ELMAC GmbH EMV-Labor
Bondorf, Baden-Wuerttemberg, Germany
+49 7457 9441-0Boschstrasse 2, Bondorf, Baden-Wuerttemberg, 71149, Germany
About
ELMAC GmbH EMV-Labor J. Buehne is an independent EMC test laboratory at Boschstrasse 2 in Bondorf, Baden-Wuerttemberg, active in EMC testing since its founding in 1990 and accredited since 1993 - originally by the Deutscher Akkreditierungsrat (DAR) and maintained continuously since, with re-assessment by DAkkS for EMC and by the Zentralstelle der Laender fuer Gesundheitsschutz (ZLG) for medical technology. The ZLG involvement is worth noting: medical device EMC accreditation in Germany runs through ZLG rather than DAkkS alone, and ELMAC holds both. Since 2001 it has been a KBA-designated Technical Service, performing E1 type approval testing and handling the approval of vehicle components with the Kraftfahrt-Bundesamt. Testing stations comprise two absorber halls with 1 m and 3 m measurement distances covering emission and immunity to 6 GHz, an open-area test site with a 10 m measurement distance, a conducted emissions station covering AC, DC, telecommunication lines and load connections from 9 kHz to 30 MHz, and two shielded rooms for conducted immunity. Published limits are specific and honest about their constraints: surge to 4 kV and voltage dips and interruptions are single-phase only, as are the two harmonics and flicker stations; burst reaches 4 kV, conducted RF runs 10 kHz to 230 MHz, ESD to 30 kV, and power-frequency magnetic field immunity is standard to 30 A/m. BCI covers 2 MHz to 250 MHz, there is an automotive station for conducted transient immunity (pulses), near-field radiated immunity from 30 kHz to 13.56 MHz, and conducted asymmetric immunity from 0 Hz to 150 kHz. Recent accreditation additions cover IEC 61000-4-16, EN 60601-1-2:2015+A1:2021 (IEC 60601-1-2 Ed. 4.1) and EN 61000-4-39:2017, with non-accredited testing offered to ETSI EN 300 220-3. Product groups covered include industrial and scientific measurement and control equipment, medical technology, IT equipment, household appliances and hand-held power tools, automotive electrical/electronic sub-assemblies (EUB), lighting, and EMVU environmental field measurement. A customer workshop area is provided so clients can make small modifications and repairs to their equipment on site.
Accreditations
| Accreditation |
|---|
| ISO/IEC 17025 |
| DAkkS |
| EMC Directive 2014/30/EU |
Testing Services
| Test Type | Applicable Standards |
|---|---|
| Radiated Emissions | EN 55011, EN 55032, EN 55014, EN 55015, EN 61000-6-3, EN 61000-6-4, Two absorber halls (1 m / 3 m) to 6 GHz, Open-area test site with 10 m measurement distance |
| Conducted Emissions | EN 55011, EN 55032, EN 55014, EN 55015, 9 kHz - 30 MHz on AC, DC, telecom lines and load connections |
| Radiated Immunity | EN 61000-4-3, EN 61000-6-1, EN 61000-6-2, Emission and immunity to 6 GHz, Near-field radiated immunity 30 kHz - 13.56 MHz, EN 61000-4-39:2017 |
| Conducted Immunity | EN 61000-4-6, Conducted RF 10 kHz - 230 MHz, EN 61000-4-16 (accredited), Conducted asymmetric disturbances 0 Hz - 150 kHz |
| ESD | EN 61000-4-2, ESD station up to 30 kV |
| EFT/Burst | EN 61000-4-4, Burst up to 4 kV |
| Surge Immunity | EN 61000-4-5, Surge up to 4 kV (single-phase equipment only) |
| Harmonics & Flicker | EN 61000-3-2, EN 61000-3-3, Two measurement stations (single-phase only) |
| Voltage Dips/Interrupts | EN 61000-4-11 (single-phase equipment only) |
| Power Frequency Magnetic Field | EN 61000-4-8, 50/60 Hz, standard up to 30 A/m |
| Bulk Current Injection (BCI) | ISO 11452-4, BCI from 2 MHz to 250 MHz |
| Automotive Component EMC | UN-R 10 / E1 type approval, Electrical/electronic sub-assemblies (EUB), Automotive conducted transient immunity (pulses), Manufacturer-specific automotive standards |
| Automotive Vehicle-Level EMC | E1 type approval via KBA designation, Vehicle component approval with the Kraftfahrt-Bundesamt |
| Medical Device EMC | EN 60601-1-2:2015+A1:2021 (IEC 60601-1-2 Ed. 4.1), EN 61000-4-39:2017, ZLG-assessed medical technology accreditation |
| Radio Equipment Testing | ETSI EN 300 220-3 (non-accredited testing) |
| Pre-Compliance Testing | Customer workshop area for on-site modifications and repairs, Company standards and customer-specific requirements, NAMUR and other national/international specifications, Support before, during and after testing |
| Product Safety | EN 62233 (EMF exposure of household appliances), EN 62040-2 (UPS), EN 61326-1, EN 61547, EMVU environmental electromagnetic field measurement, DIN VDE standards |
Certifications / Marks
| Certification |
|---|
| CE |
| E1 type approval (KBA-designated Technical Service since 2001) |
| ZLG assessment for medical technology |
| EU Declaration of Conformity |
Industries Served
| Industry |
|---|
| Automotive |
| Consumer Electronics |
| Household Appliances |
| Industrial Equipment |
| Information Technology |
| Lighting Products |
| Medical Devices |
Major Equipment
| Equipment |
|---|
| Two absorber halls with 1 m / 3 m measurement distance (to 6 GHz) |
| Open-area test site with 10 m measurement distance |
| Conducted emissions station 9 kHz - 30 MHz (AC, DC, telecom, load connections) |
| Two shielded rooms for conducted immunity |
| Surge generator to 4 kV (single-phase) |
| Burst generator to 4 kV |
| Conducted RF system 10 kHz - 230 MHz |
| Voltage dip and interruption simulator (single-phase) |
| BCI system 2 MHz - 250 MHz |
| Two harmonics and flicker measurement stations (single-phase) |
| ESD station up to 30 kV |
| Magnetic field immunity coil 50/60 Hz to 30 A/m |
| Automotive conducted transient immunity station (pulses) |
| Near-field immunity system 30 kHz - 13.56 MHz |
| Conducted asymmetric disturbance system 0 Hz - 150 kHz |
| Customer workshop area |