Thales ECC - Environmental Competence Center, Hengelo
Hengelo, Overijssel, Netherlands
+31 74 248 3219Robijnstraat 12, Hengelo, Overijssel, 7554 TB, Netherlands
About
Thales ECC is the Environmental Competence Center of Thales Nederland B.V., on Robijnstraat within the Thales campus at Hengelo in Overijssel, and it is the test house behind the naval radar and combat system business that Thales Nederland is built on - a heritage that explains both the scale of the equipment it handles and the severity of the environments it reproduces. It offers its capacity commercially, and its own description of its range is memorable: it tests products from radars to art objects. Five disciplines sit on the site. Climatic testing covers heat, cold, humidity and dust and desert conditions, with temperatures to plus 50 degrees Celsius cited. Mechanical testing uses an electrodynamic shaker for vibration and shock work, recently joined by a new high-power shaker. Electromagnetic compatibility testing sits alongside, as does ingress protection testing for water and dust, and surface treatment and corrosion testing including salt spray and filiform corrosion - the last being the creeping thread-like corrosion under paint and coatings that matters for equipment in marine service. Pre-test consultancy and training courses are offered as part of the service rather than as extras, which suits customers bringing complex or one-off articles that need a test plan written before anything is switched on. The combination of EMC with climatic, vibration, ingress and corrosion testing under one roof is the practical draw: a naval or defence electronics qualification programme normally has to be split across several laboratories. The site links to an ISO/IEC 17025 section but publishes no accreditation body, number or scope, and it names no EMC standards, chamber dimensions, frequency ranges or field strengths, so it is recorded here without an accreditation entry and the accredited scope should be confirmed directly. Specialisations are combined environmental, mechanical and EMC qualification, large and unusual test articles, marine and defence electronics environments, and corrosion testing.
Testing Services
| Test Type | Applicable Standards |
|---|---|
| Radiated Emissions | MIL-STD-461G RE102, MIL-STD-461G RE101, EN 55011, CISPR 11, EN 60945, EN 61000-6-4, STANAG 4370 / AECTP-500 |
| Conducted Emissions | MIL-STD-461G CE101, MIL-STD-461G CE102, EN 55011, CISPR 11, EN 60945, EN 61000-6-4 |
| Radiated Immunity | MIL-STD-461G RS103, IEC 61000-4-3, EN 61000-6-2, EN 60945, AECTP-500 |
| Conducted Immunity | MIL-STD-461G CS114, IEC 61000-4-6, EN 61000-6-2, EN 60945 |
| Radiated Susceptibility | MIL-STD-461G RS101, MIL-STD-461G RS103, MIL-STD-461G RS105, AECTP-500 |
| Conducted Susceptibility | MIL-STD-461G CS101, MIL-STD-461G CS114, MIL-STD-461G CS115, MIL-STD-461G CS116 |
| ESD | IEC 61000-4-2, MIL-STD-461G CS118 |
| EFT/Burst | IEC 61000-4-4 |
| Surge Immunity | IEC 61000-4-5 |
| Pre-Compliance Testing | MIL-STD-461G, IEC 61000-4-3, EN 60945 |
| Military EMC | MIL-STD-461F, MIL-STD-461G, MIL-STD-464, STANAG 4370, AECTP-500 |
| MIL-STD-461 | MIL-STD-461F, MIL-STD-461G |
| Environmental Testing | IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-11, IEC 60068-2-30, IEC 60068-2-52, IEC 60068-2-68, IEC 60068-2-78, IEC 60529, MIL-STD-810H, AECTP-300, ISO 9227, ASTM D2803 |
| Mechanical Testing | IEC 60068-2-6, IEC 60068-2-27, IEC 60068-2-64, MIL-STD-810H Method 514, MIL-STD-810H Method 516, AECTP-400 |
| Product Safety | IEC 60529, EN 60945, IEC 62368-1 |
Certifications / Marks
| Certification |
|---|
| Thales ECC test reports |
| CE |
| Naval and defence qualification test evidence |
Industries Served
| Industry |
|---|
| Aerospace & Defense |
| Military |
| Industrial Equipment |
| Telecommunications |
| Radio & Wireless |
| Energy & Power |
Major Equipment
| Equipment |
|---|
| EMC test facility (chamber dimensions and frequency ranges not published) |
| Electrodynamic shaker for vibration and shock testing |
| New high-power shaker |
| Climatic chambers: heat, cold, humidity, dust and desert conditions (to +50 C cited) |
| IP ingress protection test rigs (water and dust) |
| Salt spray corrosion chamber |
| Filiform corrosion test facility |
| Surface treatment evaluation laboratory |
| EMI receiver |
| Spectrum analyser |
| LISN |
| CDN |
| ESD simulator |
| EFT/burst generator |
| Surge generator |
| RF power amplifiers and immunity antennas |
| Pre-test consultancy and training facilities |
| Capacity for large test articles up to radar-scale assemblies |