SIRIM QAS International Sdn. Bhd.
Shah Alam, Selangor, Malaysia
+60 3-5544 6400SIRIM Complex, No. 1 Persiaran Dato' Menteri, Section 2, P.O. Box 7035, Shah Alam, Selangor, 40700, Malaysia
About
SIRIM QAS International is the testing and certification arm of SIRIM Berhad, Malaysia's national standards and industrial research organisation, and operates from the SIRIM Complex on Persiaran Dato' Menteri in Section 2 of Shah Alam, Selangor, west of Kuala Lumpur. It is the dominant route to Malaysian market access for electrical, electronic and communications products: SIRIM QAS performs the conformity assessment behind the SIRIM label that communications and multimedia equipment must carry for the Malaysian Communications and Multimedia Commission, and runs product certification, inspection and import permit work alongside the testing. Its EMC capability is built on two anechoic chambers with a 3-metre antenna-to-equipment distance plus a genuine open area test site - the OATS is separately identified on the complex and remains the reference method against which chamber site attenuation is validated, so borderline chamber results can be resolved rather than merely repeated. The laboratory is accredited to ISO/IEC 17025 and operates as a notified laboratory, with ISO 9001 certification; its Penang laboratory was reported in 2026 to have achieved A2LA accreditation, extending United States acceptance. Shielding effectiveness testing is offered as a distinct service, which few general laboratories provide. The accredited standards reach well past the commercial directive set: alongside CISPR 11, 32 and 35, the IEC 61000-3 and 61000-4 series and FCC Part 15, it covers the automotive ISO 11452 series including parts 1, 4, 7, 8 and 10, ISO 7637 parts 1 to 3 and ISO 10605, plus MIL-STD-461 for military equipment and RTCA DO-160 for airborne equipment - an unusually broad span for a single national body. Radio frequency testing sits beside the EMC work. Industries served are automotive, household appliances, industrial equipment, laboratory equipment and medical devices. Note that SIRIM's own pages block automated retrieval, so this record is built from its indexed service pages, directory profiles and public listings; the complex publishes both 40000 and 40700 Shah Alam postcodes, the latter being the PO Box. Specialisations are Malaysian SIRIM label and MCMC certification, open area test site measurement, shielding effectiveness testing, and automotive, military and airborne EMC.
Accreditations
| Accreditation |
|---|
| ISO/IEC 17025 |
| IECEE CB Scheme |
| FCC Listed |
| APEC MRA |
Testing Services
| Test Type | Applicable Standards |
|---|---|
| Radiated Emissions | CISPR 11, CISPR 32, CISPR 14-1, CISPR 15, CISPR 25, EN 55011, EN 55032, EN 55022, FCC Part 15B, FCC Part 15C, ANSI C63.4, MS CISPR 32, MIL-STD-461G RE102, RTCA DO-160G Section 21 |
| Conducted Emissions | CISPR 11, CISPR 32, CISPR 14-1, CISPR 15, CISPR 25, EN 55011, EN 55032, EN 55022, FCC Part 15B, ANSI C63.4, MIL-STD-461G CE101, MIL-STD-461G CE102, RTCA DO-160G Section 21 |
| Radiated Immunity | IEC 61000-4-3, EN 61000-4-3, CISPR 35, CISPR 24, IEC 61000-6-1, IEC 61000-6-2, ISO 11452-2, MIL-STD-461G RS103, RTCA DO-160G Section 20 |
| Conducted Immunity | IEC 61000-4-6, EN 61000-4-6, CISPR 35, CISPR 24, IEC 61000-6-1, IEC 61000-6-2, ISO 11452-4, MIL-STD-461G CS114 |
| Radiated Susceptibility | MIL-STD-461G RS101, MIL-STD-461G RS103, ISO 11452-2, RTCA DO-160G Section 20 |
| Conducted Susceptibility | MIL-STD-461G CS101, MIL-STD-461G CS114, MIL-STD-461G CS116, ISO 7637-1, ISO 7637-2, ISO 7637-3, ISO 11452-4 |
| ESD | IEC 61000-4-2, EN 61000-4-2, ISO 10605 |
| EFT/Burst | IEC 61000-4-4, EN 61000-4-4 |
| Surge Immunity | IEC 61000-4-5, EN 61000-4-5 |
| Harmonics & Flicker | IEC 61000-3-2, EN 61000-3-2, IEC 61000-3-3, EN 61000-3-3 |
| Voltage Dips/Interrupts | IEC 61000-4-11, EN 61000-4-11 |
| Power Frequency Magnetic Field | IEC 61000-4-8, EN 61000-4-8, ISO 11452-8 |
| Bulk Current Injection (BCI) | ISO 11452-4, MIL-STD-461G CS114 |
| Pre-Compliance Testing | CISPR 32, CISPR 11, IEC 61000-4-3, FCC Part 15B, ISO 11452-2 |
| Radio Equipment Testing | FCC Part 15.247, FCC Part 15.407, ETSI EN 300 328, ETSI EN 301 489-1, ETSI EN 301 489-17, MCMC technical specifications, ANSI C63.10 |
| Automotive Component EMC | ISO 11452-1, ISO 11452-4, ISO 11452-7, ISO 11452-8, ISO 11452-10, ISO 7637-1, ISO 7637-2, ISO 7637-3, ISO 10605, CISPR 25 |
| Military EMC | MIL-STD-461F, MIL-STD-461G |
| MIL-STD-461 | MIL-STD-461F, MIL-STD-461G |
| Commercial Aviation EMC | RTCA DO-160G Section 20, RTCA DO-160G Section 21 |
| Medical Device EMC | IEC 60601-1-2, IEC 61326-1 |
| Environmental Testing | IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-30, IEC 60068-2-78, IEC 60529 |
| Product Safety | IEC 60335-1, MS IEC 60335-1, IEC 62368-1, IEC 61010-1, IEC 60598-1, IEC 60601-1 |
Certifications / Marks
| Certification |
|---|
| SIRIM label (MCMC certification) |
| SIRIM product certification mark |
| CE |
| FCC |
| IECEE CB Certificate |
| ISO 9001 |
| Malaysian import permit support |
Industries Served
| Industry |
|---|
| Automotive |
| Household Appliances |
| Industrial Equipment |
| Medical Devices |
| Consumer Electronics |
| Telecommunications |
| Radio & Wireless |
| Information Technology |
| Military |
| Aerospace & Defense |
Major Equipment
| Equipment |
|---|
| Two anechoic chambers, 3 m antenna-to-EUT distance |
| Open area test site (OATS) on the SIRIM Complex |
| Shielding effectiveness test apparatus |
| EMI receiver |
| Spectrum analyser |
| LISN |
| CDN |
| BCI injection probes |
| ESD simulator |
| EFT/burst generator |
| Surge generator |
| Harmonics and flicker analyser |
| Power frequency magnetic field coil |
| Automotive transient generator (ISO 7637-1 / -2 / -3) |
| RF power amplifiers and immunity antennas |
| Radio frequency test equipment |
| Environmental test chambers |
| Calibration and measurement laboratory |
| Penang laboratory (reported A2LA accreditation, 2026) |