EMC Latest
← Back to Labs Directory
ELMAC GmbH EMV-Labor

ELMAC GmbH EMV-Labor

Bondorf, Baden-Wuerttemberg, Germany

+49 7457 9441-0

Boschstrasse 2, Bondorf, Baden-Wuerttemberg, 71149, Germany

About

ELMAC GmbH EMV-Labor J. Buehne is an independent EMC test laboratory at Boschstrasse 2 in Bondorf, Baden-Wuerttemberg, active in EMC testing since its founding in 1990 and accredited since 1993 - originally by the Deutscher Akkreditierungsrat (DAR) and maintained continuously since, with re-assessment by DAkkS for EMC and by the Zentralstelle der Laender fuer Gesundheitsschutz (ZLG) for medical technology. The ZLG involvement is worth noting: medical device EMC accreditation in Germany runs through ZLG rather than DAkkS alone, and ELMAC holds both. Since 2001 it has been a KBA-designated Technical Service, performing E1 type approval testing and handling the approval of vehicle components with the Kraftfahrt-Bundesamt. Testing stations comprise two absorber halls with 1 m and 3 m measurement distances covering emission and immunity to 6 GHz, an open-area test site with a 10 m measurement distance, a conducted emissions station covering AC, DC, telecommunication lines and load connections from 9 kHz to 30 MHz, and two shielded rooms for conducted immunity. Published limits are specific and honest about their constraints: surge to 4 kV and voltage dips and interruptions are single-phase only, as are the two harmonics and flicker stations; burst reaches 4 kV, conducted RF runs 10 kHz to 230 MHz, ESD to 30 kV, and power-frequency magnetic field immunity is standard to 30 A/m. BCI covers 2 MHz to 250 MHz, there is an automotive station for conducted transient immunity (pulses), near-field radiated immunity from 30 kHz to 13.56 MHz, and conducted asymmetric immunity from 0 Hz to 150 kHz. Recent accreditation additions cover IEC 61000-4-16, EN 60601-1-2:2015+A1:2021 (IEC 60601-1-2 Ed. 4.1) and EN 61000-4-39:2017, with non-accredited testing offered to ETSI EN 300 220-3. Product groups covered include industrial and scientific measurement and control equipment, medical technology, IT equipment, household appliances and hand-held power tools, automotive electrical/electronic sub-assemblies (EUB), lighting, and EMVU environmental field measurement. A customer workshop area is provided so clients can make small modifications and repairs to their equipment on site.

Accreditations

Accreditation
ISO/IEC 17025
DAkkS
EMC Directive 2014/30/EU

Testing Services

Test TypeApplicable Standards
Radiated EmissionsEN 55011, EN 55032, EN 55014, EN 55015, EN 61000-6-3, EN 61000-6-4, Two absorber halls (1 m / 3 m) to 6 GHz, Open-area test site with 10 m measurement distance
Conducted EmissionsEN 55011, EN 55032, EN 55014, EN 55015, 9 kHz - 30 MHz on AC, DC, telecom lines and load connections
Radiated ImmunityEN 61000-4-3, EN 61000-6-1, EN 61000-6-2, Emission and immunity to 6 GHz, Near-field radiated immunity 30 kHz - 13.56 MHz, EN 61000-4-39:2017
Conducted ImmunityEN 61000-4-6, Conducted RF 10 kHz - 230 MHz, EN 61000-4-16 (accredited), Conducted asymmetric disturbances 0 Hz - 150 kHz
ESDEN 61000-4-2, ESD station up to 30 kV
EFT/BurstEN 61000-4-4, Burst up to 4 kV
Surge ImmunityEN 61000-4-5, Surge up to 4 kV (single-phase equipment only)
Harmonics & FlickerEN 61000-3-2, EN 61000-3-3, Two measurement stations (single-phase only)
Voltage Dips/InterruptsEN 61000-4-11 (single-phase equipment only)
Power Frequency Magnetic FieldEN 61000-4-8, 50/60 Hz, standard up to 30 A/m
Bulk Current Injection (BCI)ISO 11452-4, BCI from 2 MHz to 250 MHz
Automotive Component EMCUN-R 10 / E1 type approval, Electrical/electronic sub-assemblies (EUB), Automotive conducted transient immunity (pulses), Manufacturer-specific automotive standards
Automotive Vehicle-Level EMCE1 type approval via KBA designation, Vehicle component approval with the Kraftfahrt-Bundesamt
Medical Device EMCEN 60601-1-2:2015+A1:2021 (IEC 60601-1-2 Ed. 4.1), EN 61000-4-39:2017, ZLG-assessed medical technology accreditation
Radio Equipment TestingETSI EN 300 220-3 (non-accredited testing)
Pre-Compliance TestingCustomer workshop area for on-site modifications and repairs, Company standards and customer-specific requirements, NAMUR and other national/international specifications, Support before, during and after testing
Product SafetyEN 62233 (EMF exposure of household appliances), EN 62040-2 (UPS), EN 61326-1, EN 61547, EMVU environmental electromagnetic field measurement, DIN VDE standards

Certifications / Marks

Certification
CE
E1 type approval (KBA-designated Technical Service since 2001)
ZLG assessment for medical technology
EU Declaration of Conformity

Industries Served

Industry
Automotive
Consumer Electronics
Household Appliances
Industrial Equipment
Information Technology
Lighting Products
Medical Devices

Major Equipment

Equipment
Two absorber halls with 1 m / 3 m measurement distance (to 6 GHz)
Open-area test site with 10 m measurement distance
Conducted emissions station 9 kHz - 30 MHz (AC, DC, telecom, load connections)
Two shielded rooms for conducted immunity
Surge generator to 4 kV (single-phase)
Burst generator to 4 kV
Conducted RF system 10 kHz - 230 MHz
Voltage dip and interruption simulator (single-phase)
BCI system 2 MHz - 250 MHz
Two harmonics and flicker measurement stations (single-phase)
ESD station up to 30 kV
Magnetic field immunity coil 50/60 Hz to 30 A/m
Automotive conducted transient immunity station (pulses)
Near-field immunity system 30 kHz - 13.56 MHz
Conducted asymmetric disturbance system 0 Hz - 150 kHz
Customer workshop area