ZAMM - Zentrum fuer angewandte Messtechnik Memmingen GmbH
About
ZAMM, the Zentrum fuer angewandte Messtechnik Memmingen, is an independent EMC laboratory in the Allgaeu region of Bavaria, run by managing director and laboratory head Robert Mayr with Joerg Melcher as deputy. It holds two DAkkS accreditations to DIN EN ISO/IEC 17025 with ILAC and EA recognition: D-PL-18568-01-01 for the general EMC test suite and a separate scope D-PL-18568-01-02 covering active medical devices and in-vitro diagnostic equipment, which is the harder accreditation to obtain and the one that defines much of the laboratory's caseload. The facility is built around a 10 metre anechoic chamber complemented by a 10 metre open-area test site and a shielded cabinet, with dedicated electrostatic discharge and three-phase measurement stations for harmonic current and voltage disturbance work; emission measurement covers DC to 18 GHz and the range is extensible. Automotive component testing sits alongside the industrial and medical work, and measurements can be made on site for equipment that cannot be transported. ZAMM positions itself explicitly as a consultative laboratory - alongside accredited reporting it offers test plan development, product optimisation measurement and non-accredited testing run to a manufacturer's own specification, which suits customers iterating a design rather than closing out a certification. The customer base spans industrial electronics, medical devices and in-vitro diagnostics, automotive, machinery, environmental measurement technology, appliances, construction equipment, rail and transportation, security systems and veterinary medicine. Specialisations are medical device and IVD EMC, industrial electronics, and development-stage optimisation measurement.
Accreditations
| Accreditation |
|---|
| ISO/IEC 17025 |
| DAkkS |
| EMC Directive 2014/30/EU |
Testing Services
| Test Type | Applicable Standards |
|---|---|
| Radiated Emissions | CISPR 11, EN 55011, CISPR 32, EN 55032, CISPR 25, EN 61000-6-3, EN 61000-6-4, EN 50121-3-2, UN-ECE R10 |
| Conducted Emissions | CISPR 11, EN 55011, CISPR 32, EN 55032, CISPR 25, EN 61000-6-3, EN 61000-6-4 |
| Radiated Immunity | IEC 61000-4-3, EN 61000-4-3, EN 55035, EN 61000-6-1, EN 61000-6-2, ISO 11452-2, EN 50130-4, UN-ECE R10 |
| Conducted Immunity | IEC 61000-4-6, EN 61000-4-6, EN 55035, EN 61000-6-1, EN 61000-6-2, ISO 11452-4, EN 50130-4 |
| Radiated Susceptibility | ISO 11452-2, ISO 11452-3, IEC 61000-4-3 |
| Conducted Susceptibility | ISO 11452-4, ISO 7637-2, IEC 61000-4-6 |
| ESD | IEC 61000-4-2, EN 61000-4-2, ISO 10605 |
| EFT/Burst | IEC 61000-4-4, EN 61000-4-4 |
| Surge Immunity | IEC 61000-4-5, EN 61000-4-5 |
| Harmonics & Flicker | IEC 61000-3-2, EN 61000-3-2, IEC 61000-3-3, EN 61000-3-3, IEC 61000-3-11, IEC 61000-3-12 |
| Voltage Dips/Interrupts | IEC 61000-4-11, EN 61000-4-11, IEC 61000-4-29 |
| Power Frequency Magnetic Field | IEC 61000-4-8, EN 61000-4-8, IEC 61000-4-39 |
| Bulk Current Injection (BCI) | ISO 11452-4 |
| Pre-Compliance Testing | CISPR 11, CISPR 32, IEC 61000-4-3, EN 60601-1-2, CISPR 25 |
| Medical Device EMC | EN 60601-1-2, IEC 60601-1-2, IEC 61326-2-6, IEC 60601-1-11 |
| Automotive Component EMC | CISPR 25, ISO 11452-2, ISO 11452-4, ISO 7637-2, ISO 10605, UN-ECE R10 |
| Railway EMC | EN 50121-3-2, EN 50155 |
Certifications / Marks
| Certification |
|---|
| CE |
| UN-ECE E-mark |
Industries Served
| Industry |
|---|
| Medical Devices |
| Industrial Equipment |
| Automotive |
| Railway |
| Household Appliances |
| Energy & Power |
| Consumer Electronics |
| Agricultural & Forestry |
Major Equipment
| Equipment |
|---|
| 10 m anechoic chamber |
| 10 m open-area test site |
| Shielded cabinet |
| Measurement coverage DC - 18 GHz |
| EMI receiver |
| Spectrum analyser |
| LISN |
| CDN |
| BCI injection probes |
| Dedicated ESD test station |
| Three-phase harmonics and voltage disturbance station |
| EFT/burst generator |
| Surge generator |
| RF immunity amplifiers and antennas |
| Magnetic field coils |
| Mobile on-site measurement equipment |