EMC Latest
← Back to Labs Directory
WiRan Sp. z o.o. - ELAB

WiRan Sp. z o.o. - ELAB

Gdynia, Pomorskie, Poland

+48 58 663 10 10

Aleja Zwyciestwa 96/98, Gdynia, Pomorskie, 81-451, Poland

About

WiRan - the name expands to Wireless Range Systems - has worked as a hardware design office since 2002 and operates its ELAB test laboratory at the Pomeranian Science and Technology Park on Aleja Zwyciestwa in Gdynia, on the Baltic coast north of Gdansk. It is a design house with a laboratory attached rather than a pure test house, and that shapes the offer: EMC testing and pre-certification sit alongside EMC troubleshooting with design feedback, radio frequency and antenna design, wireless device radio parameter measurement and hardware design, so a failing product can be diagnosed and redesigned by the same engineers who measured it. The facility centres on a Faraday cage that WiRan describes as one of the largest in the region, paired with a climatic chamber running from minus 40 to plus 180 degrees Celsius at 10 to 98 per cent relative humidity with a temperature change rate of 6 degrees per minute. Customers confirm an anechoic chamber and climatic chamber on site. The standards it works to span both commercial and military ground: IEC 61000-4-2 through -4-8 for immunity, PN-EN 55022 for conducted and radiated emissions, and - more unusually - the Polish defence norm NO-06-A500 together with MIL-STD-461G, covering conducted emissions from 150 kHz to 30 MHz, radiated emissions from 100 MHz to 12 GHz and immunity from 1 to 6 GHz. Climatic testing runs to PN-EN 60068-2-1, -2-2, -2-14, -2-30 and -2-78 plus the defence norms NO-06-A103 and NO-06-A107. RF spectrum testing under the Radio Equipment Directive is available through ELAB rental, and the laboratory also prepares clients for accredited certification elsewhere. WiRan is noted as an ESA partner, and its named clients include INVOLI, SOLARIS and PESA Bydgoszcz. It publishes no PCA accreditation number, so it is recorded here without an accreditation entry and should be read as a pre-compliance and development laboratory. Specialisations are EMC pre-certification with design feedback, Polish and NATO defence norms, RF and antenna design, space and maritime applications, and combined EMC with climatic testing.

Testing Services

Test TypeApplicable Standards
Radiated EmissionsPN-EN 55022, NO-06-A500, MIL-STD-461G RE102, CISPR 32, CISPR 11
Conducted EmissionsPN-EN 55022, NO-06-A500, MIL-STD-461G CE102, CISPR 32, CISPR 11
Radiated ImmunityIEC 61000-4-3, NO-06-A500, MIL-STD-461G RS103, PN-EN 55024
Conducted ImmunityIEC 61000-4-6, NO-06-A500, MIL-STD-461G CS114, PN-EN 55024
Radiated SusceptibilityMIL-STD-461G RS103, NO-06-A500, IEC 61000-4-3
ESDIEC 61000-4-2, PN-EN 61000-4-2
EFT/BurstIEC 61000-4-4, PN-EN 61000-4-4
Surge ImmunityIEC 61000-4-5, PN-EN 61000-4-5
Power Frequency Magnetic FieldIEC 61000-4-8, PN-EN 61000-4-8
Pre-Compliance TestingPN-EN 55022, IEC 61000-4-3, MIL-STD-461G, NO-06-A500, Directive 2014/30/EU
Radio Equipment TestingDirective 2014/53/EU (RED), ETSI EN 300 328, ETSI EN 301 489-1, ETSI EN 301 489-17, ETSI EN 300 220
Military EMCNO-06-A500, MIL-STD-461G, MIL-STD-461F
MIL-STD-461MIL-STD-461F, MIL-STD-461G
Environmental TestingPN-EN 60068-2-1, PN-EN 60068-2-2, PN-EN 60068-2-14, PN-EN 60068-2-30, PN-EN 60068-2-78, NO-06-A103, NO-06-A107
Railway EMCEN 50121-3-2, EN 50155

Certifications / Marks

Certification
CE
Pre-certification test reports
Polish defence norm (NO) test evidence
ESA partner

Industries Served

Industry
Aerospace & Defense
Military
Railway
Telecommunications
Radio & Wireless
Industrial Equipment
Consumer Electronics

Major Equipment

Equipment
Faraday cage, described as one of the largest in the region
Anechoic chamber
Climatic chamber: -40 C to +180 C, 10-98 % RH, 6 C/min temperature change rate
Conducted emissions 150 kHz - 30 MHz (NO-06-A500 / MIL-STD-461G)
Radiated emissions 100 MHz - 12 GHz (NO-06-A500 / MIL-STD-461G)
Immunity 1 - 6 GHz (NO-06-A500 / MIL-STD-461G)
EMI receiver
Spectrum analyser
LISN
CDN
ESD simulator
EFT/burst generator
Surge generator
Power frequency magnetic field coil
RF immunity amplifiers and antennas
Radio parameter measurement and antenna design bench
ELAB laboratory available for customer rental
Hardware design office and EMC troubleshooting bench