
Etteplan Test Laboratory
Jyvaskyla, Central Finland, Finland
+358 10 3070Aholaidantie 3, Jyvaskyla, Central Finland, 40320, Finland
Additional locations (2)
About
Etteplan Oyj is a Finnish listed technology service company headquartered at Tekniikantie 4 D in Espoo with offices across Finland, Sweden, the Netherlands, Germany, Poland, Denmark, China and a US sales office. Its Test Laboratory operates under FINAS accreditation T298 to SFS-EN ISO/IEC 17025 across two sites, Aholaidantie 3 in Jyvaskyla and Visiokatu 4 in Tampere; the accreditation originated with Espotel Oy's Jyvaskyla EMC laboratory, which Etteplan acquired, and at the time was one of only a handful of accredited commercial EMC laboratories in Finland. What sets the laboratory apart in a directory sense is the unusual breadth of its published product-standard list, which crosses far more sectors than most single-site labs: generic immunity and emission standards (IEC/EN 61000-6-1 to -6-4 including 61000-6-7 for functional safety in industrial environments), multimedia (EN 55022/24/32/35 and the CISPR equivalents), household appliances (EN 55014-1/-2), industrial scientific and medical (EN 55011), lifts (EN 12015/12016), rolling stock and railway signalling (EN 50121-3-2, EN 50121-4), alarm systems (EN 50130-4), protection relays (EN 60255-26), welding machines (IEC/EN 60974-10), medical equipment (IEC/EN 60601-1-2), measurement and control (IEC/EN 61326-1 and -2-x), low-voltage switchgear (EN 61439-1, -7), fire and security alarm components (IEC 62599-2), home and building electronic systems (IEC/EN 63044-5-1, -2) and marine (DNV-CG-0339, IACS UR E10). RF spectrum coverage is equally deep, running from 3GPP conformance specifications for GSM, WCDMA, LTE and CDMA through the ETSI EN 301 908 and 301 511 cellular series to EN 300 328, EN 301 893, IEEE 802.11, Bluetooth SIG qualification, SRD standards below 1 GHz and below 30 MHz, EN 300 440 across 1 to 40 GHz, UWB (EN 302 065), GNSS (EN 300 413), telecom network equipment (EN 300 386) and wireless power transfer (EN 303 417). Testing uses automated measurement equipment and environments, and EMC sits alongside accredited safety, environmental and reliability, antenna and interoperability, Li-ion battery and failure analysis services under one roof, with turnkey compliance consulting and approval management available.
Accreditations
| Accreditation |
|---|
| ISO/IEC 17025 |
| EMC Directive 2014/30/EU |
| Radio Equipment Directive (RED) 2014/53/EU |
Testing Services
| Test Type | Applicable Standards |
|---|---|
| Radiated Emissions | EN 55016-2-3 / CISPR 16-2-3, EN 55011 / CISPR 11, EN 55032 / CISPR 32, EN 55014-1 / CISPR 14-1, IEC/EN 61000-6-3, IEC/EN 61000-6-4 |
| Conducted Emissions | EN 55016-2-1 / CISPR 16-2-1, EN 55011 / CISPR 11, EN 55032 / CISPR 32, EN 55014-1 / CISPR 14-1, IEC/EN 61000-6-3, IEC/EN 61000-6-4 |
| Radiated Immunity | IEC/EN 61000-4-3, EN 55024, EN 55035, EN 55014-2, IEC/EN 61000-6-1, IEC/EN 61000-6-2, IEC/EN 61000-6-7 |
| Conducted Immunity | IEC/EN 61000-4-6, IEC/EN 61000-6-1, IEC/EN 61000-6-2 |
| ESD | IEC/EN 61000-4-2 |
| EFT/Burst | IEC/EN 61000-4-4 |
| Surge Immunity | IEC/EN 61000-4-5 |
| Harmonics & Flicker | EN IEC 61000-3-2, EN 61000-3-3 |
| Voltage Dips/Interrupts | IEC/EN 61000-4-11 AC dips, IEC/EN 61000-4-29 DC dips |
| Power Frequency Magnetic Field | IEC/EN 61000-4-8, IEC/EN 61000-4-9 |
| Medical Device EMC | IEC/EN 60601-1-2 |
| Railway EMC | EN 50121-3-2 rolling stock apparatus, EN 50121-4 railway signalling |
| Radio Equipment Testing | EN 301 489-x for RED, 3GPP TS 51.010 GSM, 3GPP TS 34.121 WCDMA, 3GPP TS 36.521 LTE, 3GPP2 C.S0011-E CDMA, EN 301 511 GSM, EN 301 908-1/-2/-13 UTRA/E-UTRA, EN 300 328 WLAN/BT/SRD, EN 301 893 RLAN, IEEE 802.11, Bluetooth SIG, EN 300 220 SRD < 1 GHz, EN 300 330 SRD < 30 MHz, EN 300 440 1-40 GHz, EN 302 065-1/-2/-3 UWB, EN 300 413 GNSS, EN 300 386 telecom network equipment, EN 302 208 RFID 865-868/915-921 MHz, EN 303 417 WPT, EN 303 204 SRD network based |
| RFID Assessment | EN 302 208 low power 865-868 / 915-921 MHz radio, EN 300 330 |
| Pre-Compliance Testing | Pre-compliance EMC and RF measurement, Compliance consulting and approval services |
| Environmental Testing | Accredited environmental and reliability testing, IEC 60068-2 series, Li-ion battery performance and safety testing |
| Mechanical Testing | Vibration testing, IEC 60068-2 series, Reliability testing |
| Product Safety | Low Voltage Directive 2014/35/EU, EN 61439-1 / -7 LV switchgear, Accredited product safety testing, Safety consulting |
Certifications / Marks
| Certification |
|---|
| CE |
| EU Declaration of Conformity |
| Bluetooth SIG qualification |
| ILAC MRA |
Industries Served
| Industry |
|---|
| Automotive |
| Consumer Electronics |
| Energy & Power |
| Household Appliances |
| Industrial Equipment |
| Information Technology |
| Medical Devices |
| Multimedia |
| Radio & Wireless |
| Railway |
| Telecommunications |
Major Equipment
| Equipment |
|---|
| Accredited EMC test chamber |
| Automated EMC measurement systems |
| EMI receivers |
| LISN / artificial mains networks |
| ESD simulator |
| EFT/burst generator |
| Surge generator |
| Conducted RF immunity system |
| RF field generation system |
| Magnetic field coils |
| AC and DC voltage dip simulators |
| 3GPP cellular conformance test systems (GSM, WCDMA, LTE, CDMA) |
| WLAN / Bluetooth / NFC / LoRa / WMBUS RF test equipment |
| Antenna and IOP test facilities |
| Environmental and reliability chambers |
| Li-ion battery test facility |
| Failure analysis laboratory |
| Thermal management and automotive HVAC test facilities |




