the OEM methods of Volkswagen, BMW, Daimler, Volvo and Renault-Nissan. Specialisations are high-current and high-voltage EMC, medical 4G and 5G broadband immunity, automotive OEM methods, wireless coexistence, EMF exposure measurement from 0 Hz to 18 GHz, shielding efficiency measurement and on-site testing.

Accreditations

Accreditation
ISO/IEC 17025
IECEE CB Scheme
EMC Directive 2014/30/EU
Radio Equipment Directive (RED) 2014/53/EU
ISED (Canada)
FCC Listed

Testing Services

Test TypeApplicable Standards
Radiated EmissionsEN 55011, CISPR 11, EN 55014-1, CISPR 14-1, EN 55015, CISPR 15, EN 55032, CISPR 32, CISPR 16-2-3, CFR 47 Part 15B, ICES-003, EN 61000-6-3, EN 61000-6-4, EN 61000-6-8, CISPR 25, EN 50121-3-2, UN-ECE R10
Conducted EmissionsEN 55011, CISPR 11, EN 55014-1, CISPR 14-1, EN 55015, CISPR 15, EN 55032, CISPR 32, CISPR 16-2-1, CISPR 16-2-2, CFR 47 Part 15B, ICES-003, EN 61000-6-3, EN 61000-6-4, EN 61000-6-8, CISPR 25
Radiated ImmunityEN 61000-4-3, IEC 61000-4-3, EN 61000-4-39, EN 61000-4-41, EN 55035, EN 55014-2, EN 61547-1, EN 61000-6-1, EN 61000-6-2, EN 61000-6-7, EN 60601-1-2, IEC TS 60601-4-2:2024, EN 61326-1, ISO 11452-2, ISO 11452-11, EN 50121-4, EN 61851-21-2
Conducted ImmunityEN 61000-4-6, IEC 61000-4-6, EN 61000-4-16, EN 61000-4-19, EN 55035, EN 55014-2, EN 61000-6-1, EN 61000-6-2, EN 60601-1-2, EN 61326-1, ISO 11452-4, EN 50121-4
Radiated SusceptibilityISO 11452-2, ISO 11452-11, EN 61000-4-3, EN 61000-4-39
Conducted SusceptibilityISO 7637-2, ISO 7637-3, ISO 11452-4, ISO 16750-2, EN 61000-4-16, EN 61000-4-19, EN 61000-4-29
ESDEN 61000-4-2, IEC 61000-4-2, ISO 10605, EN 60601-1-2
EFT/BurstEN 61000-4-4, IEC 61000-4-4, EN 60601-1-2
Surge ImmunityEN 61000-4-5, IEC 61000-4-5, EN 61000-4-12, EN 61000-4-18, EN 60601-1-2
Harmonics & FlickerEN 61000-3-2, EN 61000-3-3, EN 61000-3-11, EN 61000-3-12, EN 61000-4-7
Voltage Dips/InterruptsEN 61000-4-11, EN 61000-4-29, EN 61000-4-34, EN 60601-1-2
Power Frequency Magnetic FieldEN 61000-4-8, EN 61000-4-9, EN 61000-4-39, EN 60601-1-2
Bulk Current Injection (BCI)ISO 11452-4
Wireless CoexistenceANSI C63.27-2021
Pre-Compliance TestingCISPR 32, CISPR 11, EN 61000-4-3, CISPR 25, EN 61000-6-2
Radio Equipment TestingETSI EN 300 220-2, ETSI EN 300 330, ETSI EN 300 328, ETSI EN 301 893, ETSI EN 300 440, FCC Part 15.225, FCC Part 15.247, FCC Part 15.249, FCC Part 15.407, RSS-Gen, RSS-210, RSS-247
RFID AssessmentETSI EN 300 330, FCC Part 15.225, ETSI EN 302 208
SAR TestingEN IEC 62311, EN 62479, EN 62233, FCC 1.1307, FCC 1.1310, FCC 2.1091, FCC 2.1093, FCC KDB 447498, FCC KDB 680106, RSS-102, AS/NZS 2772-2
Medical Device EMCEN 60601-1-2, IEC TS 60601-4-2:2024, EN 61000-4-39, EN 61000-4-41, EN 61326-1
Automotive Component EMCCISPR 25, ISO 11452-2, ISO 11452-4, ISO 11452-11, ISO 7637-2, ISO 7637-3, ISO 10605, ISO 16750-2, UN-ECE R10
Automotive Vehicle-Level EMCUN-ECE R10, CISPR 12, ISO 11451-2
Automotive OEM SpecificationsVolkswagen EMC specifications, BMW EMC specifications, Daimler EMC specifications, Volvo EMC specifications, Renault-Nissan EMC specifications, CISPR 25, ISO 11452 series
Railway EMCEN 50121-1, EN 50121-2, EN 50121-3-1, EN 50121-3-2, EN 50121-4, EN 50121-5, EN 50592
Environmental TestingEN 60730-1, IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-30, IEC 60068-2-78
Product SafetyEN 60335-1, EN 62841-1, EN 62368-1, EN 61010-1, EN 60598-1, EN 60601-1, EN 60730-1, EN 61851-21-2, SANS specifications

Certifications / Marks

Certification
CE
Notified Body 1304 certificates
EU type examination certificate
FCC
FCC SDoC
ISED
IECEE CB Certificate
VCCI registration reports
KS C (Korea)
SABS / SANS (South Africa)
UN-ECE E-mark (E25, E26, E57)

Industries Served

Industry
Household Appliances
Information Technology
Multimedia
Industrial Equipment
Medical Devices
Lighting Products
Railway
Automotive
Energy & Power
Telecommunications
Radio & Wireless
Consumer Electronics

Major Equipment

Equipment
Semi-anechoic chamber (SAC), 3 m test distance
Open area test site (OATS), 10 m test distance
Reverberation chamber for ISO 11452-11, 200 MHz - 6 GHz
Absorber-lined shielded enclosure for ISO 11452-2
Radiated emissions measurement 9 kHz - 40 GHz
Radiated immunity to 6 GHz: 30 V/m (80 MHz - 6 GHz), 600 V/m for ISO 11452-2
ESD simulator: 20 kV contact, 30 kV air
EFT/burst generator: 5.5 kV, to 63 A per phase
Surge generator: 5 kV, to 63 A per phase
AC supply to 4 x 400 A per phase with AMN, 400 V phase-to-ground, 700 V phase-to-phase
DC supply to 400 A per line with AN, 1,000 V DC
Magnetic field coils: 100 A/m continuous, 1,000 A/m short duration
EMF / MPE exposure measurement 0 Hz - 18 GHz
Electromagnetic shielding efficiency measurement apparatus
Harmonics, flicker and network impedance measurement
EMI receiver
Spectrum analyser
LISN / AMN
CDN
BCI injection probes
Automotive transient generator (ISO 7637-2 / -3)
RF power amplifiers and immunity antennas
Portable instrumentation for on-site EMC testing (including UPS systems)
EMC test equipment calibration laboratory
Slovenian national measurement standards for electric quantities, time and frequency